Operating Instructions AUTO RUN, COOL,HEAT and DRY operation

Recommendations

Use COOL in summer.

Use HEAT in winter.

Use DRY in spring,autumn and in damp climate.

 

 

MODE FAN

SWING

AUTO

2

TEMP

HEALTH

 

 

 

4

 

 

CLOCK3

SET

SET

 

TIMER

SLEEP

AM

 

FILTER RESET RESET

 

 

 

5

ON/OFF

1

T E M P

 

ON

 

OFF

 

SWING

FAN

5

 

MODE

SLEEP

HEALTH FRESH

 

CLOCK

SET

TIMER

 

RESET

LIGHT LOCK

(1) Unit start

Press ON/OFF button, unit starts.

Previous operation status appears on display (Not Timer setting). Power indicator lights up.

(2) Select operation mode

Press MODE button. For each press, operation mode changes as follows:

Press FAN button. For each press, fan speed changes as follows:

Wire controller

LOW MID HIGH

Remote controller

LOW MID HIGH

AUTO

AUTO

A

U

T

O

AUTO

AUTO COOL DRY HEAT FAN

Unit will run in operation mode displayed on LCD. Stop display at your desired mode.

(3) Select temp. setting

Press TEMP button

Every time the button is pressed, temp. setting increases 1 C.

If button is kept depressed, temp.setting will increase quickly.

Every time the button is pressed, temp. setting decreases 1C.

If button is kept depressed, temp. setting will decrease quickly.

Unit will start running to reach the temp. setting on LCD.

Unit runs at the speed displayed on LCD.In HEAT mode, warm air will blow out after a short period of time due to cold-draft prevention function.

In DRY mode, when room temp. becomes 2 C higher than temp. setting, unit will run intermittently at LOW speed regardless of FAN setting.

(5) Unit stop

Press ON/OFF button.

Only time and room temp remains on LCD. All indicators go out.

Vertical flap closes automatically.

Hints

Wire controller can memorize each operation status. When starting it next time, just press ON/OFF button and unit will run in previous status.

(4) Fan speed selection

Auto running: During the Auto running mode, air conditioning running and can auto-select the cooling, heating, fan mode according to the room temperature.

Fan running: The AC only have air supply running no cooling and heating running at the condition, AC can't have auto air supply running, and can't display the setting temperature value on the LCD.

During the heating running, after start the AC, in order to prevent cooled air, AC can stop for a while before send heat air.

During the dehumification running, when the room temp. setting temp. , not setting condition according to the air speed.

1 2

Image 13
Contents Ceilingconcealedtypeairconditionerindoorunit ContentsPage DB C AE072FCAKA AE242FCAKA Fig1 Calibration of clock Remote controller Operation of remote controller 20 1.ON/OFF button Clock set Important Points of Safety Smell etc. occurs, stop running Important Points of Safety Recommendations Operating Instructions Timer OperationTimer ON-OFF Sleep Function Health Function Following cases are not troubles Trouble ShootingSystem couldnt start Is power on/off switched on? Poor cooling or heating When Fault OccursPoor cooling Information about application Installation Precautions Electrical requirements Installing toolsFigure showing installation dimensions unitmm Installation ProcedureInstallation of indoor unit Transitive air duct New concrete slab Remove upper cover of wire controller Installation of remote controllerInstallation of receive display Requirements Drain pipeRefrigerant piping Pipe expansion dimensions as followsPipe cutting and expanding Open all valves Ring terminal connection method Electric wiringField setting Indoor unit malfunction display code MalfunctionOutdoor unit malfunction display code Outdoor unit malfunction Indoor unit malfunction