Graco 312359J important safety instructions Contents

Page 2

Contents

Related Manuals . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

Usage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

Isocyanate Hazard . . . . . . . . . . . . . . . . . . . . . . . 9

Material Self-Ignition . . . . . . . . . . . . . . . . . . . . . . 9

Moisture Sensitivity of Isocyanates . . . . . . . . . . . 9

Components A and B . . . . . . . . . . . . . . . . . . . . 10

Changing Materials . . . . . . . . . . . . . . . . . . . . . . 10

Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

Grounding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

Proper Lifting of Sprayer . . . . . . . . . . . . . . . . . . . 11

Initial System Setup . . . . . . . . . . . . . . . . . . . . . . . 12

Component Identification . . . . . . . . . . . . . . . . . . . 13

Typical Setup: 20 Gallon Hoppers with Recirculation (Front View) . . . . . . . . . . . . . . . . . . . . . . . . 13 Typical Setup: 20 Gallon Hoppers with Recirculation (Back View) . . . . . . . . . . . . . . . . . . . . . . . . . 14 Fluid Control Assembly . . . . . . . . . . . . . . . . . . . 15 Junction Box/Heater Controls . . . . . . . . . . . . . . 16 Air Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 User Interface . . . . . . . . . . . . . . . . . . . . . . . . . . 17

Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

Connect Power Cord . . . . . . . . . . . . . . . . . . . . . 19 Configure to Supply Power . . . . . . . . . . . . . . . . 20 Wire Sprayers with Explosion-Proof Heaters . . 21 Connect Air Supply . . . . . . . . . . . . . . . . . . . . . . 21 Connect Fluid Hose Assembly . . . . . . . . . . . . . 22 Adjust Packing Nuts . . . . . . . . . . . . . . . . . . . . . 22

Basic Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . 23

Power On (Alternator Power Supplied Systems) 23

Power On (Wall Power Supplied Systems) . . . . 23

Adjust Ratio and Setup . . . . . . . . . . . . . . . . . . . 23

Final Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23

View Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . 23

Set System Settings (Optional) . . . . . . . . . . . . . 24

Set Maintenance Parameters (Optional) . . . . . . 25

Set Sprayer Limits (Optional) . . . . . . . . . . . . . . 26

Prime . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27

Prime A and B Fluids . . . . . . . . . . . . . . . . . . . . 27 Prime Solvent Flush Pump . . . . . . . . . . . . . . . . 29

Recirculate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30

Without Heat . . . . . . . . . . . . . . . . . . . . . . . . . . . 30

With Heat . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31

Heat Fluid . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31

2

Spray . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32

Adjust B Machine Outlet Restriction . . . . . . . . . . 33

Pressure Relief Procedure . . . . . . . . . . . . . . . . . . 34

Flush Mixed Material . . . . . . . . . . . . . . . . . . . . . . . 36

Park Fluid Pump Rods . . . . . . . . . . . . . . . . . . . . . . 38

Shutdown Entire System . . . . . . . . . . . . . . . . . . . . 39

System Verification . . . . . . . . . . . . . . . . . . . . . . . . 40

Mix and Integration Tests . . . . . . . . . . . . . . . . . . 40

Pump and Metering Test . . . . . . . . . . . . . . . . . . 40

Batch Ratio Dispense Test . . . . . . . . . . . . . . . . 43

Down Stream Valve Leak Test . . . . . . . . . . . . . . 44

XM Setup and Troubleshooting Guide . . . . . . . . 45

Empty and Flush Entire System

 

(new sprayer or end of job)

46

Download Data from USB . . . . . . . . . . . . . . . . . . . 48

USB Logs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48

Download Setup . . . . . . . . . . . . . . . . . . . . . . . . 48

Download Procedure . . . . . . . . . . . . . . . . . . . . . 48

Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50

Filters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50

Seals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50

Cleaning Procedure . . . . . . . . . . . . . . . . . . . . . . 50

Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51

View Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51

Diagnose Alarms . . . . . . . . . . . . . . . . . . . . . . . . 51

Clear Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . 51

Alarm Codes and Troubleshooting . . . . . . . . . . 52

LED Diagnostic Information . . . . . . . . . . . . . . . . 58

Accessories and Kits . . . . . . . . . . . . . . . . . . . . . . . 59 Appendix A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61

User Interface Display . . . . . . . . . . . . . . . . . . . . 61

Setup Mode Screens . . . . . . . . . . . . . . . . . . . . . 62

Operator Command Functions Screens . . . . . . 69

Auto Display Screens . . . . . . . . . . . . . . . . . . . . 75

Appendix B . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77

Metering Diagrams . . . . . . . . . . . . . . . . . . . . . . 77

Appendix C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79

Power Cord Guidelines . . . . . . . . . . . . . . . . . . . 79

Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80

System Dimensions without Hoppers . . . . . . . . 80 System Dimensions with Hoppers . . . . . . . . . . . 81 System Dimensions with Hoppers . . . . . . . . . . . 82

Pump Performance Charts . . . . . . . . . . . . . . . . . . 83

Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84

Graco Standard Warranty . . . . . . . . . . . . . . . . . . . 86

Graco Information . . . . . . . . . . . . . . . . . . . . . . . . . 86

312359J

Image 2
Contents XM Plural-Component Sprayers312359J Contents Related Manuals Manual DescriptionFire and Explosion Hazard Intrinsic Safety Equipment Misuse Hazard Models Location Category KeyCode ApprovalsXM a XM B XM D XM C XM E FiltersIsocyanate Hazard OverviewUsage Material Self-Ignition Moisture Sensitivity IsocyanatesKeep Components a and B Separate Components a and BChanging Materials Location Lift Using a ForkliftLift Using a Hoist Proper Lifting of SprayerInitial System Setup Component Identification Typical Setup 20 Gallon Hoppers with Recirculation Back View Fluid Control Assembly Fluid Control AssemblyIG Junction Box/Heater Controls Junction Box/Heater ControlsAir Controls IG Air ControlsUser Interface LEDsUser Interface Display Interface Display, Main Display Screen ComponentsPower Cord Requirements SetupConnect Power Cord Terminal Blocks Configure to Supply PowerNon-hazardous location sprayers only Hazardous location sprayers only Wire Sprayers with Explosion-Proof HeatersConnect Air Supply Connect Fluid Hose Assembly Adjust Packing NutsBasic Operation Set USB Parameters Set System Settings OptionalSet User Interface Parameters Set Maintenance Setpoints Set Maintenance Parameters OptionalSet Maintenance Schedule Set Pressure Limits Set Temperature LimitsSet Sprayer Limits Optional Gallon Hopper Shown PrimePrime a and B Fluids Prime Prime Solvent Flush Pump Recirculate Without HeatWith Heat Heat FluidSpray Adjust B Machine Outlet Restriction Mix Manifold Restriction StemRelieve Pump Fluid Pressure and Flush Mix Hose Pressure Relief ProcedureRelieve a and B Fluid Pressure To flush mixed material out of line with clean solvent Use Solvent Pump Flush Mixed MaterialFlush Mix Manifold Follow Pressure Relief Procedure, Relieve pressure. See Pressure Relief Procedure, Park Fluid Pump RodsShutdown Entire System Follow Park Fluid Pump Rods onPump and Metering Test System VerificationMix and Integration Tests System Verification Confirm Pump Test Batch Ratio Dispense Test Down Stream Valve Leak Test Confirm Batch Dispense TestXM Setup and Troubleshooting Guide Procedure GuidelinesFollow Park Fluid Pump Rods, Download Data from USB Download SetupDownload Procedure USB LogsDownload Data from USB Filters MaintenanceCleaning Procedure SealsClear Alarms AlarmsDiagnose Alarms Icon FunctionAlarm Codes and Troubleshooting Alarm Code Alarm Problem When Active Cause SolutionAdjust B Machine Outlet Pump Test Daily Check Recommended Optional User-Settable Maintenance Warnings Optional User-Settable Spray Limits Possible Alarms by Mode Mode Control Logic AlarmsModule Status LED Signal Diagnosis Solution LED Diagnostic InformationAlarm Code Key What Alert WhereAccessories and Kits Caster Kit Electric Heated Hose Power Supply KitDesiccant Dryer Kit Hose Rack KitAppendix a Setup Functions key onCommand Functions key OFF or removed User Interface DisplaySetup Mode Screens Home Home Setup ScreensIcon Function System Setup Screens Set Potlife/Hose LengthSystem Number and USB Settings Pump ConfigurationEnable Setup Screens Fast Dosing Function Advisory B3A Alarm B4AMaintenance Setup Screens Maintenance SetupProcess Temperature Limits for spray mode User Limits Setup ScreensProcess Pressure Limits for spray mode Test Screens Operator Command Functions ScreensAlarm Control Screens Fluid Control ScreensPower On/Enter Mode Run Fluid Control ScreensRatio Mode Confirm Pump TestConfirm Batch Dispense Test Batch Dispense TestDown Stream Valve Leak Test Alarm Reset Maintenance Counter Maintenance 1 ScreenMaintenance 2 Screen Totalizers and Job NumberUSB Screen Auto Display ScreensPotlife Screen Recommended USB Flash DrivesExample Spray Log Appendix B Metering DiagramsMetering Diagram without Remote Mix Manifold XM Metering Diagram with Remote Mix Manifold Metering Diagram with Remote Mix ManifoldAppendix C Power Cord GuidelinesPower Cord Guidelines Dimensions System Dimensions without HoppersTwo 20-Gallon Hoppers Rear Mounted System Dimensions with HoppersTwo 20-Gallon Hoppers Side Mounted One 20-Gallon Hopper and One 7-Gallon Hopper Two 7-Gallon HoppersCalculate Pump Air Consumption Pump Performance ChartsCalculate Fluid Outlet Pressure XM50 Fluid Performance and Air ConsumptionTechnical Data Performance Charts ,Technical Data 312359J Graco Standard Warranty Graco Information

312359J specifications

The Graco 312359J is a versatile paint sprayer designed for both DIY enthusiasts and professionals alike. Known for its powerful performance and user-friendly features, this sprayer is ideal for various painting tasks, from small interior projects to larger exterior applications.

One of the standout features of the Graco 312359J is its robust piston pump system, which can handle thicker materials without compromising on quality. This allows users to spray a wide range of coatings, including stains, sealers, and even heavy-duty paints. The sprayer is engineered to deliver consistent pressure, ensuring an even and professional finish on every job.

Another significant characteristic of the Graco 312359J is its ability to produce a fine mist, which helps to reduce overspray and material waste. This is particularly beneficial for intricate projects where precision is critical. Additionally, the adjustable spray pattern can be easily configured to suit various tasks, allowing users to switch from broad coverage to detailed work with minimal effort.

The convenience of portability is another important aspect of the Graco 312359J. It features a lightweight design, making it easy to maneuver around different work areas. The integrated carrying handle further enhances mobility, allowing users to transport the sprayer without hassle.

In terms of technology, the Graco 312359J incorporates an easy-to-use control system, ensuring that even beginners can achieve professional-quality results. The user-friendly design simplifies setup and maintenance, while the quick-connect nozzle system allows for easy changes between different spray tips.

Moreover, the sprayer is equipped with a durable and easy-to-clean design. Users can quickly flush out the system after use, saving time and maintaining the equipment's longevity.

Ultimately, the Graco 312359J stands out for its combination of power, portability, and advanced features, making it an excellent choice for anyone looking to achieve a flawless finish. Its blend of practicality and efficiency caters to a wide range of applications, helping both novice and experienced users achieve outstanding results with ease. Whether tackling a home renovation or a professional job, this paint sprayer is designed to meet various painting needs effectively.