Chicago Pneumatic CPVS 50, CPVS 60 Mini + 36 F frost free Maxi + 104 F, Cpvs Model, Psi, Npt

Page 2

The CP Compressors should never be operated beyond its capabilities or in any way which does not comply with the instructions contained in this operating and maintenance guide.

Chicago Pneumatic Compressors will decline any responsibility

if these instructions are not respected.

This equipment has been factory tested and satisfies normal

operating conditions: they must not be exceeded

as this would place the machine under abnormal stress and effort.

INSTALLATION INSTRUCTIONS

For the guarantee to be valid, the unit must be assembled in covered premises with temperatures not exceeding :

Mini: + 36 °F (frost free)

Maxi: + 104 °F

You must also have:

1 meter space around the compressor

-

low ventilation (fresh air) proportionate to the ventilation flow necessary for the machine and protected

from any infiltration of humidity (splashes of water during bad weather) and all pollution

-

top insulation or extraction to ensure reversal of the flow of warm air and evacuation of the heat to

outside the equipment room

-

a link from the condensation water evacuation pipe to the drain discharger

-

in dusty environment, pre-filtering the room's air intake and a special filter

on the machine's ventilation inlets

TECHNICAL DATA

VARIABLE SPEED MACHINES

CPVS Model

 

 

 

40

 

 

 

50

 

 

 

60

 

 

 

75

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VERSION CPVS (as per ISO 1217 ed 1996)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Nominal pressure at full flow

PSI

 

58

102

138

 

58

102

138

58

102

138

58

102

138

Actual flow*

cfm

 

195.1

194.5

166.4

 

239.1

234.1

204.4

291.2

280.2

244.7

374.3

342.3

304.8

Motor power

hp

 

 

40

 

 

 

50

 

 

 

60

 

 

 

75

 

Ø Pressure outlet (F)

NPT

 

 

1.5"

 

 

 

1.5"

 

 

 

1.5"

 

 

 

1.5"

 

Capacity

gal

 

 

5,8

 

 

 

5,8

 

 

 

5,8

 

 

 

5,8

 

Carryover

ppm

 

 

3

 

 

 

3

 

 

 

3

 

 

 

3

 

Noise level at 3,3ft

dB(A)

 

 

65

 

 

 

66

 

 

 

67

 

 

 

70

 

(according to ISO 2157 + 3db(A))

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

* Suction pressure : 14.5 PSI absolute - Relative humidity : 0 % - Ambient temperature : 68 °F

 

 

 

 

 

 

- Effective delivery pressure : 102 PSI, 109 PSI, 138 PSI or 181 PSI (effective)

 

 

 

 

 

 

 

 

 

Dimensions (in)

L x Wx H

 

75x37,4x69,3

 

75x37,4x69,3

 

75x37,4x69,3

 

75x37,4x69,3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Approximate weight

lbs

 

 

1874

 

 

 

1995

 

 

 

2226

 

 

 

2679

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

01/2008

Chicago Pneumatic Compressors

Page 2

62 305 258 65

Image 2
Contents Model Cpvs 40 50 60 CpvsPSI Mini + 36 F frost free Maxi + 104 FCpvs Model NPTConnection of the electric plate to an external control box Main Voltage 460 Volt / 3 / 60 HzAWG Contents Power Supply AIR DeliveryRespect of the environment and prevention of pollution DescriptionGeneral Information Standard equipmentDefinition of the pictograms Electronic boardInstallation Voltage Safety RegulationsElectric cabling Safety Discharge pressure adjustmentParallel compressor assembly Preparation for start-upKey fig OperationAir and oil circuits Air circuits see FigAdvanced filtration to the compression air inlet a and 7b OptionsLevel detection bleed valve Fig Filter Medium Pre-filtration panelsSupport grid Automatic restarting Rotation direction indicator Phase controllerFeatures Remote starting and stoppingCentrifugal separator See B Section Description of the optionSafety Rules InstallationSafety instructions Description cf SectionPreparation for start-up See Section Setting of pressure machineCommissioning Control of rotation direction on start upPrinciple of the pressure regulation by variable speed Pressure regulation for low rates of flow Energy savingOperating incidents Main incidentsObservations MaintenanceOperations to be carried out Parts Turbine Oil level and change see figAir filter OillevelOil separator see B Section Temperature safety testsOil and air cooler Oil return pipe see figMain incidents See -ESupport@CPcompressor.com