Dell MD3200, MD3220 manual Connecting the Storage Array, Cabling the Storage Array

Page 12

Connecting the Storage Array

The storage array is connected to a host using two hot-swappable RAID controller modules. The RAID controller modules are identified as RAID controller module 0 and RAID controller module 1.

For more information, see the Getting Started Guide.

Each RAID controller module has four SAS In port connectors that provide SAS connections to the host or node. Each RAID controller module also contains an Ethernet management port and a SAS Out port connector. The Ethernet management port allows you to install a dedicated management station (server or stand-alone system). The SAS Out port allows you to connect the storage array to optional expansion enclosures for additional storage capacity. For more information, see the Getting Started Guide.

Each Dell PowerVault MD3200 series storage array can be expanded to a maximum of 120 (or 192, if enabled through the Premium Feature activation) physical disks through a maximum of seven PowerVault MD1200 series expansion enclosures.

NOTE: When you connect a host server to a storage array SAS In port connector, any Out port connector of the server's host bus adapter (HBA) can be used.

Cabling the Storage Array

You can cable the storage array to host servers with:

Single path data configuration—A single path configuration allows you to connect a maximum of eight hosts. This is a non-redundant configuration.

Dual path data configuration—A dual path configuration allows you to connect a maximum of four hosts.

Choose the data configuration based on:

Number of hosts required

Level of data redundancy required

12

Hardware Installation

Image 12
Contents Deployment Guide Dell Inc Contents ISCSI Configuration Worksheet Configuring iSCSI on Your Storage ArrayLocating Your System Service Tag Windows Load Balance PolicyDiscover the Storage Array Out-of-band Management Only Configure the iSCSI Ports on Configure Host Access Understanding Chap AuthenticationConfigure Chap Authentication on Configuring Target Chap Authentication onIntroduction System RequirementsManagement Station Requirements Introduction to Storage Arrays Introduction Introduction Hardware Installation Planning the Storage ConfigurationConnecting the Storage Array Cabling the Storage ArrayRedundant and Non-Redundant Configurations Single Controller ConfigurationsTwo Hosts Connected to a Single Controller Four Hosts Connected to a Single Controller Dual Controller Configurations Two Hosts Connected to Two ControllersFour Hosts Connected to Two Controllers Four Hosts Connected to Two Controllers Eight Hosts Connected to Two Controllers Four Cluster Nodes Connected to Two Controllers Four Cluster Nodes Connected to Two Controllers Cabling PowerVault MD1200 Series Expansion Enclosures Hardware Installation Hardware Installation Click Advanced→ Maintanence→ Download→ EMM Firmware Hardware Installation Installing PowerVault MD Storage Software Graphical Installation Recommended Select Install MD Storage SoftwareConsole Installation Silent InstallationUpgrading PowerVault MD Storage Software Post Installation Tasks Standard Terminology Used in iSCSI Configuration DefinitionBefore You Begin ISCSI Configuration Worksheet IPv4 Settings-Worksheet SecretIPv6 Settings-Worksheet Mutual Chap Target ChapConfiguring iSCSI on Your Storage Array Host Server Vs. Storage Array ManagerStorage Array Configuration Before Starting the Configuration Process Configure the Storage Array Using Mdcu Post Connection Establishment StepsGuidelines For Configuring Your Network For iSCSI Microsoft Windows Host SetupUsing a Dhcp server Using static IP addressingUsing a DNS server Using a Wins ServerLinux Host Setup Using DhcpUsing a Static IP Address HWADDR=XXXXXXXXXXXX GATEWAY=192.168.1.1 Post Installation Tasks Uninstalling PowerVault MD Storage Software Uninstalling MD Storage Software From WindowsUninstalling MD Storage Software From Linux Run the file Uninstall Dell MD Storage Software.exeLocating Your System Service Tag Getting HelpContacting Dell Documentation Feedback Appendix-Load Balancing Windows Load Balance PolicyRound Robin With Subset Least Queue Depth With Subset Changing Load Balance Policies in Windows SeverSetting Load Balance Policies in Linux Appendix-Load Balancing Appendix-Manual Configuration of iSCSI Array Using MD Storage ManagerTable B-1. Host Server Vs. Storage Array Default Management IPv4 Port Settings Default Management IPv6 Port SettingsDiscover the Storage Array Out-of-band Management Only Automatic Storage Array Discovery Setting Up the Array Manual Storage Array DiscoveryConfigure the iSCSI Ports on the Storage Array Table B-2. Initial Setup Tasks Dialog Box PurposeAppendix-Manual Configuration of iSCSI Perform Target Discovery From the iSCSI Initiator Set the iSCSI initiator service to start automatically Configure Host Access Understanding Chap Authentication What is CHAP?Target Chap Mutual ChapConfigure Chap Authentication on the Storage Array Optional Configuring Target Chap Authentication on the Storage ArrayChap Definitions Table B-3. Chap Types Defined DescriptionConfiguring Mutual Chap Authentication on the Storage Array Table B-4. Chap Setting Option DescriptionConfigure Chap Authentication on the Host Server Optional Add the target portal with Chap defined Discovery.sendtargets.auth.authmethod = Chap Appendix-Manual Configuration of iSCSI Connect to the Target Storage Array From the Host Server Local Adapter-Must be set to Microsoft iSCSI InitiatorIf you are using Windows Server 2008 Core Version TCPPortNumberOfTargetPortal is Optional Set Up In-Band Management Appendix-Manual Configuration of iSCSI Appendix-Manual Configuration of iSCSI