Multi-Tech Systems MMV1600 Snga..H, $Dsuacl, $Dsubcl, $Dsuasp, $Dsubsp, $Muxacl, $Muxbcl, $Muxasp

Page 43

 

F14

Xoff/Xon Character Pacing

 

 

 

I0-2

Identification Commands

 

 

 

L,L0

List all Channel Parameters

 

 

 

L1-L32

List individual Channel Parameters

 

 

 

ML

Link Used Per Channel

 

 

 

P0

Parity None

 

 

 

P1

Parity Odd

 

 

 

P2

Parity Even

 

 

 

R

Response Time Priority

 

 

 

SB

Stop Bit Selection

 

 

 

SN

Local Source Node Number

 

 

 

 

Table 5-1. Command Summary (Cont.)

 

 

TYPE

COMMAND

DESCRIPTION

 

 

Channel

SNGA..H

Downline Load Source Number

 

 

Parameter

WL

Word Length

 

 

(Cont.)

&F

Load Factory Defaults

 

 

 

&SL

Select Local Parameters

 

 

 

&SR

Select Downline Parameters

 

 

 

#S

Channel Statistics

 

 

 

 

 

 

 

Composite

$DSUACL

Selects Clocking for Internal DSU on Link A

Link Speed

$DSUBCL

Selects Clocking for Internal DSU on Link B

 

 

and Clock

$DSUASP

Selects Speed of Internal DSU on Link A

 

 

 

$DSUBSP

Selects Speed of Internal DSU on Link B

 

 

Port A

$MUXACL

Selects Clocking when external DSU/

 

Modem for

 

 

 

 

 

$MUXBCL

Selects Clocking from external sync device

 

for Port B

Port A

$MUXASP

Speed of the Clocking if Supplied by the

 

Multiplexer

 

 

 

 

Port B

$MUXBSP

Speed of the Clocking if Supplied by the

 

Multiplexer

 

 

 

 

 

$MUXBSYNC

Selects Port B as Sync Data Channel

 

 

 

$MUXBCOMP

Selects Port B as Composite Link

 

 

 

 

 

 

 

Additional

#C

Clear Composite Statistics

 

 

Composite

$F

Load Factory Defaults for DSU and ISCC

 

 

Link

#FT

Flush Timer Value

 

 

 

$L

List Configuration of Port A and Port B

 

 

 

#L

List Composite Link Settings

 

 

 

#RB

Set Auto reporting Baud Rate

 

 

 

#RT

Set Auto Reporting Time Interval

 

 

 

#RXT

Programmable Retransmit Timer

 

 

 

#S

Composite Link Statistics

 

 

 

#SL

Status of Front Panel LEDs

 

 

 

 

 

 

 

Voice/Fax

VL

List the Voice/Fax Channel Parameters

 

 

Channel

V(1/2)Z

Reset Voice/Fax Channel

 

 

 

V(1/2)DC

Voice/Fax Destination Channel

 

 

 

V(1/2)DN

Voice/Fax Destination Node

 

 

 

V(1/2)ML

Link the Voice/Fax Channel will

 

 

Communicate Over

 

 

 

 

V(1/2)DR

Voice/Fax Channel Digitizing Rate

 

 

 

V(1/2)OL

Voice/Fax Channel Output Level Attentuation

 

 

 

V(1/2)IL

Voice/Fax Channel Input Level Gain

 

 

 

V(1/2)SS

Voice/Fax Silence Suppression

 

 

 

 

 

 

 

 

 

5-1. Command Summary (Cont.)

 

 

TYPE

COMMAND

DESCRIPTION

 

 

Additional

V(1/2)LI

Voice/Fax Channel Local Interface Type

 

 

Voice/Fax

V(1/2)RI

Voice/Fax Channel Remote Interface Type

 

 

Channel

V(1/2)WT

Voice/Fax Channel Wink Timer

 

 

 

 

 

 

 

Test

&T1-3

Memory Tests

 

 

 

&T4

Local Loop

 

 

Image 43
Contents MultiMux Page Record of Revisions RevisionDescription MultiMux #MMV1600C #MMV3200CTable of Contents Service, Warranty and Tech Support CommandsOperating Procedures TroubleshootingTables AboutThisManual Service, Warranty and Tech Support Description of Statistical Multiplexing Background1.1 Statistical Multiplexing Product Description CommunicationsMultiMux MMV1600/3200 Series Block Diagram Page Dynamic Load Balance System Features Voice/FaxNetworking Dual Composite LinksParameter Memory Channel SwitchingCommand Modem DiagnosticsResponse Time Control Dynamic BufferingSynchronous Data Channel AU7USA-20328-MD-E FCC Regulations for Telephone Line InterconnectionDOC Terminal Equipment AU7USA-18883-DE-N DSUInternal DSU Specifications Async Data ChannelsSystem Control Composite LinkDtmf Voice ChannelsElectrical/Physical CompatibilityModel Description Configuration DescriptionConfiguration Configuration 1 Remote Site Channel Parameters Configuration 1 Local Site Channel ParametersConfiguration 1 Composite Link Configuration Configuration 2 Composite Link Configuration Remote Site Configuration 3 Remote Site 1 Channel Parameters Configuration 3 Local Site Channel ParametersConfiguration 3 Remote Site 2 Channel Parameters Configuration 4 Local Site Voice/Fax Channel Parameters Configuration 4 FXO to FXSConfiguration 4 Remote Site Voice/Fax Channel Parameters Configuration 5 E&M Configuration 5 Remote Site Voice/Fax Channel Parameters Configuration 5 Local site Voice/Fax Channel ParametersConfiguration 6 FXS to FXS Configuration 6 Remote Site Voice/Fax Channel Parameters Configuration 6 Local Site Voice/Fax Channel ParametersRemote Site Configuration 7 Remote Site Voice/Fax Channel Parameters Configuration 7 Local Site Voice/Fax Channel ParametersConfiguration 8 LAN to LAN Page External Modem/DSU with RS232C Interface InstallationProcedureCabling Procedure StepProcedureAsync Channel Step ProcedureV.35 Interface Sync Data Channel Port B onlyComposite Link Cabling Supervisory Console Configuration ProcedureCommand Modem Step Procedure Voice/Fax Channels Step Procedure Async ChannelsPage Type Command Description Command SummaryATC1B4800P1F1E0 $DSUASP SNGA..H$DSUACL $DSUBCLGeneral Commands CommandDescription#MA Help H command menu is as follows General HelpStore New ParametersH7 menu is as follows H4 menu is as followsH5 menu is as follows H6 menu is as followsChannel Parameter Commands DTR ENQ/ACKMLA/B/D SB2 SB1$ Muxacli Composite Link Speed and Clocking Commands$DSUCL $DSUSP$MUXB Additional Composite Link Commands#RBxxxxx Retransmit TimerList Composite ReportVoice/Fax Channel Commands Command Level ATV1/2LIFXO WireSilence Suppression Local InterfaceATV1/2RIFXSG Test CommandsATV1/2LIFXSL ATV1/2RIFXOT11 Command Modem CommandsT12 Configuration of Port B Composite Link MultiMuxOperatingProceduresMultiMux Operating Procedures Configuration of Port a Composite LinkConfiguration of Port B Sync Data Voice/Fax Operating Procedures Voice/Fax Operating ProceduresCommand Modem Operating Procedures Command Modem Operating ProceduresCommand Modem Access on Command modem operation and put Introduction ImportanceofCompositeStatisticsData Troubleshooting Guide TroubleshootingGuideTestCables RD LED on RD OFF Voice/fax channel Voice/Fax Troubleshooting GuideCannot communicate Channel Device Testing Procedure ChannelDeviceTestingLocal Loop Test #4 DSU and Communications Line Testing Procedure DSUandCommunicationsLineTestingRemote Digital Loop Test #5 MultiMux Functional Testing Procedures MultiMuxFunctionalTestingProceduresWatch DOG Test Passed Voice/Fax Channel Testing Procedure Voice/FaxChannelTestingVOICE/FAX Loopback Test #12 Sync Data Channel Testing Procedure SyncDataChannelTestingService, Warranty and Tech Support Repair Procedures for International Distributors AppendixA Ascii Character Code/Hex/Decimal Conversion ChartAppendix B Signal Information Negative PositiveAppendix C Cabling DiagramsDCE to DTE cabling Command Port CablesComposite Link Cabling RJ48 Cabling for Internal DSU I-V Voice/Fax Channel Cable RJ45 Spade Lug Wire Color FunctionVoice/Fax Channel Connectors Description FXO Description FXS DescriptionLast Command Name DefaultAnswer a RepeatATQ1 ATH1ATH0 ATOWrite ATD5551212RRegister Read orStore Active Configuration displaysView Active User ProfilesATX1 ATX0ATX2 After Dial Command ExecutionMode While Returning toIndicator Description Table E-1. LED IndicatorsAppendix E Back Panel LED Indicators DescriptionFCR Command Port TERMINAL/PC Connector ON/OFF SwitchPower Connector BPS Modem DIAL-UP Line ConnectorVOICE/FAX Channel 1 FXS Connector VOICE/FAX Channel 2 FXS ConnectorVOICE/FAX Channel 2 FXO Connector VOICE/FAX Channel 1 E&M ConnectorRS232C/V.35 Shunt Channel Board Number of Channels SwitchChannel # Flow Control Background Appendix FOff Printer pacing and Flow Control Glossary of Terms Page Format Page Parameter Page Page Symbols DSU DOCFXO FXS External Composite LinkLads Link Protocol List Channel Parameters CommandLoad DSU Factory Defaults Command MultiMux Functional Testing ProcedureRJ48S PDNPstn RENTransmit XMT Indicator Stop Bit Command SB1-SB2Stdm Voice/Fax Channels Voice/Fax Channel Testing ProcedureVoice/Fax Input Level Gain Command Word Length Select Command WL5-8