Graco 332458B important safety instructions System Control Drawing 16P577, Length ft m

Page 9

System Control Drawing 16P577

System Control Drawing 16P577

Do not substitute or modify system components as this may impair intrinsic safety. For installation, maintenance, or operation instructions, read instruction manuals. Do not install equipment approved only for non-hazardous location in a hazardous location. See the identification label for the intrinsic safety rating for your model.

NOTES FOR SYSTEM CONTROL DRAWING 16P577 (FM13ATEX0026 SYSTEM ASSEMBLY CERTIFICATE)

Alternate M12 CAN Cables, for Hazardous Locations

Cable Part No.

16V423

16V424

16V425

16V426

16V427

16V428

16V429

16V430

Length ft (m)

2.0(0.6)

3.0(1.0)

6.0(2.0)

10.0(3.0)

15.0(5.0)

25.0(8.0)

50.0(16.0)

100.0(32.0)

2.The non-intrinsically safe terminals (power rail) must not be connected to any device which uses or generates more than Um = 250 Vrms or dc unless it has been determined that the voltage has been adequately isolated.

3.The electrical enclosure ground screw must be connected to a true earth ground using the supplied ground strap (223547) or by an equivalent 10 AWG or larger isolated conductor. Resistance from the electrical enclosure ground to the true earth ground shall not exceed 1 ohm.

4.Multiple earthing of components is allowed. Intrinsically safe apparatus provides isolation from earth to

500Vrms.

Do not operate system with power barrier cover removed.

6.Installation should be in accordance with ANSI/ISA RP12.06.01 “Installation of Intrinsically Safe Systems for Hazardous (Classified) Locations” and the National Electrical Code® (ANSI/NFPA 70).

7.Installation in Canada should be in accordance with the Canadian Electrical Code, CAS C22.1, Part I, Appendix F.

8.For ATEX, install per EN 60079–14 and applicable local and national codes.

9.For IECEx install per IEC 60079–14 and applicable local and national codes.

332458B

9

Image 9
Contents ProMix PD2K Proportioner for Automatic Spray Applications Important Safety InstructionsRelated Manuals Contents0359 ModelsModel AC2000 High Pressure Identification Label Electric Shock Hazard Fire and Explosion HazardSkin Injection Hazard Intrinsic SafetyMoving Parts Hazard Toxic Fluid or FumesEquipment Misuse Hazard Personal Protective EquipmentIsocyanate Conditions Important Isocyanate ISO InformationMoisture Sensitivity of Isocyanates Changing MaterialsLength ft m System Control Drawing 16P577Hazardous Classified Location NON-HAZARDOUS Location onlyConfigure Your System Select a Base ModelComponent Description Hazardous Classified Location NON-HAZARDOUS Location only Typical InstallationHose Selection Tool Select HosesRecommended Hose Sizes internal diameter for a and B Viscosity Ratio Resin a Catalyst BSelect a Spray Gun Spray GunsApplication Gun Model Gun Manual No Select Non- is Color and Catalyst Change Kits Low Pressure Circulating KitsKit Part No Kit Description Color + Solvent Valves Select is Remote Color Change KitsSelect Pump Expansion Kits Mounting the PD2K Base Unit General InformationAdvanced Display Module Connection Ports Install the Display ModuleAir Requirements Air SupplyAir Connections Key Connection DescriptionFluid Requirements Fluid SupplyColor Change Connections Single Color ConnectionsCatalyst 35 cc pumps Repeat for the lower throat cartridge TSL Cup KitLight Tower Accessory Solvent Meter AccessoryElectrical Supply Wire KeyElectrical Requirements Electrical ConnectionsGrounding Key Hazardous Location NON-HAZARDOUS LocationObject Being Sprayed Solvent Reservoir or Purge StationCheck Resistance Power Module Electrical SchematicsEfcm Efcm J8 J9 J15 J16 J14 J10 J15 J16 Electrical Schematic, Sheet 3, Hazardous Location Optional Cables Modules Dimensions Positive Displacement Metric Proportioner Technical DataGraco Information Graco Standard Warranty