Carrier 48VT(N) installation instructions

Page 31
Manual background

O

T2 C C O

DFT

 

 

 

 

 

OF2

OF1

R

T1

 

 

 

 

 

 

 

 

W

 

 

 

 

 

 

 

 

 

2

 

 

 

 

 

 

 

 

 

Y

 

 

 

 

 

 

 

 

 

C

Y

 

 

 

 

 

 

 

 

SPEEDUP

P1

 

 

 

 

 

 

 

 

J1

P3

INTERVALTIMER

90

60 30

30 60

120

 

 

 

DFT

 

OFF

 

QUIET SHIFT

ON

 

 

 

Speedup

 

 

 

 

Quiet

Defrost interval

 

 

Pins

 

 

 

 

Shift

DIP switches

 

 

 

 

 

 

 

 

 

 

A08020

Fig. 23 - Defrost Control

48VT-- A

Copeland Scroll Compressor (Puron Refrigerant)

The compressor used in this product is specifically designed to operate with Puron (R-410A) refrigerant and cannot be interchanged.

The compressor is an electrical (as well as mechanical) device. Exercise extreme caution when working near compressors. Power should be shut off, if possible, for most troubleshooting techniques. Refrigerants present additional safety hazards.

!WARNING

EXPLOSION HAZARD

Failure to follow this warning could result in personal injury or death and/or property damage.

Wear safety glasses and gloves when handling refrigerants. Keep torches and other ignition sources away from refrigerants and oils.

The scroll compressor pumps refrigerant throughout the system by the interaction of a stationary and an orbiting scroll. The scroll compressor has no dynamic suction or discharge valves, and it is more tolerant of stresses caused by debris, liquid slugging, and flooded starts. The compressor is equipped with an internal pressure relief port. The pressure relief port is a safety device, designed to protect against extreme high pressure. The relief port has an operating range between 550 and 625 psi differential pressure.

31

Image 31
Contents Installation Instructions TABLE OF CONTENTSSAFETY CONSIDERATIONS Fig. 1 - Unit 48VT-AStep 2 - Provide Unit Support RECEIVING AND INSTALLATIONINTRODUCTION Step 1 - Check Equipment48VT--A Fig. 2 - 48VT-A24-30Unit DimensionsA09146 48VT--A Fig. 3 - 48VT-A36-60Unit DimensionsA09147 ROOF CURB DETAIL Fig. 4 - Roof Curb Dimensions48VT SMALL CURBRigging/Lifting of Unit See Fig ACCESS PANELS MUST BE IN PLACE WHEN RIGGINGStep 5 - Rig and Place Unit InspectionFig. 6 - Condensate Trap Step 7 - Install Flue HoodStep 8 - Install Gas Piping Step 6 - Connect Condensate DrainFIRE OR EXPLOSION HAZARD Step 9 - Install Duct ConnectionsConfiguring Units for Downflow Vertical Discharge Fig. 7 - Sediment TrapHorizontal Duct Covers Table 1 - Physical Data - Unit 48VT-AFig. 8 - Supply and Return Duct Opening 48VT--A48VT--A Table 1 - Physical Data - Unit 48VT-ACont’dTable 2 - Maximum Gas Flow Capacity Table 3 - Heating InputsControl Voltage Connections Step 10 - Install Electrical ConnectionsSpecial Procedures for 208-VOperation High-VoltageConnectionsThermostat Balance Point Setting-Thermidistator HybridPRE-START-UP Transformer ProtectionStep 2 - Unit Sequence of Operation Step 3 - Start-upHeating and Make Adjust- mentsSTART-UP Step 1 - Check for Refrigerant LeaksCheck Gas Input Adjust Gas InputFig. 11 - Burner Assembly Check Heating ControlAirflow and Temperature Rise Limit SwitchesCheck Burner Flame Normal OperationIndoor Airflow and Airflow Adjustments Step 4 - Start-upCooling and Make Adjust- mentsRollout Switch Checking and Adjusting Refrigerant Charge48VT--A Gas Heating Fan Speed Set-upContinuous Fan Operation Table 6 - Color Coding for Indoor Fan Motor LeadsTable 7 - Filter Pressure Drop Table IN. W.C Fig. 14 - Interface Fan Board IFBTable 8 - 48VT-AWet Coil Pressure Drop 48VT--AUNIT 48VT--AHeating 48VT--A1295 48VT--A1445 48VT--A1448 48VT--A48VT A Fig. 15 - 208/230-1-60Wiring Diagram, Unit 48VT-A48VT--A Fig. 16 - 208/230-3-60Wiring Diagram, Unit 48VT-AA09209 A09099 Fig. 17 - Cooling Charging Table-Subcooling48VT--A 50VT500173 REVIndoor Blower and Motor MAINTENANCECleaning the Blower Motor and Wheel Air FilterFig. 19 - Unit Access Panels Limit SwitchInduced Draft combustion air Blower Assembly Fig. 18 - Blower Housing and Flue Collector BoxFig. 20 - Removal of Motor and Blower Wheel Electrical Controls and WiringOutdoor Fan Refrigerant CircuitGas Input Pressure SwitchesLoss of Charge Switch High-PressureSwitchPage AccuraterMetering De vice HPS - High Pressure SwitchLCS - Loss of Charge Switch Fig. 24 - Refrigerant CircuitSynthetic Roof Precautionary Procedure TROUBLESHOOTINGSTART-UPCHECKLIST UNIT OPERATION AND SAFETY HAZARD48VT--A PURONR R-410AQUICK REFERENCE GUIDE48VT--A SYMPTOMTable 13 - Troubleshooting Guide-LEDStatus Codes Table 12 - Troubleshooting Guide-Heating48VT--A PRESSURES Remove and Store in Job FilesI. PRELIMINARY INFORMATION MODEL NO TEMPERATURESReplaces 48VT---04SI 48VT--ACatalog No 48VT---05SI Edition Date 04/09