Graco Inc 1595 Premium Hi-Boy, 695 Premium Hi-Boy Check to see if transducer and control board

Page 14

Troubleshooting

TYPE OF PROBLEM

WHAT TO CHECK

 

HOW TO CHECK

 

 

 

 

Sprayer does not run at all

Check transducer or transducer

1.

Set sprayer to OFF and disconnect power to

 

connections (control board is not

 

sprayer.

Digital display shows E=03

 

detecting a pressure signal).

 

 

 

2.

Check transducer and connections to control board.

 

 

 

 

3.

Disconnect transducer from control board socket.

 

 

 

Check to see if transducer and control board

 

 

 

contacts are clean and secure.

Control board status light blinks

 

 

 

 

 

3 times repeatedly

 

4.

Reconnect transducer to control board socket.

 

 

 

Connect power, set sprayer ON and control knob

 

 

 

to 1/2 turn clockwise. If sprayer does not run,

 

 

 

set sprayer to OFF and go to next step.

 

 

5.

Connect a confirmed working transducer to control

 

 

 

board socket.

 

 

6.

Set sprayer ON and control knob to 1/2 turn

 

 

 

clockwise. If sprayer runs, install new transducer.

 

 

 

Replace control board if sprayer does not run.

 

 

7.

Check transducer resistance with ohmmeter (less

 

 

 

than 9k ohm between red and black wires and 3-6k

 

 

 

ohm between green and yellow wires).

 

 

 

 

14

3A0157A

Image 14
Contents Electric Airless Sprayers MarkModels Ultra MAX lIlTable of Contents Grounding Instructions GroundingFire and Explosion Hazard Skin Injection HazardPressurized Aluminum Parts Hazard Equipment Misuse HazardElectric Shock Hazard Moving Parts HazardComponent Identification Pressure Relief Procedure Pails Power RequirementsGrounding Extension CordMechanical/Fluid Flow TroubleshootingWhat to Check What to do Type of Problem Follow Pressure Relief Procedure on What to Check What to do Type of Problem Type of Problem What to Check HOW to Check ElectricalCheck to see if transducer and control board Step Check Motor Thermal Switch Unplug thermal Is not correct, replace motor Sprayer Will Not Shut Off YESSprayer Will Not Run Step Removal Installation VAC and 110 VAC Motor Control Board33 D 115 VAC Filter Board RemovalPressure Adjust Potentiometer Pressure Control Transducer Install control box 61 and control panel 68 with four screws 3A0157A Assembly Drive and Bearing Housing ReplacementDisassembly Drive and Bearing Housing Replacement Removal Motor ReplacementInstallation Motor Replacement Displacement Pump Replacement for 695/795/Mark Perform Relieve Pressure ProcedureTi7169a Displacement Pump Replacement 1095/1595/Mark Perform Pressure Relief Procedure,Place u-bolt on pump door protrusion Attach drain hose to sprayer Hose Reel Grease shaft Install swivel Reed Switch Replacement Removal InstallationWiring Diagram 120V Models120V Models with 15/20 Amp Switch 240V Models 3A0157A Graco Standard Warranty For Graco Canada Customers