Voice/Fax Channel Commands

The Voice/Fax Channel commands control the traffic of the voice and fax communication over the composite link network. The

Voice/Fax Channel commands are described in detail below:

 

 

 

List The Voice/Fax

List The Voice/Fax Channel Parameters command causes the

 

Channel

MultiMux to display the parameters for the Voice/Fax channels

 

Parameters

on the system's supervisory console as shown in the following

example. The Voice/

Fax channel parameters display general

VL parameters for both channels and the local and remote channel

 

interfaces. To display the parameters for the Voice/Fax channels,

you would enter ATVL

and hit your Return key.

 

 

 

 

 

LOCAL VOICE/FAX PARAMETERS CHANNEL1 LOCAL VOICE/FAX PARAMTERS CHANNEL 2

 

PARAMETER

 

STATUS

PARAMETER

 

STATUS

 

DESTINATION CHANNEL

01

DESTINATION CHANNEL

02

 

DESTINATION NODE

 

01

DESTINATION NODE

01

 

LINK A/B/D

 

A

LINK A/B/D

 

A

 

DIGITIZING RATE

 

16000

DIGITIZING RATE

 

16000

 

OUTPUT LEVEL ATTEN.

12

OUTPUT LEVEL ATTEN.

12

 

INPUT LEVEL GAIN

 

03

INPUT LEVEL GAIN

03

 

SILENCE SUPPRESSION

02

SILENCE SUPPRESSION

02

 

LOCAL INTERFACE TYPE

FXS

LOCAL INTERFACE TYPE

FXS

 

GROUND/LOOP START (FXS)

LOOP

GROUND/LOOP START (FXS)

LOOP

 

2 OR 4 WIRE (E&M)

 

2 WIRE

2 OR 4 WIRE (E&M)

2 WIRE

 

DIALTONE/WINK (E&M)

N/A

DIALTONE/WINK (E&M)

N/A

 

WINK TIMER

 

N/A

WINK TIMER

 

N/A

 

REMOTE INTERFACE TYPE

FXS

REMOTE INTERFACE TYPE

FXS

 

GROUND/LOOP START (FXS)

LOOP

GROUND/LOOP START (FXS)

LOOP

 

2 OR 4 WIRE (E&M)

 

2 WIRE

2 OR 4 WIRE (E&M)

2 WIRE

 

DIALTONE/WINK (E&M)

N/A

DIALTONE/WINK (E&M)

N/A

 

Reset

The Reset

Voice/Fax Channel command sets the operating

 

Voice/Fax

parameters for the voice/fax channel to the most recently

 

Channel

stored values and resets that channel.

 

 

 

V(1/2)Z

 

 

 

 

 

 

Voice/Fax

The Voice/Fax Destination Channel command selects which

 

Destination

voice/fax channel (1 or 2) on the destination MultiMux will receive

 

Channel

the voice/fax information. Local voice channel 1 (V1) can select

 

V(1/2)DC

destination channel 1 DC1 or destination channel 2 DC2 to

receive the information.

Similarily, V2 can select DC1 or DC2.

 

 

 

 

Voice/Fax

The voice/Fax Destination Node command (V(1/2)DN(0-31))

 

Destination Node

selects the destination MultiMux (0-31) for which voice/fax data

will be sent. The voice/

fax channels 1 or 2 can select destination

V(1/2)DN

nodes from 0 to 31. Voice/fax channel 1 can select a

destination

node of 25 using V1DN25 command.

 

 

Link the Voice/Fax

The Link the voice/Fax Channel will Communicate Over command

 

Channel will

(V(1/2)ML(A/B/D)) selects the composite link (A/B/D) in which

 

Communicate Over

the voice/fax data will be sent. Local voice/fax channel 1 can

send voice/fax data

over composite link A by executing V1MLA

V(1/2)ML

command. The V2MLD command enables voice/fax channel

Image 54
Contents MultiMux Page MultiMux #MMV1600C #MMV3200C Record of Revisions RevisionDescriptionTable of Contents Troubleshooting CommandsOperating Procedures Service, Warranty and Tech SupportTables AboutThisManual Service, Warranty and Tech Support Background Description of Statistical Multiplexing1.1 Statistical Multiplexing Communications Product DescriptionMultiMux MMV1600/3200 Series Block Diagram Page Dual Composite Links System Features Voice/FaxNetworking Dynamic Load BalanceDiagnostics Channel SwitchingCommand Modem Parameter MemoryDynamic Buffering Response Time ControlSynchronous Data Channel AU7USA-18883-DE-N DSU FCC Regulations for Telephone Line InterconnectionDOC Terminal Equipment AU7USA-20328-MD-EComposite Link Specifications Async Data ChannelsSystem Control Internal DSUCompatibility Voice ChannelsElectrical/Physical DtmfConfiguration Description Model DescriptionConfiguration Configuration 1 Local Site Channel Parameters Configuration 1 Remote Site Channel ParametersConfiguration 1 Composite Link Configuration Configuration 2 Composite Link Configuration Remote Site Configuration 3 Local Site Channel Parameters Configuration 3 Remote Site 1 Channel ParametersConfiguration 3 Remote Site 2 Channel Parameters Configuration 4 FXO to FXS Configuration 4 Local Site Voice/Fax Channel ParametersConfiguration 4 Remote Site Voice/Fax Channel Parameters Configuration 5 E&M Configuration 5 Local site Voice/Fax Channel Parameters Configuration 5 Remote Site Voice/Fax Channel ParametersConfiguration 6 FXS to FXS Configuration 6 Local Site Voice/Fax Channel Parameters Configuration 6 Remote Site Voice/Fax Channel ParametersRemote Site Configuration 7 Local Site Voice/Fax Channel Parameters Configuration 7 Remote Site Voice/Fax Channel ParametersConfiguration 8 LAN to LAN Page StepProcedure InstallationProcedureCabling Procedure External Modem/DSU with RS232C InterfaceSync Data Channel Port B only Step ProcedureV.35 Interface Async ChannelComposite Link Cabling Configuration Procedure Supervisory ConsoleCommand Modem Step Procedure Async Channels Step Procedure Voice/Fax ChannelsPage Command Summary Type Command DescriptionATC1B4800P1F1E0 $DSUBCL SNGA..H$DSUACL $DSUASPCommandDescription General Commands#MA Parameters H command menu is as follows General HelpStore New HelpH6 menu is as follows H4 menu is as followsH5 menu is as follows H7 menu is as followsChannel Parameter Commands ENQ/ACK DTRMLA/B/D SB1 SB2$DSUSP Composite Link Speed and Clocking Commands$DSUCL $ MuxacliAdditional Composite Link Commands $MUXBReport Retransmit TimerList Composite #RBxxxxxVoice/Fax Channel Commands Command Level Local Interface WireSilence Suppression ATV1/2LIFXOATV1/2RIFXO Test CommandsATV1/2LIFXSL ATV1/2RIFXSGCommand Modem Commands T11T12 Configuration of Port a Composite Link MultiMuxOperatingProceduresMultiMux Operating Procedures Configuration of Port B Composite LinkConfiguration of Port B Sync Data Voice/Fax Operating Procedures Voice/Fax Operating ProceduresCommand Modem Operating Procedures Command Modem Operating ProceduresCommand Modem Access on Command modem operation and put ImportanceofCompositeStatistics IntroductionTroubleshootingGuide Data Troubleshooting GuideTestCables RD LED on RD OFF Voice/Fax Troubleshooting Guide Voice/fax channelCannot communicate ChannelDeviceTesting Channel Device Testing ProcedureLocal Loop Test #4 DSUandCommunicationsLineTesting DSU and Communications Line Testing ProcedureRemote Digital Loop Test #5 MultiMuxFunctionalTestingProcedures MultiMux Functional Testing ProceduresWatch DOG Test Passed Voice/FaxChannelTesting Voice/Fax Channel Testing ProcedureVOICE/FAX Loopback Test #12 SyncDataChannelTesting Sync Data Channel Testing ProcedureService, Warranty and Tech Support Repair Procedures for International Distributors Ascii Character Code/Hex/Decimal Conversion Chart AppendixASignal Information Negative Positive Appendix BCabling Diagrams Appendix CCommand Port Cables DCE to DTE cablingComposite Link Cabling RJ48 Cabling for Internal DSU Description FXO Description FXS Description RJ45 Spade Lug Wire Color FunctionVoice/Fax Channel Connectors I-V Voice/Fax Channel CableRepeat Command Name DefaultAnswer a LastATO ATH1ATH0 ATQ1Read or ATD5551212RRegister WriteUser Profiles Configuration displaysView Active Store ActiveATX0 ATX1ATX2 Returning to Command ExecutionMode While After DialTable E-1. LED Indicators Indicator DescriptionAppendix E LED Indicators Description Back PanelFCR BPS Modem DIAL-UP Line Connector ON/OFF SwitchPower Connector Command Port TERMINAL/PC ConnectorVOICE/FAX Channel 1 E&M Connector VOICE/FAX Channel 2 FXS ConnectorVOICE/FAX Channel 2 FXO Connector VOICE/FAX Channel 1 FXS ConnectorChannel Board Number of Channels Switch RS232C/V.35 ShuntChannel # Appendix F Flow Control BackgroundOff Printer pacing and Flow Control Glossary of Terms Page Format Page Parameter Page Page Symbols DOC DSUExternal Composite Link FXO FXSLads MultiMux Functional Testing Procedure List Channel Parameters CommandLoad DSU Factory Defaults Command Link ProtocolREN PDNPstn RJ48SStop Bit Command SB1-SB2 Transmit XMT IndicatorStdm Word Length Select Command WL5-8 Voice/Fax Channel Testing ProcedureVoice/Fax Input Level Gain Command Voice/Fax Channels