Majestic Appliances DVB4136 manual Below Grade Installation, Vertical Through-the-RoofApplication

Models: DVB4136

1 52
Download 52 pages 13.38 Kb
Page 21
Image 21
Below Grade Installation

Below Grade Installation

When it is not possible to meet the required vent ter- minal clearances of 12” (305 mm) above grade level, a snorkel kit is recommended. It allows installation depth down to 7” (178 mm) below grade level. The 7” (178

mm)is measured from the center of the horizontal vent pipe as it penetrates through the wall.

Ensure the sidewall venting clearances are ob- served. If venting system is installed below ground, we recommend a window well with adequate and proper drainage to be installed around the termina- tion area.

DVB4136 Direct Vent Gas Fireplace

Do not back fill around snorkel.

A clearance of at least 4” must be main- tained between the snorkel and the soil.

If the foundation is recessed, use recess brackets (not supplied) for securing lower portion of the snorkel. Fas- ten brackets to wall first, then secure to snorkel with self drilling #8 x 1/2 sheet metal screws. It will be necessary to extend vent pipes out as far as the protruding wall face. (Fig. 38)

If installing a snorkel, a minimum 24” (610 mm) vertical rise is necessary. The maximum horizontal run with the 24” vertical pipe is 36” (914 mm). This measurement is taken from the collar of the fireplace (or transition elbow) to the face of the exterior wall. See the Sidewall Venting Graph for extended horizontal run if the vertical exceeds 24” (610 mm).

1.

Establish vent hole through the wall (Fig. 31)

2.

Remove soil to a depth of approximately 16”

 

(406mm) below base of snorkel. Install drain pipe.

Foundation

Recess

Watertight

Seal Around

PIpe

Snorkel

Wall Screws

Sheet Metal Screws

BG401

 

Install window well (not supplied). Refill hole with 12”

 

(305 mm) of coarse gravel leaving a clearance of ap-

 

proximately 4” (102 mm) below snorkel. (Fig. 37)

3.

Install vent system.

4.

Ensure a watertight seal is made around the vent

 

pipe coming through the wall.

5.

Apply high temperature sealant caulking (supplied)

 

around the 4” and 7” snorkel collars.

6.

Slide the snorkel into the vent pipes and secure to

 

the wall.

7.

Level the soil so as to maintain a 4” (102 mm) clear-

 

ance below snorkel. (Fig. 37)

Fig. 38 Snorkel installation, recessed foundation.

Vertical Through-the-Roof Application

This gas fireplace has been approved for:

Vertical installations up to 40’ (12 m) in height. Up to a 10’ (3 m) horizontal vent run can be installed within the vent system using a maximum of two 90° elbows. (Fig. 39)

Up to two 45° elbows may be used within the hori- zontal run. For each 45° elbow used on the horizon- tal plane, the maximum horizontal length must be reduced by 18” (450 mm).

Zero Clearance Sleeve

(if required)

Firestop

7” Pipe

24” (610mm) Minimum*

Screws

7TDVSNORK

(Snorkel)

4” (102mm) Clearance Min.

Window

Well

Vertical Through-the-Roof Application Gravel

Manual background Drain

Manual background Foundation Wall

*A minimum of 24” (610 mm) vertical pipe must be installed when using the 7TDVSNORK Kit.

Example: Maximum horizontal length:

No elbows

= 10’ (3 m)

1 x 45° elbow

= 8.5’ (2.6 m)

2 x 45° elbows = 7’ (2.1 m)

A minimum of an 8’ (2.5 m) vertical rise is required.

Two sets of 45° elbow offsets may be used within the vertical sections. From 0 to a maximum of 8’ (2.5 m) of vent pipe can be used between elbows. (Fig. 40)

7DVCS supports offsets. (Fig. 42) This application will require that you first determine the roof pitch and use the appropriate starter kit. (Refer to Venting Components List)

The maximum angular variation allowed in the sys- tem is 270°. (Fig. 40)

The minimum height of the vent above the highest point of penetration through the roof is 2’ (610 mm). (Fig. 43) Refer to note 2, Page 14.