Grizzly G0689 owner manual Circuit Requirements, 110V Operation

Page 11

SECTION 2: CIRCUIT REQUIREMENTS

110V Operation

Serious personal injury could occur if you connect the machine to power before com- pleting the setup process. DO NOT connect the machine to the power until instructed later in this manual.

Electrocution or fire could result if machine is not grounded and installed in compliance with electrical codes. Compliance MUST be verified by a qualified electrician!

Full Load Amperage Draw

Motor Draw

15 Amps

Circuit Requirements

You MUST connect your machine to a grounded circuit that is rated for the amperage given below. Never replace a circuit breaker on an existing cir- cuit with one of higher amperage without consult- ing a qualified electrician to ensure compliance with wiring codes. If you are unsure about the wiring codes in your area or you plan to con- nect your machine to a shared circuit, consult a qualified electrician.

Recommended Circuit Size

20 Amps

G0689 13" Planer

Power Connection Device

The Model G0689 comes with a 5-15 plug, similar to Figure 2, to connect the machine to power.

<gdjcY^c\Egdc\^h Adc\Zhid[i]ZI]gZZ Egdc\h

8jggZci 8Vggn^c\Egdc\h <gdjcYZY

DjiaZi

Figure 2. Typical 5-15 plug and receptacle.

This machine MUST have a ground prong in the plug to help ensure that it is grounded. DO NOT remove ­ground prong from plug to fit into a two-pronged outlet! If the plug will not fit the outlet, have the proper outlet installed by a qualified electrician.

Extension Cords

We do not recommend using extension cords, but if you find it absolutely necessary:

Use at least a 14 gauge cord that does not exceed 50 feet in length!

The extension cord must have a ground wire and plug pin.

A qualified electrician MUST size cords over 50 feet long to prevent motor damage.

-9-

Image 11
Contents Model G0689 Planer with BUILT-IN Dust Collection Ss ,EAD from Leadbased PAINTS Table of Contents Contact Info IntroductionManual Accuracy Functional Overview Identification G0689 13 Planer Machine Data SheetModel G0689  !,7!93 53%3 %!2.2 02/4%#4/ %. /0%2!4.! -!#.%29  !,7!93 53% !.3 !002/6%$$ 3!&%49 ,!33%33 7%. /0%2!4 !,7!93 ,/#+ -/,% !3%3 & 53%$ % %&/2% /0%2!4. -!#.%29#  53%3!!2/5.$%$ %84%.3/..#/2$ 2!4%$4&/2/4%-!#.%!-0%2!%2 53%3 2%#/--%.$%$- !##%33/2%3  -!.9 -!#.%3 #!. %*%#4 7/2+0%#%3 4/7!2$ /0%2!4/2Unplugging during adjustments Additional Safety Instructions for Planers110V Operation Circuit RequirementsUnpacking SetupSetup Safety InventoryWorkbench Load Clean UpPlacement Location Site ConsiderationsTo test run the machine Assembly Test RunTo attach the elevation crank assembly Mounting Example of a direct mount setup G0689 13 PlanerOperations Operation Safety Basic ControlsReset Button ON/OFF SwitchElevation Crank Depth-of-CutTo use the thickness stop Elevation LockThickness Stop Cutterhead Elevation ScaleStep Basic OperationsPlaning Tips To use the planerWood Characteristics Type Wood TypesG7313-700 lb Capacity Shop FOX Stand AccessoriesT20803-13 Replacement Knives T20448T20452 T20501 T20456 H0736G8983 G8985 G8984 G8983-Tilting Roller StandG8984-Single Roller Stand G8985-5 Roller StandLubrication MaintenanceCleaning ScheduleTroubleshooting ServiceTo remove the knives Knife ReplacementTools Needed Qty To inspect the cutterhead, gib, and knives Motor To install the knivesTo replace the belt Drive BeltPerform Steps 2-3 from Drive Belt on To clean the feed rollersImpeller Belt Feed RollersExtension Wing/ Table Alignment Elevation Lock AdjustmentIf adjustment is necessary, proceed as fol- lows To adjust the elevation lockThickness Stop Calibration To adjust the thickness stopSwitch wiring G0689 13 Planer Wiring DiagramMain Parts Breakdown PartsDescription Main Parts ListGear Large 70T Base Parts Breakdown Base Parts List 302 301 303 304 307 305 306 308 309 22!.49 #!2$ 99.$5342!, .# 0//88 %,,.!- 7!  Warranty and Returns #ALL 4ODAYD&ORO! &2%%