MRV Communications AE122FCAKA, AE212FCAKA, AE09~212FCAKA, AE092FCAKA Calibration of clock

Page 6

D

 

 

 

 

 

 

 

 

 

13

14

15 16

17

18

19

 

22.Setting button

 

 

 

 

 

 

 

12

 

 

 

 

 

 

 

 

Used to confirm

11

 

 

 

 

 

 

 

 

the time of timer

10

 

 

 

MODE

FAN

SWING

20

 

and clock

9

AUTO

 

 

TEMP

HEALTH

29

23.Sleep button

8

 

 

 

 

 

 

21

 

Used to set Sleep

7

 

 

 

CLOCK

 

SET

 

6

 

 

 

 

 

 

22

 

state

SET

 

 

TIMER

 

SLEEP

23

 

5

SUR

 

 

 

 

 

24.Time Adjusting

 

 

 

 

 

24

4

 

 

 

FILTER RESETRESET

 

button

 

 

 

 

 

 

25

 

3

 

 

 

 

 

 

26

 

Used to adjust the

 

 

 

ON/OFF

 

27

 

time of timer and

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

 

 

 

 

 

28

 

clock

1

 

 

 

 

 

 

 

 

13.Sleep state display

30

 

25.Reset button

1.ON/OFF button

 

 

 

 

 

 

When the wire

Used to turn on/off unit

 

14.Network control display

 

2.Temperature display

 

15.Working mode display

 

 

controller appears

3.Clock display

 

Working

Auto

 

Cooling Dehumidifying

Heating Fan

 

abnormal condition,

4.Timer ON/OFF display

mode

operation operation operation

operation operation

use a sharp-pointed

Wire

 

 

 

 

 

article to press this

5.Humidity display

 

controller

 

 

 

 

 

 

 

 

 

 

 

 

 

button to make the

6.Air filter cleaning display

16.Electric heating display

 

 

 

 

wire controller

When there is too much dust

 

17.Operation mode button

 

 

resume normal

collected on the air inlet, the

 

Used to set working mode:

 

26.Air Filter Reset

wire controller will show

 

 

 

 

 

Auto, Cooling, Dehumidifying,

 

button

this display to remind the

 

 

 

user to clean the air inlet.

 

 

Heating, Fan

 

 

After cleaning the

After cleaning and installation,

 

18.Fan speed button

 

 

air inlet, press this

just press the air filter reset button.

 

Used to set fan speed: Low

 

button, the unit

7.Super/Soft operation display

 

 

 

Fan, Med Fan, High Fan, Auto

 

can start to operate

8.Fan speed display

 

 

19.Swing button

 

27.Timer button

Auto

 

Used to set Auto Swing or

 

 

 

 

Used to set the

 

 

 

Fixed air sending direction

 

Low Fan Med Fan High Fan Auto

 

 

 

mode of timer

 

20.Temperature Setting button

 

9.Auto Swing display

 

28.Lock state display

 

 

Used to set temperature,

10.Health state display

 

 

29.Health

 

 

temperature range: 16 C~30 C

 

 

 

Used to control the

11.Fresh air state display

 

21.Clock button

 

 

 

 

 

generating oxygen

12.Humidifying state display

 

Used to calibrate the time of

 

 

 

function and negative

 

 

 

timer and clock

 

 

ion-function

Note:

1.This model does not have the following related display and function 5 6 7 9 11 12 14 16 26

2.The outdoor unit no oxygen-bar function or no negative ion

unit no 10 19 healthl function display.

30.Remote control window

Used to receive the remote control signal

Calibration of clock

When turning on the unit for the first time, the clock should be calibrated. The method of calibration is:

1.Press ìClockî button, the Clock display ìAMî ìPMî will flash.

2.Press or to adjust time. For each press, the time will increase or decrease 1 *minute. If depressing the button, the time will increase or decrease rapidly. 3.After confirming the time, press ìSetî button, ìAMî or ìPMî will stop flashing,the

clock will begin to work.

5

Image 6
Contents Contents CeilingconcealedtypeairconditionerindoorunitPage DB C AE072FCAKA AE242FCAKA Fig1 Calibration of clock Remote controller Operation of remote controller 20 1.ON/OFF button Clock set Important Points of Safety Smell etc. occurs, stop running Important Points of Safety Recommendations Timer Operation Operating InstructionsTimer ON-OFF Sleep Function Health Function Trouble Shooting Following cases are not troublesSystem couldnt start Is power on/off switched on? When Fault Occurs Poor cooling or heatingPoor cooling Information about application Installation Precautions Installing tools Electrical requirementsInstallation Procedure Figure showing installation dimensions unitmmInstallation of indoor unit Transitive air duct New concrete slab Installation of remote controller Remove upper cover of wire controllerInstallation of receive display Drain pipe RequirementsPipe expansion dimensions as follows Refrigerant pipingPipe cutting and expanding Open all valves Electric wiring Ring terminal connection methodField setting Malfunction Indoor unit malfunction display codeOutdoor unit malfunction display code Indoor unit malfunction Outdoor unit malfunction