G0601 440V Conversion
The Model G0601 can be converted for 440V operation. This conversion job consists of dis- connecting the machine from the power source, replacing the control box assembly, and rewiring the motor for 440V operation.
The necessary control box (Part
All wiring changes must be inspected by a quali- fied electrician before the machine is connected to the power source. If you need help at any time during this procedure, call Grizzly Tech Support at (570)
To rewire the Model G0601 for 440V opera- tion:
1.DISCONNECT MACHINE FROM POWER!
2.Record the wire colors and connections of the four incoming power wires and the four outgoing motor wires inside the 220V control box, as illustrated in Figure 5. You can also refer to the G0601 Wiring Diagram on Page 53 for a more complete wiring illustration.
3.Disconnect these eight wires, then replace the 220V control box with the 440V control box.
4.Reconnect the wires as recorded in Step 2.
5.Rewire the motor as shown inside the motor junction cover.
Note: The reference wiring diagram on Page 53 was current at the time of printing, but always use the wiring diagram provided inside the motor junction box, as it will reflect any changes to the motor shipped with the machine.
4Incoming Power Wires
POWER SOURCE
A1 |
|
|
|
|
1L1 | 3L2 | 5L3 | NO13 |
|
Contactor |
|
|
| GROUND |
2T1 | 4T2 | 6T3 | NO14 | |
|
|
|
|
4 Outgoing | Relay | 98 | 97 | 96 | 95 |
| Overload | ||||
Motor Wires |
|
|
|
| |
|
|
|
|
|
Figure 5. Incoming and outgoing wire
connections to the control box.
Model G0442/G0601 (Mfg Since 8/10) |