Graco 332458B TSL Cup Kit, Catalyst 35 cc pumps Repeat for the lower throat cartridge

Page 23

TSL Cup Kit

TSL Cup Kit

Throat Seal Liquid (TSL) lubricates the pump throat packings and dosing valves. The PD2K Proportioner includes two TSL Cup Kits, one for each pump. The kits supply TSL to the upper throat cartridge of the color (70 cc) pump, to the upper and lower throat cartridges of the catalyst (35 cc) pump, and to the four pump dosing valves.

NOTE: TSL must be ordered separately. Order Part No. 206995, 1 quart (0.95 liter).

1.Slide the kit mounting bracket (73a) onto any side of the pump’s hex nut.

2.Place the TSL cup (73) into the bracket (73a). Routing of the throat seal tubing (73c) should always slope up to the reservoir.

NOTE: The pump’s upper throat cartridge has three ports (two are plugged). Move a plug (73d) if necessary so the barbed fitting (73b) can be put in the port closest to the TSL cup.

3.Check that the o-ring is in place on the barbed fitting (73b). Apply low strength thread adhesive and install the fitting in the upper throat cartridge port. Be sure the other two ports are plugged (73d).

4. Catalyst (35 cc) pumps: Repeat for the lower throat cartridge.

Figure 13 Install TSL Cup Kit

332458B

23

Image 23
Contents ProMix PD2K Proportioner for Automatic Spray Applications Important Safety InstructionsRelated Manuals Contents0359 ModelsModel AC2000 High Pressure Identification Label Electric Shock Hazard Fire and Explosion HazardToxic Fluid or Fumes Intrinsic SafetySkin Injection Hazard Moving Parts HazardEquipment Misuse Hazard Personal Protective EquipmentChanging Materials Important Isocyanate ISO InformationIsocyanate Conditions Moisture Sensitivity of IsocyanatesLength ft m System Control Drawing 16P577Hazardous Classified Location NON-HAZARDOUS Location onlyComponent Description Configure Your SystemSelect a Base Model Hazardous Classified Location NON-HAZARDOUS Location only Typical InstallationViscosity Ratio Resin a Catalyst B Select HosesHose Selection Tool Recommended Hose Sizes internal diameter for a and BApplication Gun Model Gun Manual No Select a Spray GunSpray Guns Kit Part No Kit Description Select Non- is Color and Catalyst Change KitsLow Pressure Circulating Kits Color + Solvent Valves Select is Remote Color Change KitsSelect Pump Expansion Kits Mounting the PD2K Base Unit General InformationAdvanced Display Module Connection Ports Install the Display ModuleKey Connection Description Air SupplyAir Requirements Air ConnectionsFluid Requirements Fluid SupplyColor Change Connections Single Color ConnectionsCatalyst 35 cc pumps Repeat for the lower throat cartridge TSL Cup KitLight Tower Accessory Solvent Meter AccessoryElectrical Connections Wire KeyElectrical Supply Electrical RequirementsGrounding Key Hazardous Location NON-HAZARDOUS LocationCheck Resistance Object Being SprayedSolvent Reservoir or Purge Station Power Module Electrical SchematicsEfcm Efcm J8 J9 J15 J16 J14 J10 J15 J16 Electrical Schematic, Sheet 3, Hazardous Location Optional Cables Modules Dimensions Positive Displacement Metric Proportioner Technical DataGraco Information Graco Standard Warranty