Carrier KC_233P Secure Shutters, Reinstalling Front Panel Assembly, Complete the installation

Page 8

Solid Piece Wood (If required)

A06542

Fig. 13 ---Solid Piece of Wood Placement

Window Sash

Window Sash

Sealing Strip

A06543

Fig. 14 ---Seal Strip Adhesion

Step 6 Installation of the cabinet

A.Align one hole in the bottom of the cabinet with one hole in the bracket assembly. Secure the cabinet to the bracket using

(3)1/4” screws provided. Repeat the same procedure on the opposite side of the cabinet. See (Fig. 15).

B.Ensure the ”L” shaped mounting channel is positioned in front of the sash. The bottom channel of the cabinet should be positioned in the track provided on the bracket assembly. Pull the window down until it rests just behind the front of the ”L” shaped mounting channel. See (Fig. 16).

C.Check to make sure that the cabinet is slanted slightly downward on the outside. If necessary, re-adjust support bracket as shown in (Fig. 12).

Step 7 Secure Shutters

A. Carefully slide the air conditioner back into the cabinet. (Please seek assistance for this procedure).

B. Reinstall the slide-out-chassis security screws (removed earlier) on both sides of the cabinet (see Fig. 12). Secure the top of the frames to the window sash with (2) 3/4” screws.

C.Now, secure bottom frame of shutters using one shutter clamp and one 3/4” screw on each side (see Fig. 12).

Step 8 Reinstalling Front Panel Assembly

A.Position the front panel on the cabinet starting at the top. The front panel lock tabs must be inserted into the retaining slots in the cabinet. Repeat this procedure on all sides.

B.Secure the front grille to the cabinet using the Philips screws removed earlier (see Fig. 6).

Step 9 Complete the installation

A.Cut the foam to fit the opening between the top of the inside and outside window (see Fig. 18).

B.Some installations may require additional sealing around the window and air conditioner. Check for any air leaks and seal where necessary.

C. In very humid areas, the water removal may be excessive enough to overflow the unit or increase the noise of the air conditioner. If this occurs, you may wish to attach a drain hose (not included) to the drain plug allowing condensations to run off conveniently (see Fig. 19).

NOTE: Fresh Air ventilation is usually kept in the closed position. Use only when clearing smoke and/or odors from the room. Pull to open (see Fig. 20).

1/4" Screws

A06544

Fig. 15 ---Secure the Cabinet

Window Sash

"L"Shaped Seal

Mounting

Channel

A06545

Fig. 16 ---Mounting Channel

3/4" screws

"L"Shaped Seal

Mounting

Channel

Security Screw

Coil

A06546

Fig. 17 ---Security Screw Detail

Foam

A06547

Fig. 18 ---Foam Fitting

8

Image 8
Contents Remote Control Unit Date InstalledTable of Contents Airc onditioner Safety ConsiderationsIntroduction 23K Cooling only including models Electrical SpecificationsElectrical Shock Hazard Unit Operation Hazard Tips Before InstallationPower Supply Cord Installation Instructions Personal INJURY/UNIT Operation HazardSelect the Best Location GroundAssembly of the side shutters curtains to the cabinet Unit Damage HazardSecure Shutters Reinstalling Front Panel AssemblyComplete the installation Storm Window Applications Drain HoseWall Installation Wall Installation LocationMasonry Construction Personal Injury HazardOperating Instructions Remote Control How to UseCare and Maintenance Troubleshooting GuideCleaning the Air Filter Air Filter RemovalIf Your Unit does not WORK, Follow These Steps in Order Carrier Room AIR Conditioner Full WarrantyCarrier will not be Responsible for Catalog NoOMKCKH---2 Instrucciones de Instalación y funcionamiento Contenido Precauciones DE Seguridad IntroducciónNota 10K-14K modelos Sólo con enfriamiento 23K Especificaciones EléctricasRiesgo DE Descarga Eléctrica Cable Eléctrico Consejos Para Antes DE LA InstalaciónRiesgo DE Operación Errática DE LA Unidad Instrucciones DE Instalación Riesgo DE Operación Errática DE LA Unidad Y LesionesPaso 1-Seleccione la mejor ubicación posible Aperturas de la ventanaSerpentín Chasis Tirador Paso 3-Montaje del canal inferior y superior en la cajaRiesgo DE Daño a LA Unidad Paso 6-Instalación de la cajaPaso 7-Fije las persianas Paso 8-Vuelva a instalar el panel frontalInstalaciones CON Contraventana El instalador tendrá que suministrar y cortar la tablaInstalación EN LA Pared 8 pulg. mínInstalación del marco Riesgo DE Lesiones PersonalesConstrucción EN Mampostería Instrucciones DE FuncionamientoMando a distancia Modo de empleoSolución DE Problemas Cuidado Y MantenimientoDesmontaje del filtro de aire Limpieza del filtro de aireCarrier no Será Responsable POR Nº de catálogo OMKCKH---2 MOT D’ACCUEIL AU Propriétaire DE CET Équipement Table DES Matières Pour Votre Sécurité IntroductionCaractéristiques Électriques Risque D’ÉLECTROCUTIONVis 3/4 po Vis 1/4 po RondelleRail inférieur Cordon ÉlectriqueÉtape 1-Choix de l’endroit le plus approprié Latéral Obstacle SolVis Philips côté droit Étape 3-Pose des rails supérieur et inférieur du boîtierÉtape 4-Pose des volets latéraux rideaux au boîtier Étape 5-Pose des supports de montage et du premier jointÉtape 6-Pose du boîtier Étape 7-Pose des voletsÉtape 8-Pose du panneau avant Étape 9-CalfeutrageIntercalaire Fourni PAR Linstallateur Installation SUR UN ContrechâssisInstallation Murale A06740Pose du cadre Risque DE Blessures CorporellesMode D’EMPLOI MaçonnerieTélécommande Mode d’emploi de la télécommandeEntretien ET Maintenance Dépose du filtreNettoyage du filtre à air Entretien de fin de saisonCarrier NE Pourra Être Tenu Responsable DE

KC_141P, KH_233P, KC_223P, KC_233P, KC_183P specifications

Carrier has made significant strides in the HVAC industry with its innovative series of air conditioning systems, particularly the KH_123P, KC_183P, KC_233P, KC_223P, and KH_233P models. These models are a testament to Carrier's commitment to delivering advanced technology, energy efficiency, and enhanced comfort in climate control.

The KH_123P model is a compact ductless system that provides effective cooling and heating solutions for residential spaces. With its sleek design, it seamlessly integrates into any home decor. The unit features advanced inverter technology, allowing for variable speed operation that adjusts to the cooling demand, significantly reducing energy consumption. It also boasts low ambient cooling capability, making it ideal for use in various climates.

Next, the KC_183P and KC_233P models are designed for medium to large spaces, providing powerful climate control with a focus on quiet operation. Both models are equipped with high-efficiency scroll compressors that ensure reliable performance while minimizing noise levels. Additionally, these units feature multiple fan speeds and advanced air filtration systems, which improve indoor air quality by capturing dust, allergens, and other pollutants.

The KC_223P model stands out for its smart technology integration. It supports Wi-Fi connectivity, allowing users to control the system remotely via a smartphone app. This feature enables scheduling, temperature adjustments, and monitoring of energy usage from virtually anywhere. The KC_223P also includes precise temperature control and zoning capability, creating comfort zones tailored to individual preferences throughout the home or office.

The KH_233P model further enhances energy efficiency with its EcoMode setting, which optimizes performance for lower energy consumption during periods of low activity. This model is also equipped with advanced diagnostics and self-cleaning functions, reducing maintenance needs and extending the unit's lifespan.

All of these Carrier models come with a robust warranty and are backed by Carrier’s storied reputation for quality and innovation. With their blend of advanced technology, efficiency, and user-friendly features, the KH_123P, KC_183P, KC_233P, KC_223P, and KH_233P systems are stellar choices for anyone looking to enhance their indoor climate comfort. Carrier continues to set the standard in the HVAC sector through these versatile and high-performing solutions.