Sears 919.727121 owner manual Maintenance, Check Valve Replacement Safety Valve Inspection

Page 11

MAINTENANCE

UNIT CYCLES AUTOMATICALLY WHEN POWER IS ON. WHEN DOING MAINTENANCE, YOU MAY BE EXPOSED TO VOLTAGE SOURCES, COMPRESSED AIR OR MOVING PARTS. PERSONAL INJURIES CAN OCCUR. BEFORE PERFORMING ANY MAINTENANCE OR REPAIR, UNPLUG THE COMPRESSOR AND BLEED OFF ALL AIR PRESSURE.

ALL MAINTENANCE AND REPAIR OPERATIONS NOT LISTED MUST BE DONE BY QUALIFIED SERVICE PERSONNEL.

Check Valve - Replacement

Safety Valve - Inspection

 

Before servicing:

Unplug or disconnect electrical supply to compressor.

Bleed tank of pressure.

Allow compressor to cool.

1.Release all air pressure from air tank and unplug outfit.

2.Loosen the bottom nut and move the outlet tube to the side.

3.Unscrew the check valve (turn counterclockwise) using a socket wrench.

4.Check that the valve disc moves freely inside the check valve and that the spring holds the disc in the upper, closed position. The check valve may be cleaned with a solvent, such as paint and varnish remover.

5.Apply sealant to the check valve threads. Reinstall the check valve (turn clockwise).

6.Replace the outlet tube and tighten the bottom nut.

If the safety valve does not work properly, over-pressurization may occur, causing air tank rupture or an explosion. Before starting compressor, pull the ring on the safety valve to make sure that the safety valve operates freely. If the valve is stuck or does not operate smoothly, it must be replaced with the same type of valve.

Storage

Before you store the air compressor, make sure you do the following:

1.Review the “Maintenance” and "Operating Procedures" sections and perform maintenance as necessary. Be sure to drain water from the air tank.

2.Protect the electrical cord and air hose from damage (such as being stepped on or run over). Wind them loosely around the compressor handle.

Store the air compressor in a clean and dry location.

11 — ENG

D20414 Rev. 0 2/15/00

Image 11
Contents Model No Safety Guidelines Definitions Table of ContentsRisk of Bursting Important Safety InstructionsHazard Risk of Explosion or FireRisk of Electrical Shock Risk from Flying ObjectsRisk to Breathing Risk of Falling Risk of Property Damage When Transporting CompressorRisk from Moving Parts Risk of BurnsGlossary Specification ChartGeneral Information Description of Operation Tools Needed for AssemblyInstallation and BREAK-IN Procedures AssemblyGrounding Instructions When you are finished Operating ProceduresCheck Valve Replacement Safety Valve Inspection MaintenanceProblem Cause Correction Troubleshooting GuideTroubleshooting Guide Permanently Lubricated Tank Mounted AIR Compressor Modèle no Garantie Complète DE UN AN SUR LES Compresseurs D’AIR Table DES MatièresRisque D’ÉCLATEMENT Risque D’EXPLOSION OU D’INCENDIERisque DE Choc Électrique Risque DE Projection D’OBJETSRisque PAR Inhalation Risque DE Chute Risque Relié AUX Pièces MobilesRisque DE Brûlures Tableau DES Spécifications Renseignements GénérauxLexique Outils Requis À L’INSTALLATION Description DU Mode OpérationnelAssemblage Installation ET Procédures DE Mise EN RouteProcédures de mise en route Directives DE Mise a LA TerreUne fois que vous avez terminé Procédures OpérationnellesEntretien Soupape de retenue RemplacementProblème Cause Correction Guide DE DÉ PannageAccuse toujours une fuite, remplacez-la Modèle no