Chicago Pneumatic CPVS 50 Automatic restarting, Remote starting and stopping, Operation, Features

Page 14

D -Automatic restarting

1 - Description

This management system enables the compressor to be restarted automatically after a power outage.

2 - Option overview

Not available in standard version in order to prevent any incident during maintenance operations carried out by an untrained person. This option is proposed in cases where the production of compressed air should suffer only the minimum periods of shutdowns.

The standard microcut time accepted by AIRLOGIC is approximately : 250 ms.

However, certain electrical fittings create longer micro cut-offs that will cause a compressor shut down, then a manual restart.

Automatic compressor restarting enables immediate air produc- tion after a power outage and thus avoids the time lapse required for manual compressor restarting that would mean a fall in pres- sure in the air circuit.

Particularly used for industries where air production should not be subject to shut downs that waste the products manufactured or damage the production equipment.

THISOPERATIONREQUIRESTHECONFIGURATION

OFMENUSINTHECONTROLLER,ACCESS

RESTRICTED TO TECHNICIANS CERTIFIED BY

CHICAGO PNEUMATIC COMPRESSORS.

AN INFORMATIVE INSERT MUST BE PLACED ON THE ELECTRIC CABINET TO WARN THE USER OF THE RISK THAT THE COMPRESSOR MAY AUTOMATICALLY RESTART AT ANY TIME.

3 - Technical features

This option requires configuration of the electronic plate and installation of an informative insert on the door of the compressor electric cabinet.

Every time the compressor stops, it must be secured by

opening and locking the electric section switch.

E - Remote starting and stopping

This option allows the compressor to be remotely started and stopped. However, in all cases, stopping the compressor at the machine itself is essential. If the compressor is shut down from a distance, it may be restarted from a distance as well. For any intervention to be conducted on the machine, it is essential to activate the emergency stop of the machine in order to ensure safe conditions (Refer to AIRLOGIC Manual, E Section 1)

F - Rotation direction indicator -

Phase controller

1 - Description

The phase controller option is designed to:

-control the rotation direction of the machine's electric power supply phases.

-check that electric power is supplied to each phase.

These two functions are permanently guaranteed.

2 - Option overview

The advantages of this option are:

-starting the machine with the guarantee that it will work (if this option was factory-installed), the configuration of the rotation direction having been configured during the production tests.

-protecting the motor and the electrical fittings from any loss of power supply (phase cuts, blown fuses, voltage threshold lower than 130 volts).

-protecting the machine (motor and especially the compression assembly) when restarting it following electrical work on the power supply line or when switching from the mains supply to a backup power supply, such as a power generator.

3 - Operation

In the event of a phase failure (detectable by this option) or an incorrect rotation direction, the trip switch sets off the machine's safety system (preventing immediate stopping and starting of the machine) and shows the following message on the display of the electronic plate: "ventilation flaw".

4 - Features

scanning time / measurement cycle

< 80 ms

minimum operating voltage

200 volts

maximum acceptable voltage between phases

600 volts

power consumption

15 VA

01/2008

Chicago Pneumatic Compressors

Page 14

62 305 258 65

Image 14
Contents Model Cpvs 40 50 60 CpvsPSI Mini + 36 F frost free Maxi + 104 FCpvs Model NPTConnection of the electric plate to an external control box Main Voltage 460 Volt / 3 / 60 HzAWG Contents Power Supply AIR DeliveryRespect of the environment and prevention of pollution DescriptionGeneral Information Standard equipmentDefinition of the pictograms Electronic boardInstallation Voltage Safety RegulationsElectric cabling Safety Discharge pressure adjustmentParallel compressor assembly Preparation for start-upKey fig OperationAir and oil circuits Air circuits see FigAdvanced filtration to the compression air inlet a and 7b OptionsLevel detection bleed valve Fig Filter Medium Pre-filtration panelsSupport grid Automatic restarting Rotation direction indicator Phase controllerFeatures Remote starting and stoppingCentrifugal separator See B Section Description of the optionSafety Rules InstallationSafety instructions Description cf SectionPreparation for start-up See Section Setting of pressure machineCommissioning Control of rotation direction on start upPrinciple of the pressure regulation by variable speed Pressure regulation for low rates of flow Energy savingOperating incidents Main incidentsObservations MaintenanceOperations to be carried out Parts Turbine Oil level and change see figAir filter OillevelOil separator see B Section Temperature safety testsOil and air cooler Oil return pipe see figMain incidents See -ESupport@CPcompressor.com