A - Oil level and change (see fig. 19)

(see B Section 1)

The recommended oil used for the first compressor fill up is a mineral oil with the following properties :

-viscosity: 40 cSt at 104 °F

-viscosity index: 90 minimum

-antioxidant additives

-anti-rust additives

-anti-foam additives

THE FIRST OIL CHANGE MUST BE CARRIED OUT AFTER THE FIRST 500 HOURS OPERATION.

Using a synthetic oil for compressors is also acceptable and means less frequent oil changes: please speak to us about the compatibility and oil change methodes.

The oil change and the replacement of oil filter must be carried out when the indication is seen on the electronic controller and when the corresponding time counter reaches "0" (refer to electronic plate manual Section 1 E ).

Drain the compressor when warm. For this, shut it down taking care to disconnect the power cable. Release pressure in the tank by unscrewing the filler plug by a single turn. Open the purge valve and drain the oil. Do not forget to close the valve after draining the oil.

After maintenance, reset the time counter which tells you how long you have before the next oil change is due, refer to electronic plate manual Section 1 E.

OILLEVEL

When the machine is not running, the MAXIMUM oil level cor- responds to the top part of the green area, and the MINIMUM level is represented by the low part of this green area.

CHECKING THE OIL LEVEL MUST BE CARRIED OUT JUST AFTER STOPPING THE MACHINE (THERMOSTAT VALVE OPEN).

DRAINAGE UNDER PRESSURE

So as to carry out a quick and full oil change, your CPVS is equip- ped with a system that allows low level pressure to be maintained in the oil circuit. This pressure is shown by the pressure gauge situated in the tank. (see Notice AIRLOGIC - E Section 1).

Proceed as follows :

When hot, compressor in load for programming a shutdown under pressure (refer notice AIRLOGIC § 4.9.3). The machine is emptied and stops automatically.

Change the oil by opening the oil change valve very slowly.

When there is no pressure left in the oil tank, change the oil filter cartridge.

As soon as the oil is no longer flowing, close the valve and refill with new oil.

Reinitialise the timers that will warn you when to carry out the next oil change and the next oil filter change

(see the AIRLOGIC Manual - E Section 1),

Reseal the filler cap when replacing it and check that all openings are properly closed.

The machine can be restarted only after pressing the button C several times to return to STATE 0.1. Check the clamping of connections.

After restarting, check that there are no oil leaks.

Chicago Pneumatic Compressors 62 305 258 65

NOTE

If the oil is in a bad state ; that is a pungent smell or contains particles or varnish or other solid matter, the system will have to be rinsed : pour about 50% or the normal contents of clean oil and operate the unit for 3 hours and carefully change the oil. During rinsing, leave the old oil filter cartridge in the machine.

B - Air filter

(see B Section 1)

The air filter is of the dry, encapsulated type. Change the cartridge every 2,000 hours. Check the cleanliness of the filter every week and change it if necessary. (see notice on the electronic plate for resetting the time).

ATTENTION :

If you do not replace the filtering element when needed, per- manent dirt build-up will result. This reduces the air inflow to the compressor and could damage the oil separator and the compressor.

Fig. 19 - Oil level

Filler plug

Oil level

Drainage

C - Turbine

Replacement of the complete fan is recommended if one or more blades are deformed or broken If replaced, check the fan rotation direction reversal of the rotation direction will reduce machine cooling and damage the motor in time.

01/2008 Page 21

Image 21
Contents Cpvs Model Cpvs 40 50 60Cpvs Model Mini + 36 F frost free Maxi + 104 FPSI NPTMain Voltage 460 Volt / 3 / 60 Hz AWGConnection of the electric plate to an external control box Contents AIR Delivery Power SupplyGeneral Information DescriptionRespect of the environment and prevention of pollution Standard equipmentElectronic board Definition of the pictogramsInstallation Safety Regulations Electric cablingVoltage Parallel compressor assembly Discharge pressure adjustmentSafety Preparation for start-upAir and oil circuits OperationKey fig Air circuits see FigOptions Level detection bleed valve FigAdvanced filtration to the compression air inlet a and 7b Pre-filtration panels Support gridFilter Medium Features Rotation direction indicator Phase controllerAutomatic restarting Remote starting and stoppingDescription of the option Centrifugal separator See B SectionSafety instructions InstallationSafety Rules Description cf SectionCommissioning Setting of pressure machinePreparation for start-up See Section Control of rotation direction on start upPressure regulation for low rates of flow Energy saving Principle of the pressure regulation by variable speedMain incidents Operating incidentsMaintenance Operations to be carried out PartsObservations Air filter Oil level and change see figTurbine OillevelOil and air cooler Temperature safety testsOil separator see B Section Oil return pipe see figSee -E Main incidentsSupport@CPcompressor.com