1. Use the screws (11) to mount the bracket (10) for the Advanced Display Module (12) on the front of the Control Box or on the wall.

2. Snap the Advanced Display Module into the bracket.

Figure 9 Install Display Module

3.Connect one end of the 5 ft (1.5 m) CAN cable (provided) to the Advanced Display Module

(M). The other end of the cable comes from the factory connected to the Enhanced Fluid Control Module (EFCM).

NOTE: For a list of alternate cable lengths, see Electrical Schematics, page 29. The total length of all cable used in the system must not exceed 150 ft (45 m).

Figure 10 Advanced Display Module Connection Ports

Item

Description

J

Battery Cover

K

Model Number

L

USB Drive Interface

M

CAN Cable Connection

N

ADM Status LEDs

P

Accessory Cable

 

Connection

R

Token Access Cover

 

 

332458B

19

Image 19
Contents ProMix PD2K Proportioner for Automatic Spray Applications Important Safety InstructionsRelated Manuals Contents0359 ModelsModel AC2000 High Pressure Identification Label Electric Shock Hazard Fire and Explosion HazardToxic Fluid or Fumes Intrinsic SafetySkin Injection Hazard Moving Parts HazardEquipment Misuse Hazard Personal Protective EquipmentChanging Materials Important Isocyanate ISO InformationIsocyanate Conditions Moisture Sensitivity of IsocyanatesLength ft m System Control Drawing 16P577Hazardous Classified Location NON-HAZARDOUS Location onlySelect a Base Model Configure Your SystemComponent Description Hazardous Classified Location NON-HAZARDOUS Location only Typical InstallationViscosity Ratio Resin a Catalyst B Select HosesHose Selection Tool Recommended Hose Sizes internal diameter for a and BSpray Guns Select a Spray GunApplication Gun Model Gun Manual No Low Pressure Circulating Kits Select Non- is Color and Catalyst Change KitsKit Part No Kit Description Color + Solvent Valves Select is Remote Color Change KitsSelect Pump Expansion Kits Mounting the PD2K Base Unit General InformationAdvanced Display Module Connection Ports Install the Display ModuleKey Connection Description Air SupplyAir Requirements Air ConnectionsFluid Requirements Fluid SupplyColor Change Connections Single Color ConnectionsCatalyst 35 cc pumps Repeat for the lower throat cartridge TSL Cup KitLight Tower Accessory Solvent Meter AccessoryElectrical Connections Wire KeyElectrical Supply Electrical RequirementsGrounding Key Hazardous Location NON-HAZARDOUS LocationSolvent Reservoir or Purge Station Object Being SprayedCheck Resistance Power Module Electrical SchematicsEfcm Efcm J8 J9 J15 J16 J14 J10 J15 J16 Electrical Schematic, Sheet 3, Hazardous Location Optional Cables Modules Dimensions Positive Displacement Metric Proportioner Technical DataGraco Information Graco Standard Warranty