7.6
DSUandCommunicationsLineTesting
After determining that the
Table 7-4. DSU and Communications Line Testing Procedure
Step Procedure
1Set the source and destination nodes on the local MultiMux to the same node number.
2Place the remote MultiMux unit in Test Mode 5 (Digital Loopback test) by entering the following command.
AT&5 (hit Return)
The supervisory console will display the following message:
REMOTE DIGITAL LOOP - TEST #5
3Enter data on the keyboard of each channel device on the local MultiMux and, if the network is operating correctly, the data will be correctly displayed on the local channel device monitor. If the channel device is equipped with an active local echo feature, double characters will be displayed.
4When you have verified that the communications link is operating correctly, enter the following to end the test:
ATZ (hit Return)
or
AT&T0 (hit Return)