not communicating |
| not installed on Supervisory |
| supervisory console, refer to comm | with mux command | ||
Console. |
| software user’s manual forinstallation. |
|
|
| ||
port | 2. | Bad cable or cable | 1. | Check RS232 cable connections |
|
| |
|
|
| |||||
connection | between supervisory |
|
| console and COMMAND PORT on |
| ||
|
| MultiMux for loose connection or |
| bent pins, refer to Supervisory | |||
|
|
|
| Console Installation procedures in |
|
| |
Chapter 4 |
|
|
|
|
|
|
|
|
|
| 2. | Check RS232 cable connections |
|
| |
between supervisory console and |
|
| COMMAND PORT on MultiMux for |
| |||
|
| correct cable wiring, refer to Cable |
| Diagrams in Appendix | |||
C. |
|
|
|
|
|
|
|
Supervisory Console | 1. Incorrect command | 1. | Verify command modem baud rate is | not communicating | |||
modem baud rate |
| set to 2400 bps, refer to Comm | with command mode |
| Software | ||
User’s Manual. |
|
|
|
|
|
|
|
|
|
| 2. | Call Tech Support for assistance, |
|
| |
refer to Chapter 8 |
|
|
|
|
|
|
|
Garbage on | 1. Incorrect session | 1. | Verify session parameters (data bits | Supervisory | parameters | ||
| of 8, parity none, 1 stop bit), refer to | Console Screen |
| comm | |||
software user’s manual for |
|
|
| parameter settings. |
|
| |
|
|
| 2. | Call Tech Support for assistance, |
|
| |
refer to Chapter 8 |
|
|
|
|
|
|
|
Composite Link down | 1. Composite Link cabling | 1. | If internal DSU is installed, check |
|
| ||
with CTS, XMT, and | connection. |
| Composite Link cabling for loose | RD LEDs ON |
| ||
|
|
|
|
|
| ||
|
|
| 2. | If external DSU or modem is |
|
| |
installed, check RS232C/V.35 cable |
|
| between devices for loose |
| |||
|
| connection or bent pin. |
|
|
|
|
|
| 2. Not receiving data from | 1. | Verify that both muxes are powered |
| remote mux | ||
| ON. |
|
|
|
|
| |
|
|
| 2. | Verify that both muxes are |
|
| |
connected to communications line. |
|
|
|
|
| ||
|
| Table |
| ||||
Condition |
| Possible Cause |
|
| Corrective Action |
|
|
Composite link down | 2. Not receiving data from | 3. | If external modem are used, verify | with CTS, XMT and | |||
remote mux (Continued) | that they are powered ON and |
|
|
|
| ||
RD LEDs ON |
|
|
| connected to the communication |
|
| |
(Continued) |
|
|
| line and Mux composite link. |
|
| |
|
|
| 4. | Call Tech Support for assistance, |
|
| |
|
|
|
| refer to Chapter 8. |
|
| |
communication line. | 3. Faulty communication line | 1. Call phone company and verify |
|
| |||
|
|
|
|
|
|
| |
|
|
| 2. | Call Tech Support for assistance, |
|
| |
refer to Chapter 8. |
|
|
|
|
|
|
|
Composite Link down | 1. Both Muxes set up for | 1. | Remove front cover of both muxes |
|
| ||
with CD, CTS, XMT and |
| down line loading |
| and verify if |
|
| |
RCV LEDs ON and |
|
|
| UP (ON) position. |
|
| |
RD LED ON |
|
| 2. | Place |
|
| |
|
|
|
|
| |||
muxes in the DOWN (OFF) position. |
|
|
|
|
| ||
|
|
| 3. | Call Tech Support for assistance, |
|
| |
refer to Chapter 8. |
|
|
|
|
|
|
|
| 2. Internal DSU speeds | 1. | Verify internal DSU speeds with $L | on local and remote | |||
| command, refer to Chapter 5. |
|
|
|
|
| |
|
| muxes do not match. |
|
|
|
|
|
Composite link down | 1. External modem settings | 1. | Verify that external modem is set for |
|
| ||
with CD, CTS and |
| remote mux |
| sync, full duplex and internal clocking. |
|
|