Grounding

The sprayer must be grounded. Grounding reduces the risk of static and electric shock by providing an escape wire for the electrical current due to static build up or in the event of a short circuit.

The sprayer cord includes a grounding wire with an appropriate grounding contact.

The plug must be plugged into an outlet that is properly installed and grounded in accordance with all local codes and ordinances.

Grounding

Pails

Solvent and oil/based fluids: follow local code. Use only conductive metal pails, placed on a grounded sur- face such as concrete.

Do not place pail on a nonconductive surface such as paper or cardboard which interrupts grounding continu- ity.

ti2810a

ti4297a

Do not modify plug! Tampering with the plug will result in a voided warranty. If plug will not fit in outlet, have grounded outlet installed by a qualified electrician. Do not use an adapter.

Power Requirements

100-120V units require 100-120 VAC, 50/60 Hz, 15A, 1 phase.

230V units require 230 VAC, 50/60 HZ, 10A,

1 phase.

Extension Cord

Use an extension cord with an undamaged ground con- tact. If an extension cord is necessary, use a 3-wire, 12

AWG (2.5 mm2) minimum.

Ground

120 volt plug

ti5850a

Grounding a metal pail: connect a ground wire to the pail by clamping one end to pail and other end to a true earth ground.

ti14840a

To maintain grounding continuity when flushing or relieving pressure: hold metal part of spray gun firmly to side of a grounded metal pail. Then trigger gun.

ti13243a

3A0157A

9

Image 9
Contents Mark Electric Airless SprayersUltra MAX lIl ModelsTable of Contents Grounding Grounding InstructionsSkin Injection Hazard Fire and Explosion HazardElectric Shock Hazard Equipment Misuse HazardPressurized Aluminum Parts Hazard Moving Parts HazardComponent Identification Pressure Relief Procedure Grounding Power RequirementsPails Extension CordTroubleshooting What to Check What to do Type of ProblemMechanical/Fluid Flow Follow Pressure Relief Procedure on What to Check What to do Type of Problem Electrical Type of Problem What to Check HOW to CheckCheck to see if transducer and control board Step Check Motor Thermal Switch Unplug thermal Is not correct, replace motor YES Sprayer Will Not Shut OffSprayer Will Not Run Step VAC and 110 VAC Motor Control Board Removal Installation33 D 115 Removal VAC Filter BoardPressure Adjust Potentiometer Pressure Control Transducer Install control box 61 and control panel 68 with four screws 3A0157A Drive and Bearing Housing Replacement DisassemblyAssembly Drive and Bearing Housing Replacement Motor Replacement InstallationRemoval Motor Replacement Perform Relieve Pressure Procedure Displacement Pump Replacement for 695/795/MarkTi7169a Perform Pressure Relief Procedure, Displacement Pump Replacement 1095/1595/MarkPlace u-bolt on pump door protrusion Attach drain hose to sprayer Hose Reel Grease shaft Install swivel Removal Installation Reed Switch Replacement120V Models Wiring Diagram120V Models with 15/20 Amp Switch 240V Models 3A0157A For Graco Canada Customers Graco Standard Warranty