Graco Inc 311001C Spray Tip Selection Chart, Spray Tips, for use with AA Series Air Cap

Page 30

Spray Tip Selection Chart

Spray Tip Selection Chart

Spray Tips, for use with AA Series Air Cap

AAM Fine Finish Spray Tips

Recommended for high finish quality applications at low and medium pressures. Order desired tip (Part No. AAMxxx) from matrix below.

GG4 Industrial Spray Tips

Recommended for high wear applications at high pressures. Order desired tip (Part No. GG4xxx) from matrix below.

• All tips in the Spray Tip Selection Chart below can be used with Model G40 guns (249242). Use tips in the gray shaded area of the chart with Model G40 guns only.

Do not use tips in the gray shaded area of the chart with Model G15 guns (249233).

SKIN INJECTION HAZARD

Do not use tips in the gray shaded area of the Spray Tip Selection Chart with Model G15 guns (249233).

Failure to follow this warning can result in serious injury or amputation.

 

* Fluid Output, fl oz/min (lpm)

 

 

Maximum Pattern Width at 12 in. (305 mm)

 

 

Orifice Size in.

 

 

 

 

 

 

 

 

 

 

 

at 600 psi

at 1000 psi

2 to 4

4 to 6

6 to 8

8 to 10

10 to 12

12 to 14

14 to 16

16 to 18

18 to 20

(mm)

(4.1 MPa, 41 bar)

(7.0 MPa, 70 bar)

(100)

(150)

(200)

(250)

(300)

(350)

(400)

(450)

(500)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

† 0.007 (0.178)

4.0 (0.1)

5.2 (0.15)

107

207

307

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

† 0.009 (0.229)

7.0 (0.2)

9.1 (0.27)

109

209

309

409

509

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

† 0.011 (0.279)

10.0 (0.3)

13.0

(0.4)

111

211

311

411

511

611

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0.013 (0.330)

13.0 (0.4)

16.9

(0.5)

 

213

313

413

513

613

713

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0.015 (0.381)

17.0 (0.5)

22.0

(0.7)

 

215

315

415

515

615

715

815

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0.017 (0.432)

22.0 (0.7)

28.5

(0.85)

 

217

317

417

517

617

717

817

917

 

 

 

 

 

 

 

 

 

 

 

 

 

0.019 (0.483)

28.0 (0.8)

36.3

(1.09)

 

219

319

419

519

619

719

819

919

 

 

 

 

 

 

 

 

 

 

 

 

 

0.021 (0.533)

35.0 (1.0)

45.4

(1.36)

 

 

321

421

521

621

721

821

921

 

 

 

 

 

 

 

 

 

 

 

 

 

‡ 0.023 (0.584)

40.0 (1.2)

51.9

(1.56)

 

 

 

423

523

623

723

 

923

 

 

 

 

 

 

 

 

 

 

 

 

 

‡ 0.025 (0.635)

50.0 (1.5)

64.8

(1.94)

 

 

 

425

 

625

725

825

 

 

 

 

 

 

 

 

 

 

 

 

 

 

‡ 0.027 (0.686)

58.5 (1.7)

75.8

(2.27)

 

 

 

 

527

627

 

827

 

 

 

 

 

 

 

 

 

 

 

 

 

 

‡ 0.029 (0.737)

68.0 (1.9)

88.2

(2.65)

 

 

 

 

 

629

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

‡ 0.031 (0.787)

78.0 (2.2)

101.1 (3.03)

 

 

 

431

 

631

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

‡ 0.033 (0.838)

88.0 (2.5)

114.1 (3.42)

 

 

 

 

 

633

 

833

 

 

 

 

 

 

 

 

 

 

 

 

 

‡ 0.035 (0.889)

98.0 (2.8)

127.1 (3.81)

 

 

 

435

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

‡ 0.037 (0.940)

108.0 (3.1)

140.0 (4.20)

 

 

 

 

 

 

737

 

 

 

 

 

 

 

 

 

 

 

 

 

 

‡ 0.039 (0.991)

118.0 (3.4)

153.0 (4.59)

 

 

 

 

539

639

 

839

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*Tips are tested in water.

Fluid output (Q) at other pressures (P) can be calculated by this formula: Q = (0.041) (QT) P where QT = fluid output (fl oz/min) from the above table for the selected orifice size.

These tip sizes include a 150 mesh tip filter.

Do not use these tips with Model G15 guns (249233). GG4 tips only.

30

311001C

Image 30
Contents Model G40 w/RAC tip Model G15Model G40 II 2 GContents ModelsRelated Manuals Fire and Explosion Hazard Pressurized Aluminum Parts Hazard Installation Typical Installation GroundingAir Line Fluid LineSetup Reverse-A-CleanRAC Tip Operation SafetyPressure Relief Procedure Trigger LockSpray Pattern Adjustment How the Air-Assisted Spray Gun OperatesNo air Too little air correct amount Air Hvlp Operation Fluid ApplicationDaily Gun Care, Flushing, and Cleaning General System Maintenance Fluid Filter MaintenanceFlushing and Cleaning Connect the solvent supply hose T to the gun Clearing a clogged RAC tip Disengaged Follow Pressure Relief Procedure on page 10. Read warnings, TroubleshootingGeneral Troubleshooting Problem Cause SolutionTroubleshooting Repair Items Needed for ServiceFan Valve Replacement Repair Kits5g* 5c† 5d† 5b† Needle Repair13‡ 14‡ Fluid Tube Replacement Air Valve RepairRepair 311001C Reassembly 5b† G40 only 5c† 5d† Parts Part No. Description Qty Washer PtfePart No /G40 Gun w/RAC Tip TIP GUARD/AIR CAP Assy AAM Fine Finish Spray Tips Spray Tip Selection ChartSpray Tips, for use with AA Series Air Cap GG4 Industrial Spray TipsRAC SwitchTips, for use with AA Series Air Cap LTX RAC Spray TipsFFT Fine Finish RAC Spray Tips WRX WideRAC Spray TipsAccessories Technical Data Category Data10.6 Gun Inlet Pressure PSI Dimensions Graco Standard Warranty Graco Information