Graco 332458B important safety instructions Fire and Explosion Hazard, Electric Shock Hazard

Page 5

Warnings

Warnings

The following warnings are for the setup, use, grounding, maintenance and repair of this equipment. The exclamation point symbol alerts you to a general warning and the hazard symbol refers to procedure-specific risks. When these symbols appear in the body of this manual or on warning labels, refer back to these Warnings. Product-specific hazard symbols and warnings not covered in this section may appear throughout the body of this manual where applicable.

WARNING

FIRE AND EXPLOSION HAZARD

Flammable fumes, such as solvent and paint fumes, in work area can ignite or explode. To help prevent fire and explosion:

Use equipment only in well ventilated area.

Eliminate all ignition sources; such as pilot lights, cigarettes, portable electric lamps, and

plastic drop cloths (potential static arc).

• Keep work area free of debris, including solvent, rags and gasoline.

• Do not plug or unplug power cords, or turn power or light switches on or off when flammable fumes are present.

• Ground all equipment in the work area. See Grounding instructions.

Use only grounded hoses.

Hold gun firmly to side of grounded pail when triggering into pail. Do not use pail liners unless they are antistatic or conductive.

Stop operation immediately if static sparking occurs or you feel a shock, Do not use equipment until you identify and correct the problem.

Keep a working fire extinguisher in the work area.

ELECTRIC SHOCK HAZARD

This equipment must be grounded. Improper grounding, setup, or usage of the system can cause electric shock.

Turn off and disconnect power at main switch before disconnecting any cables and before servicing or installing equipment.

Connect only to grounded power source.

All electrical wiring must be done by a qualified electrician and comply with all local codes and regulations.

332458B

5

Image 5
Contents ProMix PD2K Proportioner for Automatic Spray Applications Important Safety InstructionsRelated Manuals Contents0359 ModelsModel AC2000 High Pressure Identification Label Electric Shock Hazard Fire and Explosion HazardSkin Injection Hazard Intrinsic SafetyMoving Parts Hazard Toxic Fluid or FumesEquipment Misuse Hazard Personal Protective EquipmentIsocyanate Conditions Important Isocyanate ISO InformationMoisture Sensitivity of Isocyanates Changing MaterialsLength ft m System Control Drawing 16P577Hazardous Classified Location NON-HAZARDOUS Location onlyComponent Description Configure Your SystemSelect a Base Model Hazardous Classified Location NON-HAZARDOUS Location only Typical InstallationHose Selection Tool Select HosesRecommended Hose Sizes internal diameter for a and B Viscosity Ratio Resin a Catalyst BApplication Gun Model Gun Manual No Select a Spray GunSpray Guns Kit Part No Kit Description Select Non- is Color and Catalyst Change KitsLow Pressure Circulating Kits Color + Solvent Valves Select is Remote Color Change KitsSelect Pump Expansion Kits Mounting the PD2K Base Unit General InformationAdvanced Display Module Connection Ports Install the Display ModuleAir Requirements Air SupplyAir Connections Key Connection DescriptionFluid Requirements Fluid SupplyColor Change Connections Single Color ConnectionsCatalyst 35 cc pumps Repeat for the lower throat cartridge TSL Cup KitLight Tower Accessory Solvent Meter AccessoryElectrical Supply Wire KeyElectrical Requirements Electrical ConnectionsGrounding Key Hazardous Location NON-HAZARDOUS LocationCheck Resistance Object Being SprayedSolvent Reservoir or Purge Station Power Module Electrical SchematicsEfcm Efcm J8 J9 J15 J16 J14 J10 J15 J16 Electrical Schematic, Sheet 3, Hazardous Location Optional Cables Modules Dimensions Positive Displacement Metric Proportioner Technical DataGraco Information Graco Standard Warranty