MRV Communications AE242FCAKA, AE212FCAKA, AE09~212FCAKA, AE092FCAKA, AE072FCAKA Timer ON-OFF

Page 15

Operating Instructions

TIMER Operation

 

 

 

MODE FAN

 

SWING

 

 

 

TEMP

HEALTH

 

 

 

CLOCK

3

SET

 

 

 

 

 

SET

2

TIMER

 

SLEEP 6

 

 

 

 

 

AM

4

 

5

ON

OFF

 

FILTER RESET

RESET

 

 

 

 

PM

ON/OFF

1

 

T E M P

 

ON

SWING

OFF 1FAN

MODE

SLEEP

HEALTH FRESH3

CLOCK

SET

2

 

TIMER

6

 

TIMER ON-OFF

45

RESET

LIGHT LOCK

(1)After unit start, select your desired operation mode

Operation mode will be displayed on LCD. Power indicator lights up.

(2)Press TIMER button to change TIMER mode

Every time the button is pressed, display changes as follows:

ON

OFF

ON

blank

OFF

 

 

 

Select OFFON .

(3)Time setting for TIMER ON

Press TIME button.

Every time the button is pressed, time increases 10min. If button is kept depressed, time will change quickly.

Every time the button is pressed, time decreases 10min. If button is kept depressed, time will change quickly. Time will be shown on LCD.

It can be adjusted within 24hours.

AM refers to morning and PM to afternoon.

(4) Time confirming for TIMER ON

After time setting, press TIMER button to confirm. "ON" stops blinking, While "OFF" starts blinking.

Time displayed: Unit starts at Xhour X min.

(5)Time setting for TIMER OFF

Follow the same procedures in "Time setting for TIMER ON".

(6)Time confirming for TIMER OFF

After time setting, press SET button to confirm "OFF" stops flashing.

Time displayed: Unit stops at X hour X min.

To cancel TIMER mode

Just press TIMER button several times until TIMER mode disappears.

According to the Time setting sequence of TIMER ON or TIMER OFF, either Start-Stop or Stop-Start can be achieved.

1 4

Image 15
Contents Ceilingconcealedtypeairconditionerindoorunit ContentsPage DB C AE072FCAKA AE242FCAKA Fig1 Calibration of clock Remote controller Operation of remote controller 20 1.ON/OFF button Clock set Important Points of Safety Smell etc. occurs, stop running Important Points of Safety Recommendations Operating Instructions Timer OperationTimer ON-OFF Sleep Function Health Function Following cases are not troubles Trouble ShootingSystem couldnt start Is power on/off switched on? When Fault Occurs Poor cooling or heatingPoor cooling Information about application Installation Precautions Electrical requirements Installing toolsFigure showing installation dimensions unitmm Installation ProcedureInstallation of indoor unit Transitive air duct New concrete slab Remove upper cover of wire controller Installation of remote controllerInstallation of receive display Requirements Drain pipePipe expansion dimensions as follows Refrigerant pipingPipe cutting and expanding Open all valves Ring terminal connection method Electric wiringField setting Malfunction Indoor unit malfunction display codeOutdoor unit malfunction display code Outdoor unit malfunction Indoor unit malfunction