Chicago Pneumatic CPVS 50, CPVS 60, CPVS 40 Oil and air cooler, Oil separator see B Section

Page 22

D - Oil and air cooler

The aluminium oil and air cooler is a vital part in the CPVS system. Please take care of this element. To prevent the nest of tubes from being deformed or damaged, when assembling or disassembling the radiator unions and hoses, the radiator sleeves' must be kept rotating by means of a wrench. The outer surface of the nest of tubes must always be kept clean in order to enable proper heat transfer. In the event of a leak, the source of the leak must be detected. In order to do this:

-Stop the CPVS.

-Clean the greasy areas.

-Look for leaks using conventional means (soap solution, …).

Pressurized shutdown retains the pressure in the machine circuit for a few moments so that any leak can be more easily located.

E - Oil separator (see B Section 1)

The oil separator's lifespan depends on the cleanliness of the air coming into the compressor, on regular oil filter changes, on the qua- lity of the oil used, on the attention with which the oil tank condensate drains are carried out and on the ambient temperature of the room. (see notice on the electronic plate for resetting the time).

Check the cleanliness of the pipe that returns the oil to be aspired (transparent) to prevent the injector from becoming blocked and to ensure that the oil recovered can pass through easily.

Excessive oil consumption

The presence of excess oil in the discharge air, a rapid drop in level show a probable deterioration in the oil separator that must be changed.

The unit must first be checked to make sure that there is no oil loss and that the oil return is working properly.

Changing the oil separator

Dismantle all the piping connected to the tank's upper flange (air discharge, regulation system supply, and oil return). Undo the screws that hold the tank cover and remove it.

-If the old oil separator musty be remounted, use new seals.

-Be very careful during installation of the oil separator so as to avoid possible damage.

-The new oil separator is delivered with its two seals on either side of the flange.

-Slight undulations in the flange will flatten out when the screws are tightened.

-Apply a 6 mkg torque.

-Replace the oil return tube correctly so it touches the bottom of the oil separator.

F - Oil return pipe (see fig. 20)

Placed under the compressor

Dismantle the body of the anti-oil return pipe.

Lift the anti-oil return pipe.

Check the state of the o-ring (rep. 64).

Reassemble.

01/2008 Page 22

Fig. 20 - Oil return pipe

64

G - Draining condensation water

(see B Section 1)

Condensation water prevents proper lubrication. The resulting substantial wear leads to a reduction in the lifespan of the CPVS. It is therefore essential to drain condensation water.

Draining of condensates in the oil circuit (see fig. 19) :

Draining will only take place at least 12 hours after the CPVS has been shut down. It can be carried out for example on the morning of the start-up.

To do this :

-Slowly open the oil change tap and let the water escape.

-When the oil appears, close the valve immediately to avoid any loss.

-Refill with oil if necessary.

H - Temperature safety tests

(See instructions electronic board).

IF THE SENSOR IS NOT WORKING, IT MUST BE CHANGED.

I - Refastening electric connections

A loosening of the electric power cables leads to the contactors ove-rheating which can lead to their destruction.

Periodic refastening is therefore necessary at the star and triangle line contactor arrivals and departures. (see Maintenance Table).

All electric power supply to the machine must be cut off before opening the electric cabinet.

J - Decommissioning the compressor at the end of its useful life (see B Section 1)

1.Stop the compressor and close the air outlet valve.

2.Unplug the compressor from the electric supply.

3.Decompress the compressor : unplug the 4/6 piping on the oil separator cover.

4.Close and decompress the section of the air network which is linked to the exit valve. Disconnect from the compressed air exit pipe from the air network.

5.Empty the circuits of oil and condensates.

6.Disconnect the compressor condensate piping from the condensate draining system.

Chicago Pneumatic Compressors 62 305 258 65

Image 22
Contents Model Cpvs 40 50 60 CpvsPSI Mini + 36 F frost free Maxi + 104 FCpvs Model NPTAWG Main Voltage 460 Volt / 3 / 60 HzConnection of the electric plate to an external control box Contents Power Supply AIR DeliveryRespect of the environment and prevention of pollution DescriptionGeneral Information Standard equipmentDefinition of the pictograms Electronic boardInstallation Electric cabling Safety RegulationsVoltage Safety Discharge pressure adjustmentParallel compressor assembly Preparation for start-upKey fig OperationAir and oil circuits Air circuits see FigLevel detection bleed valve Fig OptionsAdvanced filtration to the compression air inlet a and 7b Support grid Pre-filtration panelsFilter Medium Automatic restarting Rotation direction indicator Phase controllerFeatures Remote starting and stoppingCentrifugal separator See B Section Description of the optionSafety Rules InstallationSafety instructions Description cf SectionPreparation for start-up See Section Setting of pressure machineCommissioning Control of rotation direction on start upPrinciple of the pressure regulation by variable speed Pressure regulation for low rates of flow Energy savingOperating incidents Main incidentsOperations to be carried out Parts MaintenanceObservations Turbine Oil level and change see figAir filter OillevelOil separator see B Section Temperature safety testsOil and air cooler Oil return pipe see figMain incidents See -ESupport@CPcompressor.com