Spray Tip Selection Chart
RAC SwitchTips, for use with AA Series Air Cap
All tips in the Spray Tip Selection Charts below can be used with Model 249238 G40 guns equipped with RAC air cap 249478.
LTX RAC Spray Tips
Order desired tip (Part No. LTXxxx) from matrix below.
Tips are sometimes packaged with other promo- tional parts intended for the airless market. Disre- gard extra parts.
| * Fluid Output, fl oz/min (lpm) |
|
| ❖ Maximum Pattern Width at 12 in. (305 mm) |
|
| ||||
Orifice Size in. |
|
|
|
|
|
|
|
|
|
|
at 2000 psi | 2 to 4 | 4 to 6 | 6 to 8 | 8 to 10 | 10 to 12 | 12 to 14 | 14 to 16 | 16 to 18 | 18 to 20 | |
(mm) | (14.0 MPa, 140 bar) | (100) | (150) | (200) | (250) | (300) | (350) | (400) | (450) | (500) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
0.009 (0.229) | 11.2 (0.33) |
| 209 | 309 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
0.011 (0.279) | 16.6 (0.49) |
| 211 | 311 | 411 | 511 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
0.013 (0.330) | 23.3 (0.69) |
| 213 | 313 | 413 | 513 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
0.015 (0.381) | 30.8 (0.91) |
| 215 | 315 | 415 | 515 | 615 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
0.017 (0.432) | 39.5 (1.17) |
| 217 | 317 | 417 | 517 | 617 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
0.019 (0.483) | 49.7 (1.47) |
| 219 | 319 | 419 | 519 | 619 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
0.021 (0.533) | 60.5 (1.79) |
|
| 321 | 421 | 521 | 621 | 721 |
|
|
|
|
|
|
|
|
|
|
|
|
|
0.023 (0.584) | 72.7 (2.15) |
|
|
| 423 | 523 | 623 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
0.025 (0.635) | 85.9 (2.54) |
|
|
|
| 525 | 625 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
0.027 (0.686) | 100.0 (2.96) |
|
|
|
| 527 | 627 |
| 827 |
|
|
|
|
|
|
|
|
|
|
|
|
0.029 (0.737) | 115.6 (3.42) |
|
|
|
|
| 629 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
0.031 (0.787) | 131.8 (3.90) |
|
|
|
| 531 | 631 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
0.033 (0.838) | 149.4 (4.42) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
0.035 (0.889) |
|
|
|
|
| 535 | 635 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
*Tips are tested in water.
Fluid output (Q) at other pressures (P) can be calculated by this formula: Q = (0.041) (QT) P where QT = fluid output (fl oz/min) from the above table for the selected orifice size.
❖Measured with NO airflow. Air assist will tend to reduce pattern lengths by 1 in. to 2 in.
311001C | 31 |