Graco Inc 1095 Premium Hi-Boy, 695 Premium Hi-Boy, 795 Premium Hi-Boy Pressure Relief Procedure

Page 8

Pressure Relief Procedure

Pressure Relief Procedure

1.Turn power OFF. Wait 7 seconds for power to dissipate.

ti4265a

2.Lock gun trigger safety. Remove guard and SwitchTip.

ti10166ati2769a

3.Turn pressure to lowest setting. Trigger gun to relieve pressure.

-

ti14841a

 

4.Put drain tube in pail. Turn prime valve down to DRAIN position.

ti14842a

ti2595a

8

3A0157A

Image 8
Contents Electric Airless Sprayers MarkModels Ultra MAX lIlTable of Contents Grounding Instructions GroundingFire and Explosion Hazard Skin Injection HazardEquipment Misuse Hazard Electric Shock HazardPressurized Aluminum Parts Hazard Moving Parts HazardComponent Identification Pressure Relief Procedure Power Requirements GroundingPails Extension CordMechanical/Fluid Flow TroubleshootingWhat to Check What to do Type of Problem Follow Pressure Relief Procedure on What to Check What to do Type of Problem Type of Problem What to Check HOW to Check ElectricalCheck to see if transducer and control board Step Check Motor Thermal Switch Unplug thermal Is not correct, replace motor Sprayer Will Not Shut Off YESSprayer Will Not Run Step Removal Installation VAC and 110 VAC Motor Control Board33 D 115 VAC Filter Board RemovalPressure Adjust Potentiometer Pressure Control Transducer Install control box 61 and control panel 68 with four screws 3A0157A Assembly Drive and Bearing Housing ReplacementDisassembly Drive and Bearing Housing Replacement Removal Motor ReplacementInstallation Motor Replacement Displacement Pump Replacement for 695/795/Mark Perform Relieve Pressure ProcedureTi7169a Displacement Pump Replacement 1095/1595/Mark Perform Pressure Relief Procedure,Place u-bolt on pump door protrusion Attach drain hose to sprayer Hose Reel Grease shaft Install swivel Reed Switch Replacement Removal InstallationWiring Diagram 120V Models120V Models with 15/20 Amp Switch 240V Models 3A0157A Graco Standard Warranty For Graco Canada Customers