Grizzly G0601 owner manual Control Box Panel

Page 45

Control Box Panel

Use the illustration of the control box panel in Figure 59 and the descriptions that follow to become familiar with the functions of the buttons on the control box.

REMOTE CONTROL

SWITCH

B

 

A

 

 

 

 

 

 

ON/OFF

2H

4H

8H

C

 

 

 

H

 

 

D

OVER

RUN POWER

 

 

 

TIMER

MAIN

F

 

E

 

 

 

SWITCH

 

 

 

 

220 VOLT

G

 

 

 

Figure 59. Control box panel.

A.Timer Indicator Lights: Turns ON when a timer setting is selected.

B.Infrared Port: Receives infrared communica- tion from the remote control.

C.ON/OFF Button: Starts/stops the dust collec- tor motor.

D.Timer Button: Cycles through the available timer settings.

E.Power Light: Indicates when there is power to the control box.

F.Run Light: Illuminates when the dust collec- tor motor is operating.

G.Main Switch: Enables/disables the power flow to the control box and must be turned ON before using ON/OFF button.

H.Overload Light: Turns ON when the dust collector is overloaded and the motor has stopped.

Note: If the overload light illuminates and the motor stops, you must turn the machine OFF and allow the motor to cool. The overload relay should reset automatically and the light will go out.

If this is a persistent problem, refer to the

Troubleshooting section on Page 49 for additional help.

Model G0442/G0601 (Mfg Since 8/10)

-43-

Image 45
Contents HP Cyclone Dust Collector Page Table of Contents Manual Accuracy IntroductionContact Info Machine DescriptionIdentification Model G0442 shown IdentificationMachine Data Sheet Bag Information Performance Curve G0601 Machine Data Sheet Air Suction Cap CFM @1.9 in. S.P G0601 Performance Curve Safety Instructions for Machinery SafetyUnattended OPERATION. Never­ leave­ Additional Safety Instructions for Dust Collectors Availability Power SupplyFull-Load Current Rating Circuit RequirementsG0601 Circuit Requirements for 440V G0601 Circuit Requirements for 220VGrounding Instructions Grounding & Plug Requirements50 ft Extension Cords 220V OnlyG0601 440V Conversion To rewire the Model G0601 for 440V opera- tionCorrecting Phase Polarity G0601 Only Needed for Setup SetupUnpacking Description QtyInventory Collector Box Contents Figure QtyContents of Filter Boxes Figure Qty Stand Box Contents Figure QtyHardware Recognition Chart Site Considerations Using Machine Mounts Mounting to Shop FloorBolting to Concrete Floors Assembly Foam tape attached to the intake Cylinder Aligning the mounting holes Tape Cyclone vacuum tube and hose Attachment Page Tip Use an adhesive to keep the seal in place Connecting the vacuum hose Model G0442/G0601 Mfg Since 8/10 Switch mounted to stand Model G0442/G0601 Mfg Since 8/10 Test Run For Model G0601 OnlyTo test run the dust collection system General System DesignDucting Materials Metal DuctPlastic Duct Flexible DuctDecide Who Will Design Designing Ducting SystemSketch The Shop Layout Sketch a Basic Duct LayoutMachine Approximate Determine CFM of Each MachineMachine Determining Main Line Duct DiameterMultiple Dust Ports Determining Branch Line Duct DiameterTwo Machines on Same Branch Line Total CFM Branch Line SizeDuct Approximate Dia Calculating Duct ResistanceLoss Per Foot Fitting 90˚ 45˚ Dia Elbow WyeY 1785 Closest CFMSystem Grounding Operations Remote ControlControl Box Panel Metal Duct Starter Kit AccessoriesMetal Branches Metal ElbowsReducers & Adapters G6252-4 Floor Sweep G7341-5 Floor Sweep G7342-6 Floor SweepCleaning Filters MaintenanceSchedule Emptying DrumRemoving/Replacing Filter Rinsing FilterTools Needed Qty To replace the canister filterPage Troubleshooting ServiceRefer to Designing Ducting System, beginning Wiring Safety Instructions WiringModel G0442 G0442 Wiring DiagramModel G0601 G0601 Wiring DiagramMain PartsG0442 Only Parts List G0601 Only Parts ListG0442/G0601 Common Parts List Description Page Page Comments Warranty CardBOX BELLINGHAM, WA Grizzly INDUSTRIAL, INCWarranty and Returns Warranty and ReturnsOrder Hours a DAY