Graco 332458B important safety instructions Solvent Meter Accessory, Light Tower Accessory

Page 24

Solvent Meter Accessory

5.If you are lubricating the dosing valves, remove the plug (73d) and gasket from the valve port (V) closest to the TSL cup. Check that the o-ring is in place on the barbed fitting (73b). Apply low strength thread adhesive and install the fitting in the valve port (V). NOTE: Do not confuse the valve port (V) with the air port (W).

NOTE: If you are not lubricating the dosing valves, remove the unused barbed fittings (73b) from the bottom of the TSL cup (73). Apply low strength thread adhesive and install the plugs and gaskets supplied with the kit.

6.Cut the tubing (73c) to length as required. Connect the TSL cup fittings to the fittings on the pump and valves. TSL is gravity-fed from the cup to the pump and valves; position the fittings and tubing to prevent kinks and enable the TSL to flow freely.

7.Fill the cup with TSL.

NOTE: If TSL leaks from the rod guard of the color (70 cc) pump, be sure the lower u-cup seal is installed in the lower throat cartridge.

Solvent Meter Accessory

To install Solvent Meter Kit 280555, see manual 308778.

NOTE: Install the solvent meter downstream of the solvent cutoff switch near the base unit.

Light Tower Accessory

To install Light Tower Kit 24K337, see manual 3A1906.

24

332458B

Image 24
Contents Important Safety Instructions ProMix PD2K Proportioner for Automatic Spray ApplicationsContents Related ManualsModels 0359Model AC2000 High Pressure Identification Label Fire and Explosion Hazard Electric Shock HazardIntrinsic Safety Skin Injection HazardMoving Parts Hazard Toxic Fluid or FumesPersonal Protective Equipment Equipment Misuse HazardImportant Isocyanate ISO Information Isocyanate ConditionsMoisture Sensitivity of Isocyanates Changing MaterialsSystem Control Drawing 16P577 Length ft mNON-HAZARDOUS Location only Hazardous Classified LocationConfigure Your System Select a Base ModelComponent Description Typical Installation Hazardous Classified Location NON-HAZARDOUS Location onlySelect Hoses Hose Selection ToolRecommended Hose Sizes internal diameter for a and B Viscosity Ratio Resin a Catalyst BSelect a Spray Gun Spray GunsApplication Gun Model Gun Manual No Select Non- is Color and Catalyst Change Kits Low Pressure Circulating KitsKit Part No Kit Description Select is Remote Color Change Kits Color + Solvent ValvesSelect Pump Expansion Kits General Information Mounting the PD2K Base UnitInstall the Display Module Advanced Display Module Connection PortsAir Supply Air RequirementsAir Connections Key Connection DescriptionFluid Supply Fluid RequirementsSingle Color Connections Color Change ConnectionsTSL Cup Kit Catalyst 35 cc pumps Repeat for the lower throat cartridgeSolvent Meter Accessory Light Tower AccessoryWire Key Electrical SupplyElectrical Requirements Electrical ConnectionsGrounding Hazardous Location NON-HAZARDOUS Location KeyObject Being Sprayed Solvent Reservoir or Purge StationCheck Resistance Electrical Schematics Power ModuleEfcm Efcm J8 J9 J15 J16 J14 J10 J15 J16 Electrical Schematic, Sheet 3, Hazardous Location Optional Cables Modules Dimensions Technical Data Positive Displacement Metric ProportionerGraco Standard Warranty Graco Information