Grizzly G0601 owner manual Extension Cords 220V Only, 50 ft

Page 17

For Model G0601 220V operation: The rec- ommended plug specified for the Model G0601 under Circuit Requirements has a grounding prong that must be connected to the equipment- grounding wire of the power cord. The plug must only be inserted into a matching receptacle (outlet) that is properly installed and grounded in accordance with all local codes and ordinances (see Figure 3).

GROUNDED

15-15 RECEPTACLE

15-15 PLUG

Current

Carrying

Grounding Prong Prongs

Figure 3. Typical 15-15 plug and receptacle.

For Model G0601 440V operation: As speci- fied in Circuit Requirements, the Model G0601 must be hardwired to the power source for 440V operation, and the power source must use a locking switch as a means of disconnection (see Figure 4). The machine must also be connected to a grounded metal permanent wiring system or to a system having an equipment-grounding con- ductor. Due to the complexity and high voltage involved, this type of installation MUST be done by a qualified electrician.

 

 

Locking

Power

Disconnect Switch

 

 

Source

Machine

 

Conduit

Conduit

Ground

 

Ground

Figure 4. Typical hardwire setup with a locking

disconnect switch.

Extension Cords (220V Only)

We do not recommend using an extension cord with this machine. If you must use an extension cord, only use it if absolutely necessary and only on a temporary basis.

Extension cords cause voltage drop, which may damage electrical components and shorten motor life. Voltage drop increases as the extension cord size gets longer and the gauge size gets smaller (higher gauge numbers indicate smaller sizes).

Any extension cord used with this machine must contain a ground wire, match the required plug and receptacle, and meet the following require- ments:

Maximum Length (Shorter is Better)

50 ft.

G0442 Minimum Gauge Size

10 AWG

G0601 Minimum Gauge Size

12 AWG

Model G0442/G0601 (Mfg Since 8/10)

-15-

Image 17
Contents HP Cyclone Dust Collector Page Table of Contents Manual Accuracy IntroductionContact Info Machine DescriptionIdentification Model G0442 shown IdentificationMachine Data Sheet Bag Information Performance Curve G0601 Machine Data Sheet Air Suction Cap CFM @1.9 in. S.P G0601 Performance Curve Safety Instructions for Machinery SafetyUnattended OPERATION. Never­ leave­ Additional Safety Instructions for Dust Collectors Availability Power SupplyFull-Load Current Rating Circuit RequirementsG0601 Circuit Requirements for 440V G0601 Circuit Requirements for 220VGrounding Instructions Grounding & Plug Requirements50 ft Extension Cords 220V OnlyG0601 440V Conversion To rewire the Model G0601 for 440V opera- tionCorrecting Phase Polarity G0601 Only Needed for Setup SetupUnpacking Description QtyInventory Collector Box Contents Figure QtyContents of Filter Boxes Figure Qty Stand Box Contents Figure QtyHardware Recognition Chart Site Considerations Bolting to Concrete Floors Using Machine MountsMounting to Shop Floor Assembly Foam tape attached to the intake Cylinder Aligning the mounting holes Tape Cyclone vacuum tube and hose Attachment Page Tip Use an adhesive to keep the seal in place Connecting the vacuum hose Model G0442/G0601 Mfg Since 8/10 Switch mounted to stand Model G0442/G0601 Mfg Since 8/10 To test run the dust collection system Test RunFor Model G0601 Only General System DesignDucting Materials Metal DuctPlastic Duct Flexible DuctDecide Who Will Design Designing Ducting SystemSketch The Shop Layout Sketch a Basic Duct LayoutMachine Approximate Determine CFM of Each MachineMachine Determining Main Line Duct DiameterMultiple Dust Ports Determining Branch Line Duct DiameterTwo Machines on Same Branch Line Total CFM Branch Line SizeDuct Approximate Dia Calculating Duct ResistanceLoss Per Foot Fitting 90˚ 45˚ Dia Elbow WyeY1785 Closest CFMSystem Grounding Operations Remote ControlControl Box Panel Metal Duct Starter Kit AccessoriesMetal Branches Metal ElbowsReducers & Adapters G6252-4 Floor Sweep G7341-5 Floor Sweep G7342-6 Floor SweepCleaning Filters MaintenanceSchedule Emptying DrumRemoving/Replacing Filter Rinsing FilterTools Needed Qty To replace the canister filterPage Troubleshooting ServiceRefer to Designing Ducting System, beginning Wiring Safety Instructions WiringModel G0442 G0442 Wiring DiagramModel G0601 G0601 Wiring DiagramMain PartsG0442/G0601 Common Parts List G0442 Only Parts ListG0601 Only Parts List Description Page Page Comments Warranty CardBOX BELLINGHAM, WA Grizzly INDUSTRIAL, INCWarranty and Returns Warranty and ReturnsOrder Hours a DAY