Graco 312359J important safety instructions Intrinsic Safety

Page 5

Warnings

WARNING

INTRINSIC SAFETY

Intrinsically safe equipment that is installed improperly or connected to non-intrinsically safe equipment will create a hazardous condition and can cause fire, explosion, or electric shock. Follow local regula- tions and the following safety requirements.

Only models with model number XM_D_ _ or XM_E_ _, and packaged models with part numbers ending in 00-13, 17-23, 27-29, 31, utilizing the air-driven alternator are approved for installation in a Hazardous (explosive atmosphere) Location - see Approvals:, page 8. Only the models stated above meet all local safety fire codes including NFPA 33, NEC 500 and 516, and OSHA 1910.107. To help prevent fire and explosion:

Do not install equipment approved only for a non-hazardous location in a hazardous location. See model ID label for intrinsic safety rating of your model.

Do not substitute system components as this may impair intrinsic safety.

Equipment that comes in contact with the intrinsically safe terminals must be rated for Intrinsic Safety. This includes DC voltage meters, ohmmeters, cables, and connections. Remove the unit from the hazardous area when troubleshooting.

Do not connect, download, or remove USB device unless unit is removed from the hazardous (explo- sive atmosphere) location.

If explosion-proof heaters are used, ensure wiring, wiring connections, switches, and electrical distri- bution panel all meet flame-proof (explosion-proof) requirements.

SKIN INJECTION HAZARD

High-pressure fluid from gun, hose leaks, or ruptured components will pierce skin. This may look like just a cut, but it is a serious injury that can result in amputation. Get immediate surgical treatment.

Do not point gun at anyone or at any part of the body.

Do not put your hand over the spray tip.

Do not stop or deflect leaks with your hand, body, glove, or rag.

Do not spray without tip guard and trigger guard installed.

Engage trigger lock when not spraying.

Follow Pressure Relief Procedure in this manual, when you stop spraying and before cleaning, checking, or servicing equipment.

PRESSURIZED EQUIPMENT HAZARD

Fluid from the gun/dispense valve, leaks, or ruptured components can splash in the eyes or on skin and cause serious injury.

Follow Pressure Relief Procedure in this manual, when you stop spraying and before cleaning, checking, or servicing equipment.

Tighten all fluid connections before operating the equipment.

Check hoses, tubes, and couplings daily. Replace worn or damaged parts immediately.

MOVING PARTS HAZARD

Moving parts can pinch or amputate fingers and other body parts.

Keep clear of moving parts.

Do not operate equipment with protective guards or covers removed.

Pressurized equipment can start without warning. Before checking, moving, or servicing equipment, follow the Pressure Relief Procedure in this manual. Disconnect power or air supply.

312359J

5

Image 5
Contents XM Plural-Component Sprayers312359J Contents Manual Description Related ManualsFire and Explosion Hazard Intrinsic Safety Equipment Misuse Hazard Location Category Key ModelsXM a XM B XM D XM C XM E ApprovalsCode FiltersUsage Material Self-Ignition OverviewIsocyanate Hazard Moisture Sensitivity IsocyanatesKeep Components a and B Separate Components a and BChanging Materials Lift Using a Hoist Lift Using a ForkliftLocation Proper Lifting of SprayerInitial System Setup Component Identification Typical Setup 20 Gallon Hoppers with Recirculation Back View Fluid Control Assembly Fluid Control AssemblyAir Controls Junction Box/Heater ControlsIG Junction Box/Heater Controls IG Air ControlsLEDs User InterfaceInterface Display, Main Display Screen Components User Interface DisplayPower Cord Requirements SetupConnect Power Cord Terminal Blocks Configure to Supply PowerNon-hazardous location sprayers only Hazardous location sprayers only Wire Sprayers with Explosion-Proof HeatersConnect Air Supply Adjust Packing Nuts Connect Fluid Hose AssemblyBasic Operation Set USB Parameters Set System Settings OptionalSet User Interface Parameters Set Maintenance Setpoints Set Maintenance Parameters OptionalSet Maintenance Schedule Set Pressure Limits Set Temperature LimitsSet Sprayer Limits Optional Gallon Hopper Shown PrimePrime a and B Fluids Prime Prime Solvent Flush Pump Without Heat RecirculateHeat Fluid With HeatSpray Mix Manifold Restriction Stem Adjust B Machine Outlet RestrictionRelieve Pump Fluid Pressure and Flush Mix Hose Pressure Relief ProcedureRelieve a and B Fluid Pressure To flush mixed material out of line with clean solvent Use Solvent Pump Flush Mixed MaterialFlush Mix Manifold Follow Pressure Relief Procedure, Park Fluid Pump Rods Relieve pressure. See Pressure Relief Procedure,Follow Park Fluid Pump Rods on Shutdown Entire SystemPump and Metering Test System VerificationMix and Integration Tests System Verification Confirm Pump Test Batch Ratio Dispense Test Confirm Batch Dispense Test Down Stream Valve Leak TestXM Setup and Troubleshooting Guide Guidelines ProcedureFollow Park Fluid Pump Rods, Download Procedure Download SetupDownload Data from USB USB LogsDownload Data from USB Cleaning Procedure MaintenanceFilters SealsDiagnose Alarms AlarmsClear Alarms Icon FunctionAlarm Code Alarm Problem When Active Cause Solution Alarm Codes and TroubleshootingAdjust B Machine Outlet Pump Test Daily Check Recommended Optional User-Settable Maintenance Warnings Optional User-Settable Spray Limits Mode Control Logic Alarms Possible Alarms by ModeAlarm Code Key LED Diagnostic InformationModule Status LED Signal Diagnosis Solution What Alert WhereAccessories and Kits Desiccant Dryer Kit Electric Heated Hose Power Supply KitCaster Kit Hose Rack KitCommand Functions key OFF or removed Setup Functions key onAppendix a User Interface DisplaySetup Mode Screens Home Home Setup ScreensIcon Function Set Potlife/Hose Length System Setup ScreensPump Configuration System Number and USB SettingsFast Dosing Function Advisory B3A Alarm B4A Enable Setup ScreensMaintenance Setup Maintenance Setup ScreensProcess Temperature Limits for spray mode User Limits Setup ScreensProcess Pressure Limits for spray mode Alarm Control Screens Operator Command Functions ScreensTest Screens Fluid Control ScreensRun Fluid Control Screens Power On/Enter ModeConfirm Pump Test Ratio ModeConfirm Batch Dispense Test Batch Dispense TestDown Stream Valve Leak Test Alarm Maintenance 2 Screen Maintenance 1 ScreenReset Maintenance Counter Totalizers and Job NumberPotlife Screen Auto Display ScreensUSB Screen Recommended USB Flash DrivesExample Spray Log Appendix B Metering DiagramsMetering Diagram without Remote Mix Manifold Metering Diagram with Remote Mix Manifold XM Metering Diagram with Remote Mix ManifoldAppendix C Power Cord GuidelinesPower Cord Guidelines System Dimensions without Hoppers DimensionsTwo 20-Gallon Hoppers Rear Mounted System Dimensions with HoppersTwo 20-Gallon Hoppers Side Mounted Two 7-Gallon Hoppers One 20-Gallon Hopper and One 7-Gallon HopperCalculate Fluid Outlet Pressure Pump Performance ChartsCalculate Pump Air Consumption XM50 Fluid Performance and Air ConsumptionPerformance Charts , Technical DataTechnical Data 312359J Graco Information Graco Standard Warranty

312359J specifications

The Graco 312359J is a versatile paint sprayer designed for both DIY enthusiasts and professionals alike. Known for its powerful performance and user-friendly features, this sprayer is ideal for various painting tasks, from small interior projects to larger exterior applications.

One of the standout features of the Graco 312359J is its robust piston pump system, which can handle thicker materials without compromising on quality. This allows users to spray a wide range of coatings, including stains, sealers, and even heavy-duty paints. The sprayer is engineered to deliver consistent pressure, ensuring an even and professional finish on every job.

Another significant characteristic of the Graco 312359J is its ability to produce a fine mist, which helps to reduce overspray and material waste. This is particularly beneficial for intricate projects where precision is critical. Additionally, the adjustable spray pattern can be easily configured to suit various tasks, allowing users to switch from broad coverage to detailed work with minimal effort.

The convenience of portability is another important aspect of the Graco 312359J. It features a lightweight design, making it easy to maneuver around different work areas. The integrated carrying handle further enhances mobility, allowing users to transport the sprayer without hassle.

In terms of technology, the Graco 312359J incorporates an easy-to-use control system, ensuring that even beginners can achieve professional-quality results. The user-friendly design simplifies setup and maintenance, while the quick-connect nozzle system allows for easy changes between different spray tips.

Moreover, the sprayer is equipped with a durable and easy-to-clean design. Users can quickly flush out the system after use, saving time and maintaining the equipment's longevity.

Ultimately, the Graco 312359J stands out for its combination of power, portability, and advanced features, making it an excellent choice for anyone looking to achieve a flawless finish. Its blend of practicality and efficiency caters to a wide range of applications, helping both novice and experienced users achieve outstanding results with ease. Whether tackling a home renovation or a professional job, this paint sprayer is designed to meet various painting needs effectively.