Graco Inc 311001C important safety instructions Setup

Page 8

Setup

Flush Before Using Equipment

1.The equipment was tested with lightweight oil, which is left in the fluid passages to protect parts. To avoid contaminating your fluid with oil, flush the equipment with a compatible solvent before using the equip- ment. See Flushing and Cleaning, page 14.

2.Relieve the pressure. See Pressure Relief Proce- dure, page 10.

Select a Spray Tip and Air Cap

The fluid flow and pattern width depend on the size of the spray tip, the fluid viscosity, and the fluid pressure. See Spray Tip Selection Chart, page 30. Contact your Graco distributor for assistance in selecting an appropri- ate spray tip for your application.

Install a Spray Tip

Install a spray tip in the gun. Ensure that the tip locating tab is positioned in the slot of the air cap. See FIG. 5. Tighten the air cap retaining ring (6) firmly by hand to ensure a good seal between the tip gasket and the dif- fuser (5).

Slot

 

Tip Locating Tab

TI6847A

FIG. 5

Position the Air Cap

The air cap and spray tip position determines the direc- tion of the spray pattern.

Rotate the air cap (the spray tip rotates with it) as needed to achieve the desired spray pattern direction. See FIG. 6.

Setup

TI6558A

FIG. 6

Air Cap Alignment Pin

Model G15 guns (249233) use an air cap alignment pin to position the air cap. The standard location of the air cap alignment pin is the horizontal air cap position.

If you would like to change the spray pattern direction, use a needle nose pliers to unscrew the pin and relocate it to the desired position. See FIG. 7. When relocating the pin use low-strength thread locker. Torque to 1.5-2.5 in-lb (0.2-0.3 N•m). DO NOT OVERTIGHTEN.

The air cap alignment pin can be removed according to preference.

Air cap alignment pins do not come standard with model G40 guns (249242).

TI6847A

Horizontal

Air Cap Position

(standard)

Vertical

Air Cap Position

FIG. 7

8

311001C

Image 8
Contents Model G15 Model G40Model G40 w/RAC tip II 2 GContents ModelsRelated Manuals Fire and Explosion Hazard Pressurized Aluminum Parts Hazard Installation Typical Installation GroundingAir Line Fluid LineSetup Reverse-A-CleanRAC Tip Safety Pressure Relief ProcedureOperation Trigger LockNo air Too little air correct amount Air Spray Pattern AdjustmentHow the Air-Assisted Spray Gun Operates Hvlp Operation Fluid ApplicationDaily Gun Care, Flushing, and Cleaning Flushing and Cleaning General System MaintenanceFluid Filter Maintenance Connect the solvent supply hose T to the gun Clearing a clogged RAC tip Disengaged Troubleshooting General TroubleshootingFollow Pressure Relief Procedure on page 10. Read warnings, Problem Cause SolutionTroubleshooting Items Needed for Service Fan Valve ReplacementRepair Repair Kits13‡ 14‡ 5g* 5c† 5d† 5b†Needle Repair Fluid Tube Replacement Air Valve RepairRepair 311001C Reassembly 5b† G40 only 5c† 5d† Parts Part No. Description Qty Washer PtfePart No /G40 Gun w/RAC Tip TIP GUARD/AIR CAP Assy Spray Tip Selection Chart Spray Tips, for use with AA Series Air CapAAM Fine Finish Spray Tips GG4 Industrial Spray TipsRAC SwitchTips, for use with AA Series Air Cap LTX RAC Spray TipsFFT Fine Finish RAC Spray Tips WRX WideRAC Spray TipsAccessories 10.6 Gun Inlet Pressure PSI Technical DataCategory Data Dimensions Graco Standard Warranty Graco Information