Grizzly owner manual Correcting Phase Polarity G0601 Only

Page 19

Correcting Phase Polarity (G0601 Only)

This subsection is only provided for troubleshoot- ing. If you discover during the test run that the machine will not operate, or that the impeller spins backward, the power connections may be wired out-of-phase. Without the proper test equipment to determine the polarity of the power source legs, wiring machinery to 3-phase power may require trial-and-error. Correcting phase polarity is simply a matter of reversing the positions where two of the incoming power source wires are connected inside the control box.

NOTICE

If this machine is wired out-of-phase, the motor and impeller will spin in the wrong direction. The efficiency of the dust col- lector will be greatly reduced and will not provide the rated CFM. You must make sure the motor is spinning in the correct direction before placing the machine into full operation. Perform Step 10 of the test run on Page 32 to make sure the machine is correctly wired.

To correct phase polarity:

1.DISCONNECT MACHINE FROM POWER!

2.Open the control box and swap the connec- tions of any two incoming hot wires from the power source (see Figure 6).

 

POWER SOURCE

 

Swap Any

 

 

 

 

 

Two

A1

 

 

 

 

of These

 

 

 

 

 

 

 

 

 

Wires

1L1

3L2

5L3

NO13

 

Contactor

 

 

 

 

 

 

 

 

GROUND

 

2T1

4T2

6T3

NO14

 

 

 

 

 

 

ay

 

 

 

 

Figure 6. Wire connections to swap to correct

phase polarity.

Model G0442/G0601 (Mfg Since 8/10)

3.Secure the control box cover, then re-connect the machine to power.

4.Perform Step 10 of the test run on Page 32 to confirm that the power connections are correct.

—If the motor and impeller are still rotating in the wrong direction, contact our Tech Support at (570) 546-9663 for assistance.

-17-

Image 19
Contents HP Cyclone Dust Collector Page Table of Contents Machine Description IntroductionManual Accuracy Contact InfoIdentification Model G0442 shown IdentificationMachine Data Sheet Bag Information Performance Curve G0601 Machine Data Sheet Air Suction Cap CFM @1.9 in. S.P G0601 Performance Curve Safety Instructions for Machinery SafetyUnattended OPERATION. Never­ leave­ Additional Safety Instructions for Dust Collectors Circuit Requirements Power SupplyAvailability Full-Load Current RatingGrounding & Plug Requirements G0601 Circuit Requirements for 220VG0601 Circuit Requirements for 440V Grounding Instructions50 ft Extension Cords 220V OnlyG0601 440V Conversion To rewire the Model G0601 for 440V opera- tionCorrecting Phase Polarity G0601 Only Description Qty SetupNeeded for Setup UnpackingInventory Collector Box Contents Figure QtyContents of Filter Boxes Figure Qty Stand Box Contents Figure QtyHardware Recognition Chart Site Considerations Mounting to Shop Floor Using Machine MountsBolting to Concrete Floors Assembly Foam tape attached to the intake Cylinder Aligning the mounting holes Tape Cyclone vacuum tube and hose Attachment Page Tip Use an adhesive to keep the seal in place Connecting the vacuum hose Model G0442/G0601 Mfg Since 8/10 Switch mounted to stand Model G0442/G0601 Mfg Since 8/10 For Model G0601 Only Test RunTo test run the dust collection system Metal Duct System DesignGeneral Ducting MaterialsPlastic Duct Flexible DuctSketch a Basic Duct Layout Designing Ducting SystemDecide Who Will Design Sketch The Shop LayoutMachine Approximate Determine CFM of Each MachineMachine Determining Main Line Duct DiameterTotal CFM Branch Line Size Determining Branch Line Duct DiameterMultiple Dust Ports Two Machines on Same Branch LineFitting 90˚ 45˚ Dia Elbow WyeY Calculating Duct ResistanceDuct Approximate Dia Loss Per Foot1785 Closest CFMSystem Grounding Operations Remote ControlControl Box Panel Metal Duct Starter Kit AccessoriesG6252-4 Floor Sweep G7341-5 Floor Sweep G7342-6 Floor Sweep Metal ElbowsMetal Branches Reducers & AdaptersEmptying Drum MaintenanceCleaning Filters ScheduleTo replace the canister filter Rinsing FilterRemoving/Replacing Filter Tools Needed QtyPage Troubleshooting ServiceRefer to Designing Ducting System, beginning Wiring Safety Instructions WiringModel G0442 G0442 Wiring DiagramModel G0601 G0601 Wiring DiagramMain PartsG0601 Only Parts List G0442 Only Parts ListG0442/G0601 Common Parts List Description Page Page Comments Warranty CardBOX BELLINGHAM, WA Grizzly INDUSTRIAL, INCWarranty and Returns Warranty and ReturnsOrder Hours a DAY