Intel SBX82 manual Light path diagnostics

Page 81

Table 7. Light path diagnostics

LED

Problem

Action

 

 

 

None

An error has occurred and cannot

Check the system error log in the management

 

be isolated, or the service processor

module for more information about the error.

 

has failed. The error is not

 

 

represented by a light path

 

 

diagnostic LED.

 

 

 

 

DIMM x error

A memory error has occurred.

Replace the failing DIMM, indicated by the lit DIMM

 

 

failure LED.

 

 

Multiple DIMM LEDs do not necessarily indicate

 

 

multiple DIMM failures. If more than one DIMM LED

 

 

is lit, reseat or replace one DIMM at a time until the

 

 

error goes away. Check the system error log in the

 

 

management module for information about the

 

 

error.

 

 

 

Processor x

The processor has failed.

Make sure that the processor that is indicated by

error

 

the lit LED is installed correctly (see “Installing an

 

 

additional processor” on page 25 for installation

 

 

instructions).

 

 

 

Temperature

The system temperature has

• Determine whether a blower on the SBCE unit

error

exceeded a threshold level.

has failed. If it has, replace the fan.

 

 

• Make sure that the room temperature is not too

 

 

high (see “Features and specifications” on

 

 

page 4 for temperature information).

 

 

 

System board

The system board has failed.

Replace the blade server cover, reinsert the blade

error

 

server in the SBCE unit, and then restart the server.

 

 

 

NMI error

The system board has failed.

1. Replace the blade server cover, reinsert the

 

 

blade server in the SBCE unit, and then restart

 

 

the server.

 

 

2. Check the system error log in the management

 

 

module for information about the error.

 

 

 

Processor

The processors do not match.

Make sure that processors 1 and 2 have the same

mismatch

 

cache size and type and the same clock speed.

 

 

Internal and external clock frequencies must be

 

 

identical.

 

 

 

67

Image 81
Contents Intel Server Compute Blade SBX82 Disclaimer Contents Configuring the blade server Safety and regulatory information Electrical Safety General SafetyVii Handling electrostatic discharge-sensitive devices To Connect To Disconnect Use safe practices when lifting Safety compliance Regulatory specifications and disclaimersElectromagnetic compatibility ECM Electromagnetic compatibility notices USAElectromagnetic compatibility notices International Japan EMC CompatibilityXiii Device User’s Information RRL Korea English translation of the notice abovePage Blade server release levers Label placement on the Sbce unit Reliability, availability, and serviceability features Features and specificationsIntel Server Compute Blade SBX82 features Power throttling Intel Server Compute Blade SBX82 specificationsProcessor Size Electrical Input Service ProcessorEnvironment Memory Integrated functionsRelated publications Major components of the blade serverPage Page Turning on the blade server Using power, controls, jumpers, switches, and indicatorsTurning off the blade server Understanding the control panel and LEDs NumLock NumLock bladeservernumber Enter System board illustration Using system board switchesSwitch block 2 SW2 and settings Using switch block 2 SW2NMI MIS Sbrd Temp MIS Installation guidelines System reliability considerationsHandling static-sensitive devices Opening the blade server cover Installing and removing the blade server from the Sbce unitStatement Removing the blade server bezel assemblyInstalling a Scsi drive Installing a Scsi hard disk driveRemoving a Scsi hard disk drive Installing memory modulesInstalling Dimms Installing an additional processor Page Lever fully open Lever closed Installing an I/O expansion card Installing a small form-factor expansion card Installing a small form-factor I/O card in the blade server Installing a standard form-factor expansion card Sbescsi IInstalling the Intel Blade Server Scsi Expansion ModuleInstalling a Scsi storage expansion unit Cover pins Scsi IDs for the hard disk drives in the expansion unit Installing a Scsi disk drive Page Opening the expansion unit cover Installing an I/O expansion card Installing an I/O expansion card in the expansion unit Replacing the battery Battery location Completing the installation Installing the blade server bezel assembly Closing the blade server cover Installing the blade server in the Sbce unit Updating your blade server configuration Input/output connectors and devices Using the Configuration/Setup Utility program Starting the Configuration/Setup Utility programConfiguration/Setup Utility menu choices Product Data System InformationDevices and I/O Ports Remote Console RedirectionMemory Settings Advanced SetupBaseboard Management Controller BMC Settings BMC Network ConfigurationUsing passwords Firmware updates Using the PXE boot agent utility programConfiguring the Gigabit Ethernet controllers Blade server Ethernet controller enumeration Configuring a Scsi RAID arrayUsing the LSI Logic Configuration Utility program Troubleshooting charts Diagnostic tools overviewDiagnostic programs and error messages Light Path Diagnostics featureRepeating long beeps Post beep code descriptionsAbbreviated list of Post error messages Post error messagesAbbreviated list of Post error messages Troubleshooting charts Memory problemsProcessor problems Mm 3 Monitor problemsNetwork connection problems Mouse problemsPower problems Option problemsService processor problems Light path diagnosticsDiagnosing problems using Light Path Diagnostics Light Path Diagnostics LEDsLight Path Diagnostics table Light path diagnostics Page Using the documentation Before you callGetting help and information from the World Wide Web Page Index Password Scsi RAID