Carrier KC_141P, KH_123P, KC_183P, KC_233P manual Electrical Specifications, Electrical Shock Hazard

Page 4

ELECTRICAL SPECIFICATIONS

1.All wiring must comply with local and national electrical codes and must be installed by a licenced electrician. If you have any questions regarding the following instructions, contact a licenced electrician.

2.Check available power supply and resolve any wiring problems BEFORE installing and operating this unit.

3.For your safety and protection, this unit is grounded through the power cord when plugged into a matching wall outlet. If you are not sure whether your wall outlet is properly grounded, please consult a licenced electrician.

4.The wall outlet (3-pin) must match the plug (3-pin) on the power cord supplied with the unit. DO NOT use plug adapters or extension cords. See (Table 1) for receptacle and fuse information.

5.The rating plate on the unit contains electrical and other technical data. The rating plate is located on the right side of the unit. Make sure to use the correct power supply according to the rating plate of your air conditioner.

!WARNING

ELECTRICAL SHOCK HAZARD

Failure to follow this warning could result in personal injury or death and/or property damage.

Shut off electrical power to unit before installing or servicing.

If the air conditioner has a serial plate rating of 115 volts and up to and including 7.5 amps, the unit maybe on a fuse or circuit breaker with other devices. However, the maximum amps on all devices for that fuse or circuit breaker can not exceed the amps of the fuse for the circuit breaker.

If the air conditioner has a serial plate rating of 115 volts and greater than 7.5 amps it must have its own fuse or circuit breaker, and no other device or unit should be operated on the fuse or circuit breaker.

If the air conditioner has a serial plate rating of 230 volts, it must have its own fuse or circuit breaker, and no other device or unit should be operated on the fuse or circuit breaker.

 

RECEPTACLE AND FUSE TYPES

 

 

COOLING CAPACITY

10K---14K

18K(Cooling only)

23K

18K---23K

(Cooling only)

10K---12K(With heating)

(Cooling only)

(With heating)

 

RATED VOLTS

125

250

250

250

AMPS

15

15

20

30

WALL OUTLET

 

 

 

 

 

 

 

 

 

FUSE SIZE

15

15

20

30

NOTE: 10K-14K (Cooling only) including models

23K (Cooling only) including models

18K (Cooling only) including models

18K-23K (with Heating) including models

10K-12K (with Heating) including models

 

 

 

NOTE: Check rating plate on your specific model for exact receptacle and fuse type.

4

Image 4
Contents Remote Control Unit Date InstalledTable of Contents Introduction Safety ConsiderationsAirc onditioner Electrical Shock Hazard Electrical Specifications23K Cooling only including models Power Supply Cord Tips Before InstallationUnit Operation Hazard Installation Instructions Personal INJURY/UNIT Operation HazardSelect the Best Location GroundAssembly of the side shutters curtains to the cabinet Unit Damage HazardComplete the installation Reinstalling Front Panel AssemblySecure Shutters Storm Window Applications Drain HoseWall Installation Wall Installation LocationMasonry Construction Personal Injury HazardOperating Instructions Remote Control How to UseCare and Maintenance Troubleshooting GuideCleaning the Air Filter Air Filter RemovalCarrier will not be Responsible for Carrier Room AIR Conditioner Full WarrantyIf Your Unit does not WORK, Follow These Steps in Order Catalog NoOMKCKH---2 Instrucciones de Instalación y funcionamiento Contenido Precauciones DE Seguridad IntroducciónRiesgo DE Descarga Eléctrica Especificaciones EléctricasNota 10K-14K modelos Sólo con enfriamiento 23K Riesgo DE Operación Errática DE LA Unidad Consejos Para Antes DE LA InstalaciónCable Eléctrico Instrucciones DE Instalación Riesgo DE Operación Errática DE LA Unidad Y LesionesPaso 1-Seleccione la mejor ubicación posible Aperturas de la ventanaSerpentín Chasis Tirador Paso 3-Montaje del canal inferior y superior en la cajaRiesgo DE Daño a LA Unidad Paso 6-Instalación de la cajaPaso 7-Fije las persianas Paso 8-Vuelva a instalar el panel frontalInstalaciones CON Contraventana El instalador tendrá que suministrar y cortar la tablaInstalación EN LA Pared 8 pulg. mínInstalación del marco Riesgo DE Lesiones PersonalesConstrucción EN Mampostería Instrucciones DE FuncionamientoMando a distancia Modo de empleoSolución DE Problemas Cuidado Y MantenimientoDesmontaje del filtro de aire Limpieza del filtro de aireCarrier no Será Responsable POR Nº de catálogo OMKCKH---2 MOT D’ACCUEIL AU Propriétaire DE CET Équipement Table DES Matières Pour Votre Sécurité IntroductionCaractéristiques Électriques Risque D’ÉLECTROCUTIONVis 3/4 po Vis 1/4 po RondelleRail inférieur Cordon ÉlectriqueÉtape 1-Choix de l’endroit le plus approprié Latéral Obstacle SolVis Philips côté droit Étape 3-Pose des rails supérieur et inférieur du boîtierÉtape 4-Pose des volets latéraux rideaux au boîtier Étape 5-Pose des supports de montage et du premier jointÉtape 6-Pose du boîtier Étape 7-Pose des voletsÉtape 8-Pose du panneau avant Étape 9-CalfeutrageIntercalaire Fourni PAR Linstallateur Installation SUR UN ContrechâssisInstallation Murale A06740Pose du cadre Risque DE Blessures CorporellesMode D’EMPLOI MaçonnerieTélécommande Mode d’emploi de la télécommandeEntretien ET Maintenance Dépose du filtreNettoyage du filtre à air Entretien de fin de saisonCarrier NE Pourra Être Tenu Responsable DE

KC_141P, KH_233P, KC_223P, KC_233P, KC_183P specifications

Carrier has made significant strides in the HVAC industry with its innovative series of air conditioning systems, particularly the KH_123P, KC_183P, KC_233P, KC_223P, and KH_233P models. These models are a testament to Carrier's commitment to delivering advanced technology, energy efficiency, and enhanced comfort in climate control.

The KH_123P model is a compact ductless system that provides effective cooling and heating solutions for residential spaces. With its sleek design, it seamlessly integrates into any home decor. The unit features advanced inverter technology, allowing for variable speed operation that adjusts to the cooling demand, significantly reducing energy consumption. It also boasts low ambient cooling capability, making it ideal for use in various climates.

Next, the KC_183P and KC_233P models are designed for medium to large spaces, providing powerful climate control with a focus on quiet operation. Both models are equipped with high-efficiency scroll compressors that ensure reliable performance while minimizing noise levels. Additionally, these units feature multiple fan speeds and advanced air filtration systems, which improve indoor air quality by capturing dust, allergens, and other pollutants.

The KC_223P model stands out for its smart technology integration. It supports Wi-Fi connectivity, allowing users to control the system remotely via a smartphone app. This feature enables scheduling, temperature adjustments, and monitoring of energy usage from virtually anywhere. The KC_223P also includes precise temperature control and zoning capability, creating comfort zones tailored to individual preferences throughout the home or office.

The KH_233P model further enhances energy efficiency with its EcoMode setting, which optimizes performance for lower energy consumption during periods of low activity. This model is also equipped with advanced diagnostics and self-cleaning functions, reducing maintenance needs and extending the unit's lifespan.

All of these Carrier models come with a robust warranty and are backed by Carrier’s storied reputation for quality and innovation. With their blend of advanced technology, efficiency, and user-friendly features, the KH_123P, KC_183P, KC_233P, KC_223P, and KH_233P systems are stellar choices for anyone looking to enhance their indoor climate comfort. Carrier continues to set the standard in the HVAC sector through these versatile and high-performing solutions.