MRV Communications AE212FCAKA, AE09~212FCAKA, AE092FCAKA, AE072FCAKA Installation Procedure

Page 24

Installation Procedure

After selecting the unit installation location, proceed the following steps:

1.Drill a hole in the wall and insert the connecting pipe and wire through a PVC wall-through tube purchased locally. The wall hole shall be with a outward down slope of at least 1/100. (See Figure 2)

2.Before drilling check that there is no pipe or reinforcing bar just behind the drilling position. Drilling shall avoid at positions with electric wire or pipe.

3.Mount the unit on a strong and horizontal building roof. If the base is not firm, it will cause noise, vibration or leakage (see Figure 6).

4.Support the unit firmly.

5.Change the form of the connection pipe, connection wire and drain pipe so that they can go through the wall hole easily.

Figure showing installation dimensions: (unit:mm)

Model

a

b

c

d

e

f

g

i

AE092FCAKA

615

648

452

225

55

125

225

100

AE142FCAKAAE122FCAKA

770

804

452

225

55

125

225

100

AE212FCAKAAE182FCAKA

 

 

 

 

 

 

 

Fig 2

990

1024

452

225

55

125

225

100

 

 

 

 

 

 

c

 

 

 

 

 

b

 

 

 

 

i

 

 

 

 

 

 

 

 

e

f

g

 

d

 

 

 

500

a

223

223

1249

AE072FCAKA

AE242FCAKA

Notes

1.For electrical heating unit, the air outlet not allowed directly connecting with canvas etc. easy catching fire goods.

2.This series' indoor unit are all middle static pressure(30 Pa external static pressure ). 3.An access port must be provided during installation of indoor unit for maintenance.

23

Image 24
Contents Contents CeilingconcealedtypeairconditionerindoorunitPage DB C AE072FCAKA AE242FCAKA Fig1 Calibration of clock Remote controller Operation of remote controller 20 1.ON/OFF button Clock set Important Points of Safety Smell etc. occurs, stop running Important Points of Safety Recommendations Timer Operation Operating InstructionsTimer ON-OFF Sleep Function Health Function Trouble Shooting Following cases are not troublesSystem couldnt start Is power on/off switched on? When Fault Occurs Poor cooling or heatingPoor cooling Information about application Installation Precautions Installing tools Electrical requirementsInstallation Procedure Figure showing installation dimensions unitmmInstallation of indoor unit Transitive air duct New concrete slab Installation of remote controller Remove upper cover of wire controllerInstallation of receive display Drain pipe RequirementsPipe expansion dimensions as follows Refrigerant pipingPipe cutting and expanding Open all valves Electric wiring Ring terminal connection methodField setting Malfunction Indoor unit malfunction display codeOutdoor unit malfunction display code Indoor unit malfunction Outdoor unit malfunction