Store New | The | Store | New | Parameters | command | causes | the | MultiMux | to | ||||
Parameters | store | new | parameters. | Prior | to | executing | the | &W | command, | ||||
| changes | to | MultiMux | parameters | are | temporary | and | do | not | ||||
&W | affect the unit’s operation until you execute the &W command. | The &W command | |||||||||||
stores the parameters in nonvolatile memory | and will takes affect immediately. |
|
|
|
| ||||||||
Help | The Help commands are designed to give you short explanations |
|
|
|
| ||||||||
| on | how | to | use MultiMux commands. They will | be | useful | if | your | |||||
H | manual is not handy, although the explanations are quite short |
|
|
|
| ||||||||
| in | comparison | to | those | in the | manual. | When a | Help | command | ||||
| is executed in conjunction with some other command, the |
|
|
|
|
| |||||||
| resulting display will explain options and information for that |
| command. The General | ||||||||||
Help command provides information |
| on the other MultiMux | Help commands. |
|
|
|
| ||||||
|
|
| The H command menu is as follows: |
|
|
|
|
| |||||
|
|
|
|
| General Help |
|
|
|
|
|
|
| |
1. Each command line must begin with the prefix AT. |
|
|
|
|
|
|
| ||||||
2. | Each command line may contain any number of commands up |
| to 40 characters total. |
| |||||||||
3. Most command letters must be followed by a value. |
|
|
|
|
|
|
| ||||||
4. For help on specific commands, enter "ATH" followed by the | command letters. |
|
|
|
5.For additional help menus, enter "ATH" followed by numbers
A.Type ATH or ATH0 for General Help.
B.Type ATH1 for channel parameter commands.
C.Type ATH2 to view the DIP switch configuration.
D.Type ATH3 for composite link speed and clocking commands.
E.Type ATH4 for additional composite link commands.
F.Type ATH5 for miscellaneous commands.
G.Type ATH6 for voice/fax channel commands.
H.Type ATH7 for additional voice/fax channel commands.
The H1 menu is as follows:
CHANNEL PARAMETER COMMANDS
B | - | BAUD RATE SELECTION | P | - | PARITY SELECTION |
|
C | - | CHANNEL SELECTION | R | - | RESPONSE TIME PRIORITY |
|
DC | - | DEST. CHANNEL SELECTION | SB | - | STOP BIT SELECTION |
|
DN | - | DEST. NODE SELECTION | SN | - | LOCAL SOURCE NODE NUMBER |
|
E | - | LOCAL ECHO | SNGA..H - | DOWNLINE LOAD SOURCE NODE NUMBER |
| |
F | - | FLOW CONTROL | #S | - | CHANNEL STATISTICS |
|
&F | - | READ IN FACTORY DEFAULTS &SL - | SELECT LOCAL PARAMETERS |
| ||
L | - | LIST PARAMETERS | &SR - | SELECT DOWNLINE LOAD PARAMETERS |
| |
ML | - | LINK USED PER CHANNEL | WL | - | WORD LENGTH SELECTION |
|
THE FOLLOWING EXAMPLE WILL SELECT CHANNEL 1 AND SET ITS BAUD RATE | TO 2400 AND |
THE WORD LENGTH TO 8 BITS:
ATC1B2400WL8 <ENTER>
FOR HELP ON A SPECIFIC COMMAND, ENTER “ATH” FOLLOWED BY A COMMAND LETTER
The H2 menu is as follows:
MULTIMUX EIGHT POSITION
| SWITCH 1 SWITCH 2 SWITCH 3 SWITCH 4 SWITCH 5 SWITCH 6 SWITCH 7 SWITCH 8 | |||||||
| INITIATE | DSU | DSU | 8/16 | 24/32 | REMOTE |
|
|
| DWN | TYPE | TYPE | CHANNEL CHANNEL ACCESS |
|
| ||
| LINE | LINK A | LINK B |
|
|
|
|
|
| LOAD |
|
|
|
|
|
|
|
UP = | ON | INTERNAL | INTERNAL | 16/32 | 24/32CHAN | ENABLED |
|
|
DN = | OFF | EXTERNAL | EXTERNAL | 8/24 | 8/16CHAN | DISABLED |
|
|
CURRENT SETTINGS: |
|
|
|
|
|
| ||
| DN | DN | DN | DN | DN | DN | DN | DN |
The H3 menu is as follows:
COMPOSITE LINK CLOCKING AND SPEED COMMANDS
INTERNAL DSU