Dell MD3220, MD3200 manual Introduction, System Requirements, Management Station Requirements

Page 7

1

Introduction

This guide provides information about deploying Dell PowerVault MD3200 and Dell PowerVault MD3220 storage arrays. The deployment process includes:

Hardware installation

Modular Disk Storage Manager (MDSM) software installation

Initial system configuration

Other information includes system requirements, storage array organization, and utilities.

NOTE: For more information on product documentation, see dell.com/support/manuals.

MDSM enables an administrator to configure and monitor storage arrays for optimum usability. The version of MDSM included on the PowerVault MD series resource media can be used to manage both the PowerVault MD3200 series and the earlier PowerVault MD series storage arrays. MDSM is compatible with both Microsoft Windows and Linux operating systems.

System Requirements

Before installing and configuring the PowerVault MD3200 series hardware and software, ensure that a supported operating system is installed and the minimum system requirements are met. For more information, see the Support Matrix at dell.com/support/manuals.

Management Station Requirements

A management station uses MDSM to configure and manage storage arrays across the network. A management station must meet the following minimum system requirements:

Intel Pentium or an equivalent processor (1333 MHz or faster) with 512 MB RAM (1024 MB recommended).

1 GB disk space.

Introduction

7

Image 7
Contents Deployment Guide Dell Inc Contents Configuring iSCSI on Your Storage Array ISCSI Configuration WorksheetWindows Load Balance Policy Locating Your System Service TagDiscover the Storage Array Out-of-band Management Only Configuring Target Chap Authentication on Configure the iSCSI Ports onConfigure Host Access Understanding Chap Authentication Configure Chap Authentication onSystem Requirements IntroductionManagement Station Requirements Introduction to Storage Arrays Introduction Introduction Planning the Storage Configuration Hardware InstallationCabling the Storage Array Connecting the Storage ArraySingle Controller Configurations Redundant and Non-Redundant ConfigurationsTwo Hosts Connected to a Single Controller Four Hosts Connected to a Single Controller Two Hosts Connected to Two Controllers Dual Controller ConfigurationsFour Hosts Connected to Two Controllers Four Hosts Connected to Two Controllers Eight Hosts Connected to Two Controllers Four Cluster Nodes Connected to Two Controllers Four Cluster Nodes Connected to Two Controllers Cabling PowerVault MD1200 Series Expansion Enclosures Hardware Installation Hardware Installation Click Advanced→ Maintanence→ Download→ EMM Firmware Hardware Installation Installing PowerVault MD Storage Software Select Install MD Storage Software Graphical Installation RecommendedSilent Installation Console InstallationUpgrading PowerVault MD Storage Software Standard Terminology Used in iSCSI Configuration Definition Post Installation TasksBefore You Begin ISCSI Configuration Worksheet Secret IPv4 Settings-WorksheetMutual Chap Target Chap IPv6 Settings-WorksheetConfiguring iSCSI on Your Storage Array Manager Host Server Vs. Storage ArrayStorage Array Configuration Before Starting the Configuration Process Post Connection Establishment Steps Configure the Storage Array Using MdcuUsing static IP addressing Guidelines For Configuring Your Network For iSCSIMicrosoft Windows Host Setup Using a Dhcp serverUsing a Wins Server Using a DNS serverUsing Dhcp Linux Host SetupUsing a Static IP Address HWADDR=XXXXXXXXXXXX GATEWAY=192.168.1.1 Post Installation Tasks Uninstalling MD Storage Software From Windows Uninstalling PowerVault MD Storage SoftwareRun the file Uninstall Dell MD Storage Software.exe Uninstalling MD Storage Software From LinuxGetting Help Locating Your System Service TagContacting Dell Documentation Feedback Windows Load Balance Policy Appendix-Load BalancingRound Robin With Subset Changing Load Balance Policies in Windows Sever Least Queue Depth With SubsetSetting Load Balance Policies in Linux Appendix-Load Balancing Array Using MD Storage Manager Appendix-Manual Configuration of iSCSITable B-1. Host Server Vs. Storage Array Default Management IPv6 Port Settings Default Management IPv4 Port SettingsDiscover the Storage Array Out-of-band Management Only Automatic Storage Array Discovery Manual Storage Array Discovery Setting Up the ArrayTable B-2. Initial Setup Tasks Dialog Box Purpose Configure the iSCSI Ports on the Storage ArrayAppendix-Manual Configuration of iSCSI Perform Target Discovery From the iSCSI Initiator Set the iSCSI initiator service to start automatically Configure Host Access Mutual Chap Understanding Chap AuthenticationWhat is CHAP? Target ChapTable B-3. Chap Types Defined Description Configure Chap Authentication on the Storage Array OptionalConfiguring Target Chap Authentication on the Storage Array Chap DefinitionsTable B-4. Chap Setting Option Description Configuring Mutual Chap Authentication on the Storage ArrayConfigure Chap Authentication on the Host Server Optional Add the target portal with Chap defined Discovery.sendtargets.auth.authmethod = Chap Appendix-Manual Configuration of iSCSI Local Adapter-Must be set to Microsoft iSCSI Initiator Connect to the Target Storage Array From the Host ServerIf you are using Windows Server 2008 Core Version TCPPortNumberOfTargetPortal is Optional Set Up In-Band Management Appendix-Manual Configuration of iSCSI Appendix-Manual Configuration of iSCSI
Related manuals
Manual 260 pages 11.3 Kb Manual 272 pages 61.39 Kb Manual 22 pages 36.51 Kb