MRV Communications AE212FCAKA, AE09~212FCAKA, AE092FCAKA, AE072FCAKA, AE142FCAKA 20 1.ON/OFF button

Page 8

D

Remote LCD display contents and key name and each key function introduction

11

12

13

4

6

21

201.ON/OFF button

 

 

B

A

Used to turn on/off unit

 

 

2.Temperature Setting button

 

 

 

15

AUTO

ion

 

16

Used to set temperature,

 

 

 

17

temperature range: 16 C~30 C

 

 

OFF

18

3.Health

 

 

H

19

Used to control the

 

 

T E M P

2

generating oxygen function

 

 

ON

 

and negative ion-function

 

 

OFF

7

HEALTH

 

 

 

 

FAN

4.Operation mode button

MODE

SWING

 

 

8

Used to set working mode:

 

9

Cooling, Dehumidifying,

TIMER

Heating

 

 

5.Timer button

 

 

Used to set the

RESETCODE

LOCK

mode of timer

 

10

6.Reset button

 

 

When the remote controller appears abnormal condition, use a sharp-pointed article to press this button to make the wire controller resume normal

7.Fan speed button

Used to set fan speed

8.Swing button

Used to set Auto Swing or

Fixed air sending direction

9.Time Adjusting button 10.Lock button

Press on time lock all the key sand press another time concel the lock.

11.Working mode display

12.Fan speed display

Used to display the fan speed. After setting "AUTO" function,air speed can auto change according to the temp. difference between the room temp. and setting temp.

13.Health running display

Used to display healthy running.

14.Timer ON/OFF display

Display Timing mode. "Blank" No Timing

"OFF " Timing off

"ON " Timing on

15.Signal display

Sending out signal to the remote receiver.

16.Temperature display Display the setting temp. value.

17.Lock display

Display the key have been locked.

18.Super/Soft operation display 19.Timing time display

Display timing open time or timing close time

20.Signal launch head

Use to send signal to the indoor unit receive window.

21.Code

Select remote control receive code(H-MRV Remote cnotrol type use A code)

Make sure that the remote controller is used within 7 meters from receiver window of the wire controller and there are no obstructions in between.

The remote controller or wire controller should be handled with care.

When operating the remote controller in an area where electronically controlled lights are installed or wireless handsets are used, move closer to the indoor unit as the function of the remote controller might be affected by signals from this equipment.

 

R

Note:

 

1.After change the battery, working condition resume as follows:

 

Working mode:cooling

Temp. 26 C

Timming mode: normal

Air speed: Auto

2.The units used in this manual no 8 18 functions. The health key can only control the negative generator.

7

Image 8
Contents Contents CeilingconcealedtypeairconditionerindoorunitPage DB C AE072FCAKA AE242FCAKA Fig1 Calibration of clock Remote controller Operation of remote controller 20 1.ON/OFF button Clock set Important Points of Safety Smell etc. occurs, stop running Important Points of Safety Recommendations Timer Operation Operating InstructionsTimer ON-OFF Sleep Function Health Function Trouble Shooting Following cases are not troublesSystem couldnt start Is power on/off switched on? Poor cooling When Fault OccursPoor cooling or heating Information about application Installation Precautions Installing tools Electrical requirementsInstallation Procedure Figure showing installation dimensions unitmmInstallation of indoor unit Transitive air duct New concrete slab Installation of remote controller Remove upper cover of wire controllerInstallation of receive display Drain pipe RequirementsPipe cutting and expanding Pipe expansion dimensions as followsRefrigerant piping Open all valves Electric wiring Ring terminal connection methodField setting Outdoor unit malfunction display code MalfunctionIndoor unit malfunction display code Indoor unit malfunction Outdoor unit malfunction