Majestic Appliances manual General Venting, DVB4136 Direct Vent Gas Fireplace, 20012322

Models: DVB4136

1 52
Download 52 pages 13.38 Kb
Page 12
Image 12
General Venting

DVB4136 Direct Vent Gas Fireplace

General Venting

Your fireplace is approved to be vented either through the side wall, or vertical through the roof.

Only CFM Corporation venting components spe- cifically approved and labelled for this fireplace may be used.

Venting terminals shall not be recessed into a wall or siding.

Horizontal venting which incorporates the twist lock pipe must be installed on a level plane without an inclining or declining slope.

Horizontal venting which incorporates the use of flex venting shall have an inclining slope from the unit of 1” (25 mm) per 24” (610 mm).

There must not be any obstruction such as bushes, gar- den sheds, fences, decks or utility buildings within 24” (610 mm) from the front of the termination hood.

Do not locate termination hood where excessive snow or ice build up may occur. Be sure to check vent termi- nation area after snow falls, and clear to prevent ac- cidental blockage of venting system. When using snow blowers, make sure snow is not directed towards vent termination area.

Location of Vent Termination

It is imperative the vent termination be located observ- ing the minimum clearances as shown on following page.

12

20012322

Page 12
Image 12
Majestic Appliances manual General Venting, DVB4136 Direct Vent Gas Fireplace, Location of Vent Termination, 20012322