•Reference numbers and letters in parentheses in the text refer to numbers and letters in the illustrations.
•Be sure all accessories are adequately sized and
•To protect the screens from paints and solvents,
To prevent tipping which can cause serious injury and equipment damage, the mounting stand must be securely anchored to the floor or to an appropriate base. The stand is not intended for
Mounting the PD2K Base Unit:
•Mount the PD2K in a
•Ensure that the mounting surface and mounting hardware are strong enough to support the weight of the equipment, fluid, hoses, and stress caused during operation.
•Do not mount to a wall.
•Secure the stand to the floor with 1/2 in. (13 mm) bolts which engage at least 6 in. (152 mm) into the floor to prevent the unit from tipping. See Dimensions, page 36.
•There must be sufficient space on all sides of the equipment for installation, operator access, maintenance, and air circulation. The fans at the back of the unit require a minimum of 6 in. (152 mm) clearance from the closest surface to ensure adequate air circulation.