Connecting the Storage Array
The storage array is connected to a host using two
For more information, see the Getting Started Guide.
Each RAID controller module has four SAS In port connectors that provide SAS connections to the host or node. Each RAID controller module also contains an Ethernet management port and a SAS Out port connector. The Ethernet management port allows you to install a dedicated management station (server or
Each Dell PowerVault MD3200 series storage array can be expanded to a maximum of 120 (or 192, if enabled through the Premium Feature activation) physical disks through a maximum of seven PowerVault MD1200 series expansion enclosures.
NOTE: When you connect a host server to a storage array SAS In port connector, any Out port connector of the server's host bus adapter (HBA) can be used.
Cabling the Storage Array
You can cable the storage array to host servers with:
•Single path data
•Dual path data
Choose the data configuration based on:
•Number of hosts required
•Level of data redundancy required
12
Hardware Installation