Models 2603, 2621, and 2635 Getting Started Guide | 6 • WAN Services |
|
|
WAN Services
Configuring the IPLink Series 2603 for E1 Operation
Web Configuration. Launch Internet Explorer or similar web browser, type the IP address of the 2603, enter username superuser and password superuser. From the main page click on the T1/E1 > Configuration. (See figure 26.)
Figure 26. E1 port configuration
Time Slot Select. For unframed E1 service (Clear Channel) go to the “Line Option” parameter and select “Clear Channel E1 (G.703).” For a full framed E1 enter
Line Options: Choose from Clear Channel E1(G.703) or Channelized E1(G.703/G.704). Consult with your service provider which option is required.
Line Code: Choose from AMI or HDB3. Most E1 applications use HDB3.
Line Build Out: Select 120 Ohms if the E1 connection is made via the
FDL Mode: FDL is a T1 application, therefore select ‘Fdl- none’ for E1 applications.
Clocking Mode: Options are Internal or Receive Recover Clock (network). In most applications clocking for the 2603 will be derived from the E1 network, set the unit for Receive Recover unless instructed otherwise by your service provider.
Idle code: Options are Enabled or Disabled. When idle code is Enabled, the 2603 inserts idle codes (7E hex) on unused timeslots. Set this option to Disabled unless instructed otherwise.
Power Down: Options are Normal and Powerdown. When powered down, the E1 will put high impedance on the input and output lines to protect the
WAN Services | 51 |