Grizzly owner manual Test Run, For Model G0601 Only, To test run the dust collection system

Page 34

Test Run

When the assembly is complete, test run the dust collection system to make sure it operates prop- erly.

If, during the test run, you cannot easily locate the source of an unusual noise or vibration, stop using the machine immediately, then review the Troubleshooting on Page 49.

If you still cannot remedy a problem, contact our Tech Support at (570) 546-9663 for assistance.

To test run the dust collection system:

1.Make sure you have read the safety instruc- tions at the beginning of the manual and that the machine is set up properly.

2.Make sure all tools and objects used during setup are cleared away from the machine.

3.Review the Circuit Requirements section beginning on Page 13 and connect the machine to the power source.

4.Flip the main power switch at the lower left hand corner of the control box to the ON ("l") position to enable power to the switch.

5.Press the ON/OFF button to turn the machine ON. Make sure your hand stays poised over the switch in case you need to quickly turn the machine OFF.

6.Listen and watch for abnormal noises or actions. The machine should run smoothly with little or no vibration or rubbing noises.

—If you suspect any problems, immedi- ately turn the machine OFF, then discon- nect the machine from power. Refer to

Troubleshooting on Page 49 to identify and fix any problems.

—If you cannot solve the problem with the use of the Troubleshooting guide, contact our Tech Support at (570) 546-9663 for assistance.

7.Press the TIMER button on the control box and cycle through each of the times to make sure the indicators light.

8.Press the TIMER button on the remote con- trol and cycle through the times in the same manner as Step 7.

9.Toggle the ON/OFF button on both the con- trol box and the remote control to make sure they are working properly.

If any part of your body contacts the spin- ning impeller, severe cutting or amputation injuries will occur. Always keep yourself and tools away from the impeller when the machine is connected to power.

For Model G0601 Only

The Model G0601 uses a 3-phase motor. For proper operation, the impeller inside the blow- er housing must rotate counterclockwise when viewed from above. Since the motor and impeller are directly connected, you must verify that the motor rotates in the correct direction.

10.Use a ladder to safely observe the motor fan through the top motor cover as another per- son turns the machine ON and OFF.

—If the motor fan rotates counterclockwise when viewed from above, the rotation direction is correct.

—If the motor fan rotates clockwise when viewed from above, the rotation direction is incorrect and the motor is wired out-of- phase. Perform the Correcting Phase Polarity procedure on Page 17 to correctly wire the machine to the power source so that the motor and impeller spin counter- clockwise when viewed from above.

-32-

Model G0442/G0601 (Mfg Since 8/10)

Image 34
Contents HP Cyclone Dust Collector Page Table of Contents Contact Info IntroductionManual Accuracy Machine DescriptionIdentification Identification Model G0442 shownMachine Data Sheet Bag Information Performance Curve G0601 Machine Data Sheet Air Suction Cap CFM @1.9 in. S.P G0601 Performance Curve Safety Safety Instructions for MachineryUnattended OPERATION. Never­ leave­ Additional Safety Instructions for Dust Collectors Full-Load Current Rating Power SupplyAvailability Circuit RequirementsGrounding Instructions G0601 Circuit Requirements for 220VG0601 Circuit Requirements for 440V Grounding & Plug RequirementsExtension Cords 220V Only 50 ftTo rewire the Model G0601 for 440V opera- tion G0601 440V ConversionCorrecting Phase Polarity G0601 Only Unpacking SetupNeeded for Setup Description QtyCollector Box Contents Figure Qty InventoryStand Box Contents Figure Qty Contents of Filter Boxes Figure QtyHardware Recognition Chart Site Considerations Mounting to Shop Floor Using Machine MountsBolting to Concrete Floors Assembly Foam tape attached to the intake Cylinder Aligning the mounting holes Tape Cyclone vacuum tube and hose Attachment Page Tip Use an adhesive to keep the seal in place Connecting the vacuum hose Model G0442/G0601 Mfg Since 8/10 Switch mounted to stand Model G0442/G0601 Mfg Since 8/10 For Model G0601 Only Test RunTo test run the dust collection system Ducting Materials System DesignGeneral Metal DuctFlexible Duct Plastic DuctSketch The Shop Layout Designing Ducting SystemDecide Who Will Design Sketch a Basic Duct LayoutDetermine CFM of Each Machine Machine ApproximateDetermining Main Line Duct Diameter MachineTwo Machines on Same Branch Line Determining Branch Line Duct DiameterMultiple Dust Ports Total CFM Branch Line SizeLoss Per Foot Calculating Duct ResistanceDuct Approximate Dia Fitting 90˚ 45˚ Dia Elbow WyeYClosest CFM 1785System Grounding Remote Control OperationsControl Box Panel Accessories Metal Duct Starter KitReducers & Adapters Metal ElbowsMetal Branches G6252-4 Floor Sweep G7341-5 Floor Sweep G7342-6 Floor SweepSchedule MaintenanceCleaning Filters Emptying DrumTools Needed Qty Rinsing FilterRemoving/Replacing Filter To replace the canister filterPage Service TroubleshootingRefer to Designing Ducting System, beginning Wiring Wiring Safety InstructionsG0442 Wiring Diagram Model G0442G0601 Wiring Diagram Model G0601Parts MainG0601 Only Parts List G0442 Only Parts ListG0442/G0601 Common Parts List Description Page Page Warranty Card CommentsGrizzly INDUSTRIAL, INC BOX BELLINGHAM, WAWarranty and Returns Warranty and ReturnsOrder Hours a DAY