3 - Technical features

Operating temperature : -104 °F to + 194 °F

C - Pre-filtration panels

Fig. 8

Easy to disassemble for rapid cleaning

1 - Description

Installing air filtration panels on the ventilation intakes (machine and built-in dryer) guarantees protection of the compressor's internal components and an increase in air sucked into the compression assembly. This option is recommended if the forced filtration option is installed (see § B).

2 - Option overview

The pre-filtration panels eliminate 90% of the particles normally admitted inside the compressor and considerably decrease internal contamination of the machine.

The high quality of the ventilation air is also essential for protecting internal components of the compressor and, more specifically, the motor and the air / air and air / oil exchangers. Clogging in the exchangers creates an increase in temperature, deterioration of the lubricant and the motor becomes overloaded thus increasing the energy consumed.

The quality of the air drawn in by a compressor is essential. Low quality air results in the following :

Fast pollution of the oil thus an increase in oil change cycles.

Increased pollution of the air and oil filtering components that increases the deterioration of the mechanical components in the compressor, screw block, ...

Binding of the air / oil separator before 6000 Hours thus an increase in maintenance cycles and maintenance costs.

Access to the filtering medium is allowed by removal that does not require any particular tool. The panel frame can be unlocked manually in order to clean the medium.

Exceptional longevity of the medium that is quick to take apart. The medium can be scoured by blowing compressed air in thus increasing the usage term for the filtering medium.

Galvanised steel covered frame.

Flammable medium (belonging to fire protection class M1) made of polyester fibres.

Pleated medium on support grid placed downwards in the direction of the airflow.

Support grid

Fig. 9

Pre-ventilation lock

2 pannels

15.75 in

Disassembly hinges

3 - Technical features

FILTER MEDIUM :

Degree of filtration : 90% of the dust emitted is filtered.

Total nominal flow :

324893 cfm/h

Filter panel number :

2

Initial charge loss :

75 Pa

Dimensions :

Width :

24 in

 

Length :

24 in

 

Thickness :

7.9 in

Chicago Pneumatic Compressors

01/2008

62 305 258 65

Page 13

Image 13
Contents Cpvs Model Cpvs 40 50 60Cpvs Model Mini + 36 F frost free Maxi + 104 FPSI NPTAWG Main Voltage 460 Volt / 3 / 60 HzConnection of the electric plate to an external control box Contents AIR Delivery Power SupplyGeneral Information DescriptionRespect of the environment and prevention of pollution Standard equipmentElectronic board Definition of the pictogramsInstallation Electric cabling Safety RegulationsVoltage Parallel compressor assembly Discharge pressure adjustmentSafety Preparation for start-upAir and oil circuits OperationKey fig Air circuits see FigLevel detection bleed valve Fig OptionsAdvanced filtration to the compression air inlet a and 7b Support grid Pre-filtration panelsFilter Medium Features Rotation direction indicator Phase controllerAutomatic restarting Remote starting and stoppingDescription of the option Centrifugal separator See B SectionSafety instructions InstallationSafety Rules Description cf SectionCommissioning Setting of pressure machinePreparation for start-up See Section Control of rotation direction on start upPressure regulation for low rates of flow Energy saving Principle of the pressure regulation by variable speedMain incidents Operating incidentsOperations to be carried out Parts MaintenanceObservations Air filter Oil level and change see figTurbine OillevelOil and air cooler Temperature safety testsOil separator see B Section Oil return pipe see figSee -E Main incidentsSupport@CPcompressor.com