Intel SBX82 manual Light Path Diagnostics table

Page 80

NMI

MIS

SBRD

TEMP

Power is available to relight the Light Path Diagnostics LEDs for a short period of time after the blade server is removed from the SBCE unit. During that time, you can relight the Light Path DIagnostics LEDS for up to 25 seconds or less, depending on the number of LEDs that are lit and the length of time the blade server is removed from the SBCE unit.

Light Path Diagnostics table

Use Table 7 to help determine the cause of the error and the action you should take.

Power is available to relight the Light Path Diagnostics LEDs for a small period of time after the blade server is removed from the SBCE unit. During that period of time, you can relight the Light Path Diagnostics LEDs for a maximum of 25 seconds (or less, depending on the number of LEDs that are lit and the length of time the blade server is removed from the SBCE unit) by pressing the Light Path Diagnostics button. The Light Path Diagnostics power present LED (CR111) lights when the Light Path Diagnostics button is pressed if power is available to relight the blade-error LEDs. If the Light Path Diagnostics power present LED does not light when the Light Path Diagnostics button is pressed, no power is available to light the blade-error LEDs, and they will be unable to provide any diagnostic information.

66

Intel Server Compute Blade SBX82 Installation and User’s Guide

Image 80
Contents Intel Server Compute Blade SBX82 Disclaimer Contents Configuring the blade server Safety and regulatory information General Safety Electrical SafetyVii Handling electrostatic discharge-sensitive devices To Connect To Disconnect Use safe practices when lifting Regulatory specifications and disclaimers Safety complianceElectromagnetic compatibility notices USA Electromagnetic compatibility ECMXiii Electromagnetic compatibility notices InternationalJapan EMC Compatibility RRL Korea English translation of the notice above Device User’s InformationPage Blade server release levers Label placement on the Sbce unit Features and specifications Reliability, availability, and serviceability featuresIntel Server Compute Blade SBX82 features Intel Server Compute Blade SBX82 specifications Power throttlingService Processor Processor Size Electrical InputEnvironment Memory Integrated functionsMajor components of the blade server Related publicationsPage Page Using power, controls, jumpers, switches, and indicators Turning on the blade serverTurning off the blade server Understanding the control panel and LEDs NumLock NumLock bladeservernumber Enter Using system board switches System board illustrationUsing switch block 2 SW2 Switch block 2 SW2 and settingsNMI MIS Sbrd Temp MIS Handling static-sensitive devices Installation guidelinesSystem reliability considerations Installing and removing the blade server from the Sbce unit Opening the blade server coverRemoving the blade server bezel assembly StatementInstalling a Scsi hard disk drive Installing a Scsi driveInstalling memory modules Removing a Scsi hard disk driveInstalling Dimms Installing an additional processor Page Lever fully open Lever closed Installing an I/O expansion card Installing a small form-factor expansion card Installing a small form-factor I/O card in the blade server Installing a standard form-factor expansion card IInstalling the Intel Blade Server Scsi Expansion Module SbescsiInstalling a Scsi storage expansion unit Cover pins Scsi IDs for the hard disk drives in the expansion unit Installing a Scsi disk drive Page Opening the expansion unit cover Installing an I/O expansion card Installing an I/O expansion card in the expansion unit Replacing the battery Battery location Completing the installation Installing the blade server bezel assembly Closing the blade server cover Installing the blade server in the Sbce unit Updating your blade server configuration Input/output connectors and devices Configuration/Setup Utility menu choices Using the Configuration/Setup Utility programStarting the Configuration/Setup Utility program System Information Product DataDevices and I/O Ports Remote Console RedirectionAdvanced Setup Memory SettingsBaseboard Management Controller BMC Settings BMC Network ConfigurationUsing passwords Using the PXE boot agent utility program Firmware updatesConfiguring the Gigabit Ethernet controllers Configuring a Scsi RAID array Blade server Ethernet controller enumerationUsing the LSI Logic Configuration Utility program Diagnostic tools overview Troubleshooting chartsDiagnostic programs and error messages Light Path Diagnostics featurePost beep code descriptions Repeating long beepsPost error messages Abbreviated list of Post error messagesAbbreviated list of Post error messages Processor problems Troubleshooting chartsMemory problems Monitor problems Mm 3Mouse problems Network connection problemsOption problems Power problemsLight path diagnostics Service processor problemsDiagnosing problems using Light Path Diagnostics Light Path Diagnostics LEDsLight Path Diagnostics table Light path diagnostics Page Getting help and information from the World Wide Web Using the documentationBefore you call Page Index Password Scsi RAID