Majestic Appliances DVB4136 manual Honeywell Comfort Control Valve ONLY, Pilot Orifice Conversion

Models: DVB4136

1 52
Download 52 pages 13.38 Kb
Page 42
Image 42
Pilot Orifice Conversion

DVB4136 Direct Vent Gas Fireplace

3.Using a 1/2” open end wrench remove the orifices. (Fig. 69)

Front Burner Orifice (Refer to Table on Page 42)

Rear Burner Orifice (Refer to Table on Page 42)

Manifold

CO130

Fig. 69 Burner orifice replacement.

4.To convert burner orifices, remove the orifices in the manifold and replace with the proper orifice listed in the table on Page 42.

5.To convert the air shutter, refer to the adjustment listed in the table. NOTE: The air shutter on the main burner is changed when converting to different gases.

8.Reassemble the burner housing assembly, the burner tube assembly and the fettle in reverse order.

Pilot Orifice Conversion

NOTE: It is not necessary to remove the pilot tube for conversion.

1.Remove pilot hood by lifting up. (Fig. 70)

2.Remove pilot orifice with Allen wrench. (Fig. 71)

3.Install conversion pilot orifice.

4.Re-install pilot hood and be sure to align with index tab. Installation is complete.

Pilot Hood

Pilot

Bracket

CO105a

Fig. 70 Remove pilot hood.

Fuel Conversion Instructions

Honeywell Comfort Control Valve ONLY

WARNING: The conversion must only be undertaken by a qualified, certified gas ap- pliance installer.

Installation Precautions

Before proceeding, turn control knob on valve to OFF and turn gas supply OFF. Turn OFF any electricity that may be going to the appliance. CAUTION: Logs may be hot!

Conversion Procedure

1.Open bottom grille to gain access to valve. Remove glass door. (Refer to “Window Frame Assembly Re- moval Section” Page 24, Fig. 47)

2.Remove logs if previously installed. CAUTION: Logs may be hot!

3.Remove and replace plug on lower right hand side of the valve; Red for LP and blue for NG. (Fig. 72)

 

Motor Top Cap

 

 

Piezo Ignitor

 

 

 

 

 

 

T

 

 

 

 

 

O

 

 

 

 

IL

 

 

 

 

 

P

 

OFF

 

 

 

 

 

 

 

 

 

 

N

 

 

 

 

 

 

O•

 

 

 

 

LOCAL

REMOTE

 

 

LED

 

 

 

 

 

 

 

 

 

 

LED

 

Local/

 

Pilotstat

 

 

Plug

 

Remote Switch

Knob

 

 

 

 

 

Antenna

 

 

 

 

 

 

FP1037

 

 

 

 

 

 

Fig. 72

Comfort control valve.

 

 

 

 

4.Remove motor top cap. Depress and turn center plunger until arrow points to correct screw. Red for LP and Blue for NG. NOTE: Plunger will “snap” into NG position when arrow is close to blue screw. It will not “snap” at LP (Red) position. (Fig. 73)

Index Tab

Allen Wrench

Snap Ring

 

Center

Plunger

Blue - NG Honeywell Comfort Control Valve ONLYInstallation Precautions Red - LP

Motor Top Cap

LOCALConversion Procedure

FP1037b

CO106a

Fig. 71 Remove pilot orifice.

42

Fig. 73 Depress and turn center plunger.

Burner Orifice Conversion

Refer to Burner Orifice Conversion on Page 40.

20012322

Page 42
Image 42
Majestic Appliances Honeywell Comfort Control Valve ONLY, DVB4136 Direct Vent Gas Fireplace, Pilot Orifice Conversion