Dell MD3220, MD3200 manual Configuring iSCSI on Your Storage Array

Page 35

iSCSI controller 1, In 0 IP address Routable IP address 1 Routable IP address 2 Router IP address

iSCSI controller 1, In 1 IP address Routable IP address 1 Routable IP address 2 Router IP address

FE80

: 0000

: 0000

: 0000

: ____ : ____ : ____ : ____

____

: ____

: ____

: ____

: ____ : ____ : ____ : ____

____

: ____

: ____

: ____

: ____ : ____ : ____ : ____

____

: ____

: ____

: ____

: ____ : ____ : ____ : ____

FE80

: 0000

: 0000

: 0000

: ____ : ____ : ____ : ____

____

: ____

: ____

: ____

: ____ : ____ : ____ : ____

____

: ____

: ____

: ____

: ____ : ____ : ____ : ____

____

: ____

: ____

: ____

: ____ : ____ : ____ : ____

Configuring iSCSI on Your Storage Array

The following sections contain step-by-step instructions for configuring iSCSI on your storage array. However, before you begin, it is important to understand where each of these steps occur in relation to your host server or storage array environment.

The following table shows each iSCSI configuration step and where it occurs.

Post Installation Tasks

35

Image 35
Contents Deployment Guide Dell Inc Contents Configuring iSCSI on Your Storage Array ISCSI Configuration WorksheetDiscover the Storage Array Out-of-band Management Only Locating Your System Service TagWindows Load Balance Policy Configuring Target Chap Authentication on Configure the iSCSI Ports onConfigure Host Access Understanding Chap Authentication Configure Chap Authentication onManagement Station Requirements IntroductionSystem Requirements Introduction to Storage Arrays Introduction Introduction Planning the Storage Configuration Hardware InstallationCabling the Storage Array Connecting the Storage ArraySingle Controller Configurations Redundant and Non-Redundant ConfigurationsTwo Hosts Connected to a Single Controller Four Hosts Connected to a Single Controller Two Hosts Connected to Two Controllers Dual Controller ConfigurationsFour Hosts Connected to Two Controllers Four Hosts Connected to Two Controllers Eight Hosts Connected to Two Controllers Four Cluster Nodes Connected to Two Controllers Four Cluster Nodes Connected to Two Controllers Cabling PowerVault MD1200 Series Expansion Enclosures Hardware Installation Hardware Installation Click Advanced→ Maintanence→ Download→ EMM Firmware Hardware Installation Installing PowerVault MD Storage Software Select Install MD Storage Software Graphical Installation RecommendedSilent Installation Console InstallationUpgrading PowerVault MD Storage Software Before You Begin Post Installation TasksStandard Terminology Used in iSCSI Configuration Definition ISCSI Configuration Worksheet Secret IPv4 Settings-WorksheetMutual Chap Target Chap IPv6 Settings-WorksheetConfiguring iSCSI on Your Storage Array Manager Host Server Vs. Storage ArrayStorage Array Configuration Before Starting the Configuration Process Post Connection Establishment Steps Configure the Storage Array Using MdcuUsing static IP addressing Guidelines For Configuring Your Network For iSCSIMicrosoft Windows Host Setup Using a Dhcp serverUsing a Wins Server Using a DNS serverUsing a Static IP Address Linux Host SetupUsing Dhcp HWADDR=XXXXXXXXXXXX GATEWAY=192.168.1.1 Post Installation Tasks Uninstalling MD Storage Software From Windows Uninstalling PowerVault MD Storage SoftwareRun the file Uninstall Dell MD Storage Software.exe Uninstalling MD Storage Software From LinuxContacting Dell Locating Your System Service TagGetting Help Documentation Feedback Round Robin With Subset Appendix-Load BalancingWindows Load Balance Policy Changing Load Balance Policies in Windows Sever Least Queue Depth With SubsetSetting Load Balance Policies in Linux Appendix-Load Balancing Table B-1. Host Server Vs. Storage Array Appendix-Manual Configuration of iSCSIArray Using MD Storage Manager Discover the Storage Array Out-of-band Management Only Default Management IPv4 Port SettingsDefault Management IPv6 Port Settings Automatic Storage Array Discovery Manual Storage Array Discovery Setting Up the ArrayTable B-2. Initial Setup Tasks Dialog Box Purpose Configure the iSCSI Ports on the Storage ArrayAppendix-Manual Configuration of iSCSI Perform Target Discovery From the iSCSI Initiator Set the iSCSI initiator service to start automatically Configure Host Access Mutual Chap Understanding Chap AuthenticationWhat is CHAP? Target ChapTable B-3. Chap Types Defined Description Configure Chap Authentication on the Storage Array OptionalConfiguring Target Chap Authentication on the Storage Array Chap DefinitionsTable B-4. Chap Setting Option Description Configuring Mutual Chap Authentication on the Storage ArrayConfigure Chap Authentication on the Host Server Optional Add the target portal with Chap defined Discovery.sendtargets.auth.authmethod = Chap Appendix-Manual Configuration of iSCSI Local Adapter-Must be set to Microsoft iSCSI Initiator Connect to the Target Storage Array From the Host ServerIf you are using Windows Server 2008 Core Version TCPPortNumberOfTargetPortal is Optional Set Up In-Band Management Appendix-Manual Configuration of iSCSI Appendix-Manual Configuration of iSCSI
Related manuals
Manual 260 pages 11.3 Kb Manual 272 pages 61.39 Kb Manual 22 pages 36.51 Kb