Graco Inc 311001C Technical Data, Category Data, Gun Inlet Pressure PSI

Page 34

Technical Data

Technical Data

Category

Data

Maximum Working Fluid Pressure

Model G15: 1500 psi (10 MPa, 105 bar)

 

Model G40: 4000 psi (28 MPa, 280 bar)

Maximum Working Air Pressure

100 psi (0.7 MPa, 7 bar)

Maximum Gun Inlet Air Pressure for HVLP Operation . . .

14 psi (0.098 MPa, 0.98 bar)

Maximum Working Fluid Temperature

110°F (43°C)

Fluid Inlet

1/4-18 npsm

Air Inlet

1/4-18 npsm (R1/4-19) compound male thread

Gun Weight

16 oz (450 grams)

*Sound Pressure at 20 psi (140 kPa, 1.4 bar)

66.9 dB(A)

*Sound Pressure at 100 psi (0.7 kPa, 7 bar)

80.0 dB(A)

*Sound Power at 20 psi (140 kPa, 1.4 bar)

76.8 dB(A)

*Sound Power at 100 psi (0.7 kPa, 7 bar)

89.9 dB(A)

Wetted Parts

Stainless Steel, Carbide, Ultra High Molecular Weight

 

Polyethylene, Acetal, PTFE, Nylon, Flouroelastomer

*All readings were taken with the fan valve fully closed (full fan size), at 20 psi (140 kPa, 1.4 bar) and 100 psi (0.7 kPa, 7 bar), and at the assumed operator position. Sound Power was tested to ISO 9614-2.

 

12

 

10

 

8

Air Flow

6

(SCFM)

 

 

4

 

2

 

0

Air Flow, Standard AA Series Air Cap

10.6

8.6

6.4

5.8

4.2

4.6

3.8

2.6

0

10

20

30

40

50

 

 

Gun Inlet Pressure (PSI)

 

 

Fan Valve Open

Fan Valve Closed

34

311001C

Image 34
Contents Model G40 w/RAC tip Model G15Model G40 II 2 GContents ModelsRelated Manuals Fire and Explosion Hazard Pressurized Aluminum Parts Hazard Installation Typical Installation GroundingAir Line Fluid LineSetup Reverse-A-CleanRAC Tip Operation SafetyPressure Relief Procedure Trigger LockHow the Air-Assisted Spray Gun Operates Spray Pattern AdjustmentNo air Too little air correct amount Air Hvlp Operation Fluid ApplicationDaily Gun Care, Flushing, and Cleaning Fluid Filter Maintenance General System MaintenanceFlushing and Cleaning Connect the solvent supply hose T to the gun Clearing a clogged RAC tip Disengaged Follow Pressure Relief Procedure on page 10. Read warnings, TroubleshootingGeneral Troubleshooting Problem Cause SolutionTroubleshooting Repair Items Needed for ServiceFan Valve Replacement Repair KitsNeedle Repair 5g* 5c† 5d† 5b†13‡ 14‡ Fluid Tube Replacement Air Valve RepairRepair 311001C Reassembly 5b† G40 only 5c† 5d† Parts Part No. Description Qty Washer PtfePart No /G40 Gun w/RAC Tip TIP GUARD/AIR CAP Assy AAM Fine Finish Spray Tips Spray Tip Selection ChartSpray Tips, for use with AA Series Air Cap GG4 Industrial Spray TipsRAC SwitchTips, for use with AA Series Air Cap LTX RAC Spray TipsFFT Fine Finish RAC Spray Tips WRX WideRAC Spray TipsAccessories Category Data Technical Data10.6 Gun Inlet Pressure PSI Dimensions Graco Standard Warranty Graco Information