Note: Before using this function, must adjust the clock, or the sleep function will be disordered.

Comfortable Sleep

At night, before going to bed you can press down the SLEEP button on the controller and the air- conditioner will run by the comfortable sleeping mode to make you sleep more comfortable.

 

 

MODE

FAN

SWING

 

 

TEMP

HEALTH

 

 

CLOCK

 

SET

 

SET

TIMER

 

SLEEP

 

 

 

 

OFF

 

FILTER RESET RESET

AM

 

AM

 

 

ON/OFF

T E M P

ON

OFF

SWINGFAN

MODE SLEEP

HEALTH FRESH

CLOCKSET

TIMER

RESET

LIGHT LOCK

In cooling, dehumidifying mode

One hour after sleeping operation start, the temp. is 1 C higher than the setting one. After another hour the temp. rises 1C and then run continuously for another 6hrs' and then close. The actual temp. is higher than the setting one which is to prevent from being too cool to your sleep.

In heating mode

One hour after start up, the temp. decrease 2 C lower than the setting one. After another hour decrease by more 2 C.

The temperature will automatically rise by 1 C after another 3hrs' operation, and then automatically close after 3hrs' continuous operation. The actral temperature is lower than the setting one which is to prevent from being too hot to your sleep.

Note:

In AUTO mode, unit will run in SLEEP function according to the operation mode.

After setting SLEEP function, it is forbidden to calibrate clock.

If the set sleep-time does not reach 8 hours, the unit will stop operation automatically after set time is complete.

Set "TIMER-OFF" function first, then set SLEEP, and the sleep-set is performance; set TIMER- ON function first, the sleep function can only be set before TIMER-ON; if set theSLEEP function first, the TIMER function can not be set.

After setting sleep function, not allowed to adjust the clock. Can't use the remote controller operate the AC. If so, please cancel the sleep function first.

After setting sleep function, can't set the timing function.

SETTING T

 

SHUT DOWN

1 hr

decrease 2 C

 

 

 

 

1 hr

 

 

decreases 2 C

 

 

about 3 hrs

 

3 hrs

increase1 C

SLEEP RUN BEGINS

SLEEP RUN STOPS

Heat mode

SLEEP RUN BEGINS

SLEEP RUN STOPS

 

 

about 6 hrs

 

1 hr

increase 1 C

1 hr

increase 1 C

 

 

SETTING T

 

SHUT DOWN

Cooling mode

1 5

Image 16
Contents Contents CeilingconcealedtypeairconditionerindoorunitPage DB C AE072FCAKA AE242FCAKA Fig1 Calibration of clock Remote controller Operation of remote controller 20 1.ON/OFF button Clock set Important Points of Safety Smell etc. occurs, stop running Important Points of Safety Recommendations Timer Operation Operating InstructionsTimer ON-OFF Sleep Function Health Function Trouble Shooting Following cases are not troublesSystem couldnt start Is power on/off switched on? Poor cooling or heating When Fault OccursPoor cooling Information about application Installation Precautions Installing tools Electrical requirementsInstallation Procedure Figure showing installation dimensions unitmmInstallation of indoor unit Transitive air duct New concrete slab Installation of remote controller Remove upper cover of wire controllerInstallation of receive display Drain pipe RequirementsRefrigerant piping Pipe expansion dimensions as followsPipe cutting and expanding Open all valves Electric wiring Ring terminal connection methodField setting Indoor unit malfunction display code MalfunctionOutdoor unit malfunction display code Indoor unit malfunction Outdoor unit malfunction